HVAC Rated

5-ton central heat pump · F-Series Plus

Friedrich FRP17AY60AJVC

Average cooling efficiency and very good heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #36 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,637 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
10.5 Cooling efficiency on a 95°F day
Below average · beats 17%
Heat at 5°F
45,500 BTU/h80% of its 47°F output
Below average · beats 39%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 45,500 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 97 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandFriedrich
Outdoor unit modelFRP17AY60AJVC
SeriesF-Series Plus
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceSeptember 26, 2025
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 16.0-17.0)
EER2Efficiency at 95°F outdoors9.8-10.5
Cooling capacity56,000-57,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.5
Capacity at 47°F56,000-57,000 BTU/h
Capacity at 17°F49,000-50,000 BTU/h
Capacity at 5°F39,500-45,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00
ENERGY STAR cold climateYes
Heating output as it gets colder80% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TCFY6024STANM at the standard test temperatures, in BTU/h:

Certified matchups97 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 97 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TCFY6024STANM · cold climateFR802V1505A24UHS17.010.59.545,000218328387
TCFY6024STANM · cold climateFR802V1505A24UHN17.010.59.545,000218328386
TCFY6024STANM · cold climateFR802V1255A24UHS17.010.59.545,000218328385
TCFY6024STANM · cold climateFR802V1255A24UHN17.010.59.545,000218328384
TCFY6024STANM · cold climateFR802V1255A24DZS17.010.09.545,000218328383
TCFY6024STANM · cold climateFR802V1255A24DZN17.010.09.545,000218328382
TCFY6024STANM · cold climateFR802V1005A21DZS17.010.59.545,000218328379
TCFY6024STANM · cold climateFR802V1005A21DZN17.010.59.545,000218328378
TCFY6024STANM · cold climateFR801V1505A24UHS17.010.59.545,000218328373
TCFY6024STANM · cold climateFR801V1505A24UHN17.010.59.545,000218328372
TCFY6024STANM · cold climateFR801V1255A24UHS17.010.59.545,000218328371
TCFY6024STANM · cold climateFR801V1255A24UHN17.010.59.545,000218328370
TCFY6024STANM · cold climateFR801V1255A24DZS17.010.09.545,000218328369
TCFY6024STANM · cold climateFR801V1255A24DZN17.010.09.545,000218328368
TCFY6024STANM · cold climateFR801V1005A21DZS17.010.59.545,000218328364
TCFY6024STANM · cold climateFR801V1005A21DZN17.010.59.545,000218328363
RCFY6024STANM · cold climateFR802V1505A24UHS17.010.59.545,000218328127
RCFY6024STANM · cold climateFR802V1505A24UHN17.010.59.545,000218328126
RCFY6024STANM · cold climateFR802V1255A24UHS17.010.59.545,000218328125
RCFY6024STANM · cold climateFR802V1255A24UHN17.010.59.545,000218328124
RCFY6024STANM · cold climateFR802V1255A24DZS17.010.09.545,000218328123
RCFY6024STANM · cold climateFR802V1255A24DZN17.010.09.545,000218328122
RCFY6024STANM · cold climateFR802V1005A21DZS17.010.59.545,000218328119
RCFY6024STANM · cold climateFR802V1005A21DZN17.010.59.545,000218328118
RCFY6024STANM · cold climateFR801V1505A24UHS17.010.59.545,000218328113
RCFY6024STANM · cold climateFR801V1505A24UHN17.010.59.545,000218328112
RCFY6024STANM · cold climateFR801V1255A24UHS17.010.59.545,000218328111
RCFY6024STANM · cold climateFR801V1255A24UHN17.010.59.545,000218328110
RCFY6024STANM · cold climateFR801V1255A24DZS17.010.09.545,000218328109
RCFY6024STANM · cold climateFR801V1255A24DZN17.010.09.545,000218328108
