HVAC Rated

5-ton central heat pump · Mainline 18 SEER2 HP

Kenmore (C,H,T)5H8T60*K*AAA

Average cooling efficiency and below average heating efficiency for a 5-ton central heat pump, but not rated for cold climates.

Ranks #33 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,743 a year to run in a mixed climate like Atlanta.

SEER2
17.5 Cooling efficiency over a season
Average · beats 58%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
31,800 BTU/h53% of its 47°F output
Excellent · beats 93%

A good fit if…

  • You want a choice of indoor units - 84 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandKenmore
Outdoor unit model(C,H,T)5H8T60*K*AAA
SeriesMainline 18 SEER2 HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.5 (range 15.5-17.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity54,000-57,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F56,500-60,000 BTU/h
Capacity at 17°F36,200-38,500 BTU/h
Capacity at 5°F29,600-31,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.18-2.36
ENERGY STAR cold climateNo
Heating output as it gets colder53% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTMA5B60L0D at the standard test temperatures, in BTU/h:

Certified matchups84 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 84 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FTMA5B60L0D-17.513.08.130,200216152731
FCMA5B60L0D*+WALLCON-17.512.58.030,200216349388
EA*5X61M24A*96VTN1002122B*16.512.08.129,800216348900
EA*5X61M21A*80VSL1102122B*16.512.08.130,000216348388
EA*5X61M24A*80VSL1102122B*16.512.08.129,800216348684
EA*5X61M24A*80VTL1102122B*16.512.08.130,000216348756
EA*5X61M21A*96VTN1002122B*16.512.08.130,000216348580
EA*5X61M24A*95MSU1002122A*16.512.07.830,200216348852
EA*5X61M21A*80MSU0802120A*16.512.07.829,800216348404
EA*5X61M21A*80VTL1102122B*16.512.07.830,000216348460
EA*5X61M24A*80VSL1352422B*16.512.07.830,000216348692
EA*5X61M24A*80MSU0802120A*16.512.07.829,800216348700
EA*5X61M24A*80MSU1002120A*16.512.07.830,200216348708
EA*5X60M24A*80MSU0802120A*16.512.07.829,600216348060
EA*5X61M24AOLV154F20A16.511.77.830,400216348916
EA*5X61M21A*95MSU1002122A*16.512.07.830,200216348540
EVM5X61M24A*80MSU0802120A*16.011.78.531,600216346636
EVM5X61M24A*96VTN1002122B*16.011.78.531,600216346828
EVD5X61M24A*80MSU0802120A*16.011.78.531,600216347756
EVM5X60M21A*80VSL1102122B*16.012.08.130,000216346076
EVM5X60M21A*80MSU0601716A*16.011.78.130,000216346084
EVM5X60M21A*80MSU0802120A*16.012.08.129,800216346092
EVD5X61M21A*80VTL0902120B*16.011.78.131,000216347532
EVM5X60M21A*80MSU1002120A*16.011.78.130,400216346100
EVM5X60M21A*80VTL1102122B*16.011.78.130,000216346148
EVD5X61M21A*96VTN1002122B*16.011.78.130,800216347660
EVD5X61M21A*95MSU1002120A*16.011.78.131,400216347612
EVD5X61M21A*95MSU1002122A*16.011.78.131,000216347620
EVD5X60M21A*80VSL1102122B*16.011.78.130,400216346948
EVD5X60M21A*80MSU0802120A*16.011.78.130,400216346964
EVM5X60M21A*95MSU1002122A*16.011.78.130,200216346236
EVM5X60M21A*96VTN1002122B*16.011.78.130,000216346276
EVD5X60M21A*80VTL1102122B*16.011.78.130,400216347012
EVD5X60M21A*96VTN1002122B*16.011.78.130,200216347132
EVD5X61M21A*80VSL0902120B*16.011.78.131,000216347476
EVD5X61M21A*80MSU0802120A*16.012.08.130,600216347492
EVD5X61M21A*80MSU1002120A*16.011.78.131,000216347500
EA*5X61M24A*96VTN1202422B*16.012.08.030,200216348908
EA*5X61M24A*80VTL0902120B*16.012.08.030,000216348748
EA*5X60M24A*96VSN0802120B*16.011.77.830,000216348172
EA*5X60M24A*96VSN1202422B*16.011.77.829,800216348188
EA*5X60M24A*95MSU0802120A*16.011.77.830,000216348196
EA*5X60M24A*95MSU1002120A*16.011.77.830,000216348204
EA*5X61M24A*96VTN0802120B*16.011.77.830,200216348884
EA*5X61M24A*96VTN1002120B*16.011.77.830,200216348892
EA*5X61M21A*80VSL0902120B*16.012.07.830,000216348380
EA*5X61M21A*80MSU0601716A*16.011.77.830,400216348396
EA*5X60M24AOLV154F20A16.011.77.830,200216348276
EA*5X61M21A*80MSU1002120A*16.011.77.830,200216348412
EA*5X61M21A*80VTL0902120B*16.012.07.830,000216348452
EA*5X61M21A*96VSN0802120B*16.011.77.830,400216348500
EA*5X61M21A*96VSN1002120B*16.011.77.830,200216348508
EA*5X61M21A*95MSU0802120A*16.011.77.830,200216348524
EA*5X61M24A*80VSL0902120B*16.012.07.830,000216348676
EA*5X60M24A*80VTL0902120B*16.011.77.829,800216348108
EA*5X60M24A*80VTL1102122B*16.011.77.829,800216348116
EA*5X61M24A*96VSN0802120B*16.011.77.830,200216348812
EA*5X61M24A*96VSN1002120B*16.011.77.830,200216348820
EA*5X61M24A*96VSN1202422B*16.012.07.830,000216348828
EA*5X61M24A*95MSU0802120A*16.011.77.830,200216348836
Yearly running cost in 10 large cities$1,494-$4,218

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Kenmore (C,H,T)5H8T60*K*AAA?
The Kenmore (C,H,T)5H8T60*K*AAA is rated at up to 17.5 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 84 certified matchups SEER2 ranges from 15.5-17.5.
Is the Kenmore (C,H,T)5H8T60*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
How much does the Kenmore (C,H,T)5H8T60*K*AAA cost to run per year?
At its rated efficiency it costs about $1,494-$4,218 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,872 in Phoenix and $3,548 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Kenmore (C,H,T)5H8T60*K*AAA?
ENERGY STAR lists 84 certified combinations for this outdoor unit. The highest-rated ones use FTMA5B60L0D, FCMA5B60L0D*+WALLCON, EA*5X61M24A.
What refrigerant does the Kenmore (C,H,T)5H8T60*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,874/yrYou save $1,020/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Kenmore (C,H,T)5H8T60*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,874
Current system, per year
$2,894
You save per year
$1,020
Payback
20.6 years
Net after 10 years
-$10,795

Cooling $1,116Heating $758Electricity used: 11,712 kWhSaved vs. a minimum-efficiency heat pump: $351

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.