HVAC Rated

5-ton central heat pump · PRESTIGE SERIES

Friedrich RD17AZ60AJ3N

Very good cooling efficiency and below average heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #18 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,795 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
10.0 Cooling efficiency on a 95°F day
Below average · beats 10%
Heat at 5°F
49,500 BTU/h81% of its 47°F output
Below average · beats 1%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 49,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 76 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications5 ton, R-410A
General
BrandFriedrich
Also sold asRheem, Ruud, RUSSELL, Sure
Outdoor unit modelRD17AZ60AJ3N
SeriesPRESTIGE SERIES
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableYes
On the market sinceJanuary 26, 2024
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 17.0-19.0)
EER2Efficiency at 95°F outdoors10.0
Cooling capacity55,000-55,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1
Capacity at 47°F60,000 BTU/h
Capacity at 17°F50,000-51,000 BTU/h
Capacity at 5°F48,500-49,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75
ENERGY STAR cold climateYes
Heating output as it gets colder81% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with RH3VZ6024STACN at the standard test temperatures, in BTU/h:

Certified matchups76 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 76 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
RH3VZ6024STACN · cold climate-19.010.08.148,500214097884
FRH3VZ6024STACN · cold climate-19.010.08.148,500214097885
RH3VZ6024STACN · cold climate-19.010.08.148,500214097886
RCFZ6024STANM · cold climateR951V0705A21M4S18.010.08.149,500214075356
RCFZ6024STANM · cold climateR951V0705A21M4S18.010.08.149,500214075317
RCFZ6024STANM · cold climateR951V1005A21M4S18.010.08.149,500214075339
RCFZ6024STANM · cold climateR951V1005A21M4S18.010.08.149,500214075311
RCFZ6024STANM · cold climateR951V1155A24M4S18.010.08.149,000214075316
RCFZ6024STANM · cold climateR951V1155A24M4S18.010.08.149,000214075329
RCFZ6024STANM · cold climateR962V0705A21M4S18.010.08.149,500214075399
RCFZ6024STANM · cold climateR962V0705A21M4S18.010.08.149,500214075369
RCFZ6024STANM · cold climateR962V1005A21M4S18.010.08.149,500214075391
RCFZ6024STANM · cold climateR962V1005A21M4S18.010.08.149,500214075396
RCFZ6024STANM · cold climateR962V1155A24M4S18.010.08.149,000214075388
RCFZ6024STANM · cold climateR962V1155A24M4S18.010.08.149,000214075405
RCFZ6024STANM · cold climateR97MV0855A21DHS18.010.08.149,500214075389
RCFZ6024STANM · cold climateR97MV1005A21DHS18.010.08.149,500214075404
RCFZ6024STANM · cold climateR97MV1155A24DHS18.010.08.149,500214075361
RCFZ6024STANM · cold climateR98MV0855A21UPS18.010.08.149,500214075373
RCFZ6024STANM · cold climateR98MV1155A24UPS18.010.08.149,500214075370
RCFZ6024STANM · cold climateU97MV0855A21DHS18.010.08.149,500214075364
RCFZ6024STANM · cold climateU97MV1005A21DHS18.010.08.149,500214075387
RCFZ6024STANM · cold climateU97MV1155A24DHS18.010.08.149,500214075375
RCFZ6024STANM · cold climateU98MV0855A21UPS18.010.08.149,500214075403
RCFZ6024STANM · cold climateU98MV1155A24UPS18.010.08.149,500214075380
TCFZ6024STANM · cold climateFR951V0705A21M418.010.08.149,500214075327
TCFZ6024STANM · cold climateFR951V1005A21M418.010.08.149,500214075310
TCFZ6024STANM · cold climateFR951V1005A21UHU18.010.08.149,500214075346
TCFZ6024STANM · cold climateFR951V1155A24M418.010.08.149,000214075347
TCFZ6024STANM · cold climateFR962V0705A21M418.010.08.149,500214075393
