HVAC Rated

2-ton central heat pump · LX SERIES

York YH2F24TB21

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #300 of 331 2 ton central heat pumps for cooling efficiency, and costs about $746 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
11,900 BTU/h51% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 119 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandYork
Outdoor unit modelYH2F24TB21
SeriesLX SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMay 18, 2023
Last certifiedJuly 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity22,800-24,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F20,600-22,800 BTU/h
Capacity at 17°F13,100-14,600 BTU/h
Capacity at 5°F9,600-11,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAHB30CBAN1 at the standard test temperatures, in BTU/h:

Certified matchups119 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 119 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
XAHB30CBAN1Y81E100B12LMPS116.011.78.111,700212475767
XAHB30CBAN1Y81E100B12SMPS116.011.78.111,700212475765
XAHB36DBAN1Y81E080B12SMPS116.011.78.111,400212475111
XAFB30CBAN1Y81E040A12SMPS116.011.78.111,700212475555
XAFB36DXXN1+TXVY81E040A12SMPS116.011.78.111,400212475571
XAHB36DBAN1Y81E080B12LMPS116.011.78.111,400212475113
XAHB30CBAN1Y81E040A12LMPS116.011.78.111,700212475105
XAFB36DBAN1Y81E040A12SMPS116.011.78.111,400212475575
XAFC30CBAN1Y81E080B12LMPS116.011.78.111,600212476141
XAFB30CBAN1Y81E040A12LMPS116.011.78.111,700212475559
XAHB36DBAN1Y81E040A12LMPS116.011.78.111,500212475121
XAHB36DBAN1Y81E040A12SMPS116.011.78.111,500212475119
XAFB36DBAN1Y81E100B12LMPS116.011.78.111,400212475304
XAHB30CBAN1Y81E080B12SMPS116.011.78.111,600212475547
XAHB30CBAN1Y81E040A12SMPS116.011.78.111,700212475103
XAFC30CBAN1Y81E080B12SMPS116.011.78.111,600212476139
XAHC36DBAN1Y81E100B12SMPS116.012.08.111,500212476146
XAHC36DBAN1Y81E100B12LMPS116.012.08.111,500212476147
XAHB30CBAN1Y81E080B12LMPS116.011.78.111,600212475549
XAFB36DXXN1+TXVY81E040A12LMPS116.011.78.111,400212475573
XAHC36DBAN1Y81E080B12SMPS116.012.08.111,400212475784
XAHC36DBAN1Y81E080B12LMPS116.012.08.111,400212475786
XAFB36DXXN1+TXVY81E100B12SMPS116.011.78.111,400212475297
XAFB36DXXN1+TXVY81E100B12LMPS116.011.78.111,400212475299
XAFB36DBAN1Y81E100B12SMPS116.011.78.111,400212475301
XAFB36DBAN1Y81E040A12LMPS116.011.78.111,400212475579
XAFB30CBAN1Y81E080B12LMPS116.011.78.111,600212475981
XAFB30CBAN1Y81E080B12SMPS116.011.78.111,600212475977
XAHB36DBAN1Y81E100B12SMPS116.011.78.111,500212475988
XAHB36DBAN1Y81E100B12LMPS116.011.78.111,500212475990
XAHC30CBAN1Y81E080B12LMPS116.011.78.111,600212475097
XAHC30CBAN1Y81E080B12SMPS116.011.78.111,600212475095
XAHC36DBAN1TM8Y100C16MP1116.011.78.111,000210338944
XAHC36DBAN1TM8Y080C16MP1116.011.78.111,000210338945
XAHC30CBAN1+JMET12CS2N1-16.012.08.111,100210338244
XAHC36DBAN1+JMET12CS2N1-16.012.08.110,900210340211
XAFC30CBAN1+JMET16CS2N1-16.012.08.110,600210338906
XAHC30CBAN1+JMET16CS2N1-16.012.08.111,000210339569
XAHC36DBAN1+JMET16CS2N1-16.012.08.110,800210339609
XAFC30CBAN1+JMET12CS2N1-16.012.08.110,600210340160
XAFC30CBAN1TM9E100C16MP1216.011.78.110,600210340870
XAFC30CBAN1Y82E080B12LMPS116.011.78.111,600212593816
XAHC30CBAN1Y82E080B12LMPS116.011.78.111,600212593841
XAHC36DBAN1Y82E080B12LMPS116.012.08.111,400212593843
XAFB36DXXN1+TXVY82E080B12LMPS116.011.78.111,300212593733
XAFB36DBAN1Y82E080B12LMPS116.011.78.111,300212593734
XAFB30CBAN1TM8E040A12MP1116.011.77.810,800210338237
XAFB30CBAN1TMLE040A12MP1116.011.77.810,800210338239
XAFB30CBAN1TMLE100B12MP1116.011.77.810,700210340903
XAFB30CBAN1YPLC060A12MP1316.011.77.810,700210340897
XAFB30CBAN1TM8E100B12MP1116.011.77.810,700210340901
XAFB30CBAN1TPLC060A12MP1316.011.77.810,700210340895
XAFB30CBAN1TM8E060A12MP1116.011.77.810,800210340151
XAFB30CBAN1TMLE060A12MP1116.011.77.810,800210340153
JHVTB24CBAC2N1-16.012.07.810,500210338907
XAFC30CBAN1TM8Y080C16MP1116.011.77.810,500210339542
XAFC30CBAN1TM8Y100C16MP1116.011.77.810,500210340130
XAFB30CBAN1Y82E060A12LMPS116.011.77.811,500212593873
XAFB36DXXN1+TXVY81E080B12SMPS115.211.78.111,300212476149
XAFB36DXXN1+TXVY81E080B12LMPS115.211.78.111,300212476150
Yearly running cost in 10 large cities$697-$1,758

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH2F24TB21?
The York YH2F24TB21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 119 certified matchups SEER2 ranges from 15.2-16.0.
Is the York YH2F24TB21 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the York YH2F24TB21 cost to run per year?
At its rated efficiency it costs about $697-$1,758 a year in electricity in large U.S. cities, depending on climate and local rates - for example $845 in Phoenix and $1,457 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH2F24TB21?
ENERGY STAR lists 119 certified combinations for this outdoor unit. The highest-rated ones use XAHB30CBAN1, XAHB36DBAN1, XAFB30CBAN1.
What refrigerant does the York YH2F24TB21 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $831/yrYou save $370/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH2F24TB21
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$831
Current system, per year
$1,201
You save per year
$370
Payback
24.3 years
Net after 10 years
-$5,296

Cooling $524Heating $307Electricity used: 5,191 kWhSaved vs. a minimum-efficiency heat pump: $87

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 7, 2026. How we use the data.