HVAC Rated

5-ton central heat pump · Mainline 18 SEER2 HP

Heil H5H8T60*K*AAA

Average cooling efficiency and below average heating efficiency for a 5-ton central heat pump, but not rated for cold climates.

Ranks #31 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,743 a year to run in a mixed climate like Atlanta.

SEER2
17.5 Cooling efficiency over a season
Average · beats 58%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
31,800 BTU/h53% of its 47°F output
Excellent · beats 93%

A good fit if…

  • You want a choice of indoor units - 255 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandHeil
Also sold asArcoaire, Airquest, Comfortmaker, Day & Night, Keeprite
Outdoor unit modelH5H8T60*K*AAA
SeriesMainline 18 SEER2 HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.5 (range 15.5-17.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity54,000-58,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F56,500-61,500 BTU/h
Capacity at 17°F36,200-38,500 BTU/h
Capacity at 5°F29,600-31,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.18-2.36
ENERGY STAR cold climateNo
Heating output as it gets colder53% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTMA5B60L0D at the standard test temperatures, in BTU/h:

Certified matchups255 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 255 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FTMA5B60L0D-17.513.08.130,200216151899
FTMA5B60L0D-17.513.08.130,200216152721
FTMA5B60L0D-17.513.08.130,200216152718
QFVA5D6021X-17.512.08.131,400218695629
QFVA5D6021X-17.512.08.131,400218695628
QFVA5D6021X-17.512.08.131,400218695627
FCMA5B60L0D*+WALLCON-17.512.58.030,200216349382
FCMA5B60L0D*+WALLCON-17.512.58.030,200216349383
FCMA5B60L0D*+WALLCON-17.512.58.030,200216349384
EA*5X61M24A*96VTN1002122B*16.512.08.129,800216348894
EA*5X61M24A*96VTN1002122B*16.512.08.129,800216348896
EA*5X61M24A*96VTN1002122B*16.512.08.129,800216348895
EA*5X61M21A*80VSL1102122B*16.512.08.130,000216348382
EA*5X61M21A*80VSL1102122B*16.512.08.130,000216348383
EA*5X61M21A*80VSL1102122B*16.512.08.130,000216348384
EA*5X61M24A*80VSL1102122B*16.512.08.129,800216348678
EA*5X61M24A*80VSL1102122B*16.512.08.129,800216348680
EA*5X61M24A*80VSL1102122B*16.512.08.129,800216348679
EA*5X61M24A*80VTL1102122B*16.512.08.130,000216348750
EA*5X61M24A*80VTL1102122B*16.512.08.130,000216348751
EA*5X61M24A*80VTL1102122B*16.512.08.130,000216348752
EA*5X61M21A*96VTN1002122B*16.512.08.130,000216348574
EA*5X61M21A*96VTN1002122B*16.512.08.130,000216348575
EA*5X61M21A*96VTN1002122B*16.512.08.130,000216348576
EA*5X61M24AOLV154F20A16.511.77.830,400216348910
EA*5X61M24AOLV154F20A16.511.77.830,400216348911
EA*5X61M24AOLV154F20A16.511.77.830,400216348912
EA*5X61M21A*80MSU0802120A*16.512.07.829,800216348398
EA*5X61M21A*80MSU0802120A*16.512.07.829,800216348399
EA*5X61M21A*80MSU0802120A*16.512.07.829,800216348400
EA*5X61M21A*80VTL1102122B*16.512.07.830,000216348454
EA*5X61M21A*80VTL1102122B*16.512.07.830,000216348455
EA*5X61M21A*80VTL1102122B*16.512.07.830,000216348456
EA*5X61M24A*80VSL1352422B*16.512.07.830,000216348686
EA*5X61M24A*80VSL1352422B*16.512.07.830,000216348687
EA*5X61M24A*80VSL1352422B*16.512.07.830,000216348688
EA*5X61M24A*80MSU0802120A*16.512.07.829,800216348694
EA*5X61M24A*80MSU0802120A*16.512.07.829,800216348695
EA*5X61M24A*80MSU0802120A*16.512.07.829,800216348696
EA*5X61M24A*80MSU1002120A*16.512.07.830,200216348702
EA*5X61M24A*80MSU1002120A*16.512.07.830,200216348704
EA*5X61M24A*80MSU1002120A*16.512.07.830,200216348703
EA*5X61M24A*95MSU1002122A*16.512.07.830,200216348846
EA*5X61M24A*95MSU1002122A*16.512.07.830,200216348847
EA*5X61M24A*95MSU1002122A*16.512.07.830,200216348848
EA*5X60M24A*80MSU0802120A*16.512.07.829,600216348054
EA*5X60M24A*80MSU0802120A*16.512.07.829,600216348055
EA*5X60M24A*80MSU0802120A*16.512.07.829,600216348056
EA*5X61M21A*95MSU1002122A*16.512.07.830,200216348534
EA*5X61M21A*95MSU1002122A*16.512.07.830,200216348535
EA*5X61M21A*95MSU1002122A*16.512.07.830,200216348536
EVM5X61M24A*80MSU0802120A*16.011.78.531,600216346630
EVM5X61M24A*80MSU0802120A*16.011.78.531,600216346631
EVM5X61M24A*80MSU0802120A*16.011.78.531,600216346632
EVM5X61M24A*96VTN1002122B*16.011.78.531,600216346822
EVM5X61M24A*96VTN1002122B*16.011.78.531,600216346823
EVM5X61M24A*96VTN1002122B*16.011.78.531,600216346824
EVD5X61M24A*80MSU0802120A*16.011.78.531,600216347750
EVD5X61M24A*80MSU0802120A*16.011.78.531,600216347751
EVD5X61M24A*80MSU0802120A*16.011.78.531,600216347752
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Heil H5H8T60*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,494-$4,218

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Heil H5H8T60*K*AAA?
The Heil H5H8T60*K*AAA is rated at up to 17.5 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 255 certified matchups SEER2 ranges from 15.5-17.5.
Is the Heil H5H8T60*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
How much does the Heil H5H8T60*K*AAA cost to run per year?
At its rated efficiency it costs about $1,494-$4,218 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,872 in Phoenix and $3,548 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Heil H5H8T60*K*AAA the same as the Comfortmaker C5H8T60*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Heil H5H8T60*K*AAA?
ENERGY STAR lists 255 certified combinations for this outdoor unit. The highest-rated ones use FTMA5B60L0D, QFVA5D6021X, FCMA5B60L0D*+WALLCON.
What refrigerant does the Heil H5H8T60*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,874/yrYou save $1,020/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H8T60*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,874
Current system, per year
$2,894
You save per year
$1,020
Payback
20.6 years
Net after 10 years
-$10,795

Cooling $1,116Heating $758Electricity used: 11,712 kWhSaved vs. a minimum-efficiency heat pump: $351

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.