2-ton central heat pump · LX SERIES
York YH524E2S11
Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #301 of 331 2 ton central heat pumps for cooling efficiency, and costs about $758 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 12,700 BTU/h54% of its 47°F outputVery good · beats 85%
A good fit if…
- You want a choice of indoor units - 55 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | York |
| Outdoor unit model | YH524E2S11 |
| Series | LX SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | July 9, 2024 |
| Last certified | August 5, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 23,000-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 22,200-23,600 BTU/h |
| Capacity at 17°F | 14,200-15,400 BTU/h |
| Capacity at 5°F | 11,200-12,700 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.28 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTF30B5ACS1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CTF30B5ACS1 | Y82V080B12SMPC1 | 16.0 | 12.0 | 8.1 | 12,400 | 217444662 |
| CTU30B5XCS1+TXV | Y82V080B12SMPC1 | 16.0 | 12.0 | 8.1 | 12,400 | 217444663 |
| CTM30B5ACS1 | Y82V080B12SMPC1 | 16.0 | 12.0 | 8.1 | 12,400 | 217444664 |
| CTM30B5ACS2 | Y82V080B12SMPC1 | 16.0 | 12.0 | 8.1 | 12,400 | 218505827 |
| CTU30B5XCS2+TXV | Y82V080B12SMPC1 | 16.0 | 12.0 | 8.1 | 12,400 | 218505744 |
| CTF30B5ACS2 | Y82V080B12SMPC1 | 16.0 | 12.0 | 8.1 | 12,400 | 218505741 |
| CTM30B5ACS1 | Y82E080B12LMPS1 | 15.2 | 12.0 | 8.1 | 12,400 | 214424790 |
| CTM30B5ACS1+JMC12B2SN1 | - | 15.2 | 12.0 | 8.1 | 12,300 | 214425230 |
| CTM30B5ACS1+JME12B2SN1 | - | 15.2 | 12.0 | 8.1 | 12,300 | 214425439 |
| CTM30B5ACS1+JME08B2SN1 | - | 15.2 | 12.0 | 8.1 | 12,200 | 214425926 |
| CTM30B5ACS1 | Y81E080B12SMPS1 | 15.2 | 12.0 | 8.1 | 12,400 | 214425932 |
| CTM30B5ACS1+JMVT12BC2N1 | - | 15.2 | 12.0 | 8.1 | 12,300 | 214430027 |
| CTM30B5ACS1 | Y81E100B12SMPS1 | 15.2 | 12.0 | 8.1 | 12,500 | 214425224 |
| CTF30B5ACS1 | Y92E060B12SMPS1 | 15.2 | 11.7 | 8.1 | 12,600 | 216376675 |
| CTU30B5XCS1+TXV | Y92E080B12SMPS1 | 15.2 | 12.0 | 8.1 | 12,500 | 216376683 |
| CTU30B5XCS1+TXV | Y92E060B12SMPS1 | 15.2 | 11.7 | 8.1 | 12,600 | 216376678 |
| CTF30B5ACS1 | Y92E080B12SMPS1 | 15.2 | 12.0 | 8.1 | 12,500 | 216376680 |
| CTM30B5ACS1 | Y81E100B12LMPS1 | 15.2 | 12.0 | 8.1 | 12,500 | 216780545 |
| CTM30B5ACS1 | Y81E080B12LMPS1 | 15.2 | 12.0 | 8.1 | 12,400 | 216780626 |
| CTM30B5ACS2 | Y81E100B12LMPS1 | 15.2 | 12.0 | 8.1 | 12,500 | 218505857 |
| CTM30B5ACS2 | Y81E100B12SMPS1 | 15.2 | 12.0 | 8.1 | 12,500 | 218505853 |
| CTM30B5ACS2 | Y81E080B12LMPS1 | 15.2 | 12.0 | 8.1 | 12,400 | 218505848 |
| CTM30B5ACS2 | Y81E080B12SMPS1 | 15.2 | 12.0 | 8.1 | 12,400 | 218505845 |
| CTM30B5ACS2 | Y82E080B12LMPS1 | 15.2 | 12.0 | 8.1 | 12,400 | 218505840 |
| CTM30B5ACS2+JMC12B2SN1 | - | 15.2 | 12.0 | 8.1 | 12,300 | 218505833 |
| CTM30B5ACS2+JMVT12BC2N1 | - | 15.2 | 12.0 | 8.1 | 12,300 | 218505830 |
| CTU30B5XCS2+TXV | Y92E080B12SMPS1 | 15.2 | 12.0 | 8.1 | 12,500 | 218505825 |
| CTF30B5ACS2 | Y92E080B12SMPS1 | 15.2 | 12.0 | 8.1 | 12,500 | 218505822 |
| CTU30B5XCS2+TXV | Y92E060B12SMPS1 | 15.2 | 11.7 | 8.1 | 12,600 | 218505820 |
| CTF30B5ACS2 | Y92E060B12SMPS1 | 15.2 | 11.7 | 8.1 | 12,600 | 218505817 |
| CTM30B5ACS1+JMET08BS2N1 | - | 15.2 | 12.0 | 8.0 | 12,100 | 214430019 |