RCFY6024STANM · cold climateFR801V1005A21DZS17.010.59.545,000218328104
RCFY6024STANM · cold climateFR801V1005A21DZN17.010.59.545,000218328103
FRH2VY6024STACN · cold climate-17.010.59.544,500218159990
TCFY6024STANM · cold climateFR962V1155A24M4S16.010.09.545,500218328403
TCFY6024STANM · cold climateFR962V1005A21M4S16.010.09.545,500218328402
TCFY6024STANM · cold climateFR962V0855A21M4S16.010.09.545,500218328401
TCFY6024STANM · cold climateFR951V1155A24M4S16.010.09.545,500218328399
TCFY6024STANM · cold climateFR951V1005A21UHU16.010.09.545,500218328398
TCFY6024STANM · cold climateFR951V1005A21M4U16.010.09.545,500218328397
TCFY6024STANM · cold climateFR951V1005A21M4S16.010.09.545,500218328396
TCFY6024STANM · cold climateFR951V0855A21M4S16.010.09.545,500218328395
TCFY6024STANM · cold climateFR951V0705A21UHU16.010.09.545,500218328394
TCFY6024STANM · cold climateFR951V0705A21M4U16.010.09.545,500218328393
TCFY6024STANM · cold climateFR921V1155A24M4S16.010.09.545,500218328391
TCFY6024STANM · cold climateFR921V1005A21M4S16.010.09.545,500218328390
TCFY6024STANM · cold climateFR921V0855A21M4S16.010.09.545,500218328389
TCFY6024STANM · cold climateFR802V1005A21UHS16.010.09.545,000218328381
TCFY6024STANM · cold climateFR802V1005A21UHN16.010.09.545,000218328380
TCFY6024STANM · cold climateFR802V0755A21UHS16.010.09.545,500218328377
TCFY6024STANM · cold climateFR802V0755A21UHN16.010.09.545,500218328376
TCFY6024STANM · cold climateFR802V0755A21DZS16.010.09.545,500218328375
TCFY6024STANM · cold climateFR802V0755A21DZN16.010.09.545,500218328374
TCFY6024STANM · cold climateFR801V1005A21UHU16.010.09.545,500218328367
TCFY6024STANM · cold climateFR801V1005A21UHS16.010.09.545,000218328366
TCFY6024STANM · cold climateFR801V1005A21UHN16.010.09.545,000218328365
TCFY6024STANM · cold climateFR801V0755A21UHS16.010.09.545,500218328362
TCFY6024STANM · cold climateFR801V0755A21UHN16.010.09.545,500218328361
TCFY6024STANM · cold climateFR801V0755A21DZS16.010.09.545,500218328360
TCFY6024STANM · cold climateFR801V0755A21DZN16.010.09.545,500218328359
RCFY6024STANM · cold climateFR962V1155A24M4S16.010.09.545,500218328143
Yearly running cost in 10 large cities$1,557-$3,837

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FRP17AY60AJVC?
The Friedrich FRP17AY60AJVC is rated at up to 17.0 SEER2 and 10.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 97 certified matchups SEER2 ranges from 16.0-17.0.
Is the Friedrich FRP17AY60AJVC good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 45,500 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Friedrich FRP17AY60AJVC cost to run per year?
At its rated efficiency it costs about $1,557-$3,837 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,874 in Phoenix and $3,171 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FRP17AY60AJVC?
ENERGY STAR lists 97 certified combinations for this outdoor unit. The highest-rated ones use TCFY6024STANM, RCFY6024STANM, FRH2VY6024STACN.
What refrigerant does the Friedrich FRP17AY60AJVC use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,836/yrYou save $1,077/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FRP17AY60AJVC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,836
Current system, per year
$2,913
You save per year
$1,077
Payback
19.5 years
Net after 10 years
-$10,227

Cooling $1,170Heating $666Electricity used: 11,475 kWhSaved vs. a minimum-efficiency heat pump: $399

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.