TCFZ6024STANM · cold climateFR962V1005A21M418.010.08.149,500214075376
TCFZ6024STANM · cold climateFR962V1155A24M418.010.08.149,000214075381
TCFZ6024STANM · cold climateFR97MV0855A21DH18.010.08.149,500214075367
TCFZ6024STANM · cold climateFR97MV1005A21DH18.010.08.149,500214075401
TCFZ6024STANM · cold climateFR97MV1155A24DH18.010.08.149,500214075372
TCFZ6024STANM · cold climateFR98MV0855A21UP18.010.08.149,500214075368
TCFZ6024STANM · cold climateFR98MV1155A24UP18.010.08.149,500214075402
TCFZ6024STANM · cold climateS951V0705A21M4S18.010.08.149,500214075344
TCFZ6024STANM · cold climateS951V0705A21M4S18.010.08.149,500214075350
TCFZ6024STANM · cold climateS951V1005A21M4S18.010.08.149,500214075314
TCFZ6024STANM · cold climateS951V1005A21M4S18.010.08.149,500214075313
TCFZ6024STANM · cold climateS951V1005A21UHU18.010.08.149,500214075320
TCFZ6024STANM · cold climateS951V1005A21UHU18.010.08.149,500214075324
TCFZ6024STANM · cold climateS951V1155A24M4S18.010.08.149,000214075318
TCFZ6024STANM · cold climateS951V1155A24M4S18.010.08.149,000214075325
TCFZ6024STANM · cold climateS962V0705A21M4S18.010.08.149,500214075357
TCFZ6024STANM · cold climateS962V0705A21M4S18.010.08.149,500214075363
TCFZ6024STANM · cold climateS962V1005A21M4S18.010.08.149,500214075377
TCFZ6024STANM · cold climateS962V1005A21M4S18.010.08.149,500214075385
TCFZ6024STANM · cold climateS962V1155A24M4S18.010.08.149,000214075397
TCFZ6024STANM · cold climateS962V1155A24M4S18.010.08.149,000214075406
TCFZ6024STANM · cold climateS97MV0855A21DHS18.010.08.149,500214075394
TCFZ6024STANM · cold climateS97MV0855A21DHS18.010.08.149,500214075395
TCFZ6024STANM · cold climateS97MV1005A21DHS18.010.08.149,500214075362
TCFZ6024STANM · cold climateS97MV1005A21DHS18.010.08.149,500214075359
TCFZ6024STANM · cold climateS97MV1155A24DHS18.010.08.149,500214075392
TCFZ6024STANM · cold climateS97MV1155A24DHS18.010.08.149,500214075398
TCFZ6024STANM · cold climateS98MV0855A21UPS18.010.08.149,500214075383
TCFZ6024STANM · cold climateS98MV0855A21UPS18.010.08.149,500214075384
TCFZ6024STANM · cold climateS98MV1155A24UPS18.010.08.149,500214075371
Yearly running cost in 10 large cities$1,373-$4,479

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich RD17AZ60AJ3N?
The Friedrich RD17AZ60AJ3N is rated at up to 19.0 SEER2 and 10.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 76 certified matchups SEER2 ranges from 17.0-19.0.
Is the Friedrich RD17AZ60AJ3N good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 49,500 BTU/h at 5°F with a COP of 1.75, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Friedrich RD17AZ60AJ3N cost to run per year?
At its rated efficiency it costs about $1,373-$4,479 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,804 in Phoenix and $3,828 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich RD17AZ60AJ3N?
ENERGY STAR lists 76 certified combinations for this outdoor unit. The highest-rated ones use RH3VZ6024STACN, FRH3VZ6024STACN, RCFZ6024STANM.
What refrigerant does the Friedrich RD17AZ60AJ3N use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,849/yrYou save $1,069/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich RD17AZ60AJ3N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,849
Current system, per year
$2,918
You save per year
$1,069
Payback
19.2 years
Net after 10 years
-$9,808

Cooling $1,019Heating $830Electricity used: 11,554 kWhSaved vs. a minimum-efficiency heat pump: $401

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.