| CTM30B5ACS1+JMET12BS2N1 | - | 15.2 | 12.0 | 8.0 | 12,200 | 214430031 |
| CTM30B5ACS1 | Y91E060B12SMPS1 | 15.2 | 11.7 | 8.0 | 12,600 | 214605011 |
| CTM30B5ACS1 | Y91E080B12SMPS1 | 15.2 | 12.0 | 8.0 | 12,300 | 214605010 |
| CTM30B5ACS1 | Y92E060B12SMPS1 | 15.2 | 11.7 | 8.0 | 12,700 | 216438488 |
| CTM30B5ACS1 | Y92E080B12SMPS1 | 15.2 | 12.0 | 8.0 | 12,500 | 216438489 |
| CTM30B5ACS2 | Y92E080B12SMPS1 | 15.2 | 12.0 | 8.0 | 12,500 | 218505860 |
| CTM30B5ACS2 | Y91E060B12SMPS1 | 15.2 | 11.7 | 8.0 | 12,600 | 218505850 |
| CTM30B5ACS2 | Y91E080B12SMPS1 | 15.2 | 12.0 | 8.0 | 12,300 | 218505843 |
| CTM30B5ACS2 | Y92E060B12SMPS1 | 15.2 | 11.7 | 8.0 | 12,700 | 218505836 |
| CTM30B5ACS2+JME08B2SN2 | - | 15.2 | 12.0 | 8.0 | 12,100 | 218636754 |
| CTM30B5ACS2+JME12B2SN2 | - | 15.2 | 12.0 | 8.0 | 12,200 | 218636751 |
| JHC24B5AC2SS1 | - | 15.2 | 11.7 | 7.8 | 12,500 | 214425099 |
| JHE24B5AC2SS1 | - | 15.2 | 12.0 | 7.8 | 11,200 | 214424696 |
| CTF30B5ACS1+JMVT12BC2N1 | - | 15.2 | 11.7 | 7.8 | 12,300 | 214425756 |
| CTF30B5ACS1+JME12B2SN1 | - | 15.2 | 12.0 | 7.8 | 11,800 | 214425928 |
| CTF30B5ACS1+JMC12B2SN1 | - | 15.2 | 11.7 | 7.8 | 11,700 | 214424785 |
| CTU30B5XCS1+JMVT12BC2N1+TXV | - | 15.2 | 11.7 | 7.8 | 12,300 | 214807636 |
| CTU30B5XCS1+JMC12B2SN1+TXV | - | 15.2 | 11.7 | 7.8 | 11,700 | 214807654 |
| CTU30B5XCS1+JME12B2SN1+TXV | - | 15.2 | 12.0 | 7.8 | 11,800 | 214807655 |
| JHE24B5AC2SS2 | - | 15.2 | 12.0 | 7.8 | 11,200 | 218456704 |
| CTU30B5XCS2+JMVT12BC2N1+TXV | - | 15.2 | 11.7 | 7.8 | 12,300 | 218505815 |
| CTF30B5ACS2+JMVT12BC2N1 | - | 15.2 | 11.7 | 7.8 | 12,300 | 218505813 |
| CTU30B5XCS2+JMC12B2SN1+TXV | - | 15.2 | 11.7 | 7.8 | 11,700 | 218505768 |
| CTF30B5ACS2+JMC12B2SN1 | - | 15.2 | 11.7 | 7.8 | 11,700 | 218505765 |
Yearly running cost in 10 large cities
- Phoenix, AZ$851/yr
- Miami, FL$698/yr
- Houston, TX$762/yr
- Atlanta, GA$758/yr
- Los Angeles, CA$735/yr
- New York, NY$1,795/yr
- Chicago, IL$1,455/yr
- Denver, CO$1,207/yr
- Seattle, WA$740/yr
- Minneapolis, MN$1,493/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the York YH524E2S11?
- The York YH524E2S11 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 55 certified matchups SEER2 ranges from 15.2-16.0.
- Is the York YH524E2S11 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the York YH524E2S11 cost to run per year?
- At its rated efficiency it costs about $698-$1,795 a year in electricity in large U.S. cities, depending on climate and local rates - for example $851 in Phoenix and $1,493 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the York YH524E2S11?
- ENERGY STAR lists 55 certified combinations for this outdoor unit. The highest-rated ones use CTF30B5ACS1, CTU30B5XCS1+TXV, CTM30B5ACS1.
- What refrigerant does the York YH524E2S11 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- WeatherKing WP15AZ24AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Frigidaire FSH4BF5M2SX24K16.0 SEER2 · 8.0 HSPF2
- Trane 5HPL5024A1000AA · cold climate16.0 SEER2 · 8.1 HSPF2
- Maytag PSH4BF5M2SX24K16.0 SEER2 · 8.0 HSPF2
- Thermal Zone TZPLAD1524AJN · cold climate16.0 SEER2 · 8.1 HSPF2
- NORDYNE SH4BF5M2SX24K16.0 SEER2 · 8.0 HSPF2
- RUSSELL SP15AZ24AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Bryant GH7TAN424**AA16.0 SEER2 · 7.8 HSPF2
See all 331 2 ton central heat pumps, ranked