HVAC Rated

5-ton central heat pump · 2-STAGE 18 SEER HP

Carrier GH8TAN560**AA

Average cooling efficiency and below average heating efficiency for a 5-ton central heat pump, but not rated for cold climates.

Ranks #29 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,743 a year to run in a mixed climate like Atlanta.

SEER2
17.5 Cooling efficiency over a season
Average · beats 58%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
31,800 BTU/h53% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 258 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandCarrier
Also sold asBryant
Outdoor unit modelGH8TAN560**AA
Series2-STAGE 18 SEER HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 4, 2024
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.5 (range 15.5-17.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity54,000-58,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F56,500-61,500 BTU/h
Capacity at 17°F36,200-38,500 BTU/h
Capacity at 5°F29,600-31,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder53% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FG5ANBD60L at the standard test temperatures, in BTU/h:

Certified matchups258 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 258 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FG5ANBD60L-17.513.08.130,200215560737
PF5TNBD60L-17.513.08.130,200215560738
FG5ANBD60L-17.513.08.130,200215560732
FT5ANBD60L-17.513.08.130,200215560731
FT5ANBD60L-17.513.08.130,200215560736
FT5BD6021X-17.512.08.131,400218695459
FT5BD6021X-17.512.08.131,400218695457
CAA**6121AM59TP6C100V21**2216.512.08.130,000215629966
CAA**6121AM926TC66100V21***16.512.08.130,000215629968
CAA**6124AM58SP*B110V21**2216.512.08.129,800215630020
CAA**6124AM82*SB66110V21***16.512.08.129,800215630022
CAA**6121AM58SP*B110V21**2216.512.08.130,000215629575
CAA**6121AM82*SB66110V21***16.512.08.130,000215629577
CAA**6124AM88*TB60090C21***16.512.08.130,200215630100
CAA**6124AM58TN*B090C21**2016.512.08.130,200215630098
CAA**6124AM58TP*B110V21**2216.512.08.130,000215630156
CAA**6124AM82*TB66110V21***16.512.08.130,000215630158
CAA**6124AM58TP*B135V24**2216.512.08.130,000215630174
CAA**6124AM82*TB66135V24***16.512.08.130,000215630176
CAA**6124AM59MN7C100C21**2216.512.08.130,400215630238
CAA**6124AM987MC66100C21***16.512.08.130,400215630240
CAA**6124AM59TP6C100V21**2216.512.08.129,800215630435
CAA**6124AM926TC66100V21***16.512.08.129,800215630437
CAA**6024AM58SU*B080M21**2016.512.08.029,600215629086
CAA**6024AM83*SB60080M21***16.512.08.029,600215629088
CAA**6121AM59SU5B100M21**2216.512.08.030,200215629888
CAA**6121AM935SB66100M21***16.512.08.030,200215629890
CAA**6124AM58SP*B135V24**2216.512.08.030,000215630033
CAA**6124AM82*SB66135V24***16.512.08.030,000215630035
CAA**6124AM58SU*B080M21**2016.512.08.029,800215630046
CAA**6124AM83*SB60080M21***16.512.08.029,800215630048
CAA**6124AM83*SB60100M21***16.512.08.030,200215630067
CAA**6124AM58SU*B100M21**2016.512.08.030,200215630065
CAA**6121AM58SU*B080M21**2016.512.08.029,800215629607
CAA**6121AM83*SB60080M21***16.512.08.029,800215629609
CAA**6124AM88*TB60110C21***16.512.08.030,200215630114
CAA**6124AM58TN*B110C21**2016.512.08.030,200215630112
CAA**6124AM58TN*B135C24**2216.512.08.030,200215630126
CAA**6124AM88*TB66135C24***16.512.08.030,200215630128
CAA**6124AM59CU5B100C21**2216.512.08.030,000215630196
CAA**6124AM935CB66100C21***16.512.08.030,000215630198
CAA**6121AM58TN*B110C21**2016.512.08.030,400215629687
CAA**6121AM88*TB60110C21***16.512.08.030,400215629689
CAA**6121AM82*TB66110V21***16.512.08.030,000215629719
CAA**6121AM58TP*B110V21**2216.512.08.030,000215629717
CAA**6124AMOVLAAB06015416.511.78.030,400215630466
CAA**6124AMOVLAAB06015416.511.78.030,400215630468
CAA**6124AM59SU5B100M21**2216.512.08.030,200215630343
CAA**6124AM935SB66100M21***16.512.08.030,200215630345
CAA**6124AM59TP7A100V21**2216.512.08.029,800215718628
CAA**6124AM927TA66100V21***16.512.08.029,800215718630
CAA**6121AM59TP7A100V21**2216.512.08.030,000215718511
CAA**6121AM927TA66100V21***16.512.08.030,000215718513
CAA**6124AM58CU*A080C21**2016.511.77.831,400215629979
CAA**6124AM83*CA60080C21***16.511.77.831,400215629981
CVAMA6124XMA58TP*B135V24**2216.011.78.531,400215626665
CVAMA6124XMA82*TB66135V24***16.011.78.531,400215626667
CVAMA6124XMA59TP6C100V21**2216.011.78.531,600215626912
CVAMA6124XMA926TC66100V21***16.011.78.531,600215626914
CVAMA6124XMA58SP*B090V21**2016.011.78.531,800215626498
Yearly running cost in 10 large cities$1,494-$4,218

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Carrier GH8TAN560**AA?
The Carrier GH8TAN560**AA is rated at up to 17.5 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 258 certified matchups SEER2 ranges from 15.5-17.5.
Is the Carrier GH8TAN560**AA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
How much does the Carrier GH8TAN560**AA cost to run per year?
At its rated efficiency it costs about $1,494-$4,218 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,872 in Phoenix and $3,548 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Carrier GH8TAN560**AA?
ENERGY STAR lists 258 certified combinations for this outdoor unit. The highest-rated ones use FG5ANBD60L, PF5TNBD60L, FT5ANBD60L.
What refrigerant does the Carrier GH8TAN560**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,874/yrYou save $1,020/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier GH8TAN560**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,874
Current system, per year
$2,894
You save per year
$1,020
Payback
20.6 years
Net after 10 years
-$10,795

Cooling $1,116Heating $758Electricity used: 11,712 kWhSaved vs. a minimum-efficiency heat pump: $351

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.