HVAC Rated

24,000 BTU mini-split heat pump · Endure PRO

GE Appliances ASH124UCDD

Below average cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #285 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $655 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Below average · beats 30%
HSPF2
10.0 Heating efficiency over a season
Average · beats 43%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 9%
Heat at 5°F
22,000 BTU/h85% of its 47°F output
Below average · beats 9%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 22,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications24,000 BTU, R-410A
General
BrandGE Appliances
Also sold asHaier
Outdoor unit modelASH124UCDD
SeriesEndure PRO
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMarch 20, 2023
Last certifiedJune 9, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 16.5-21.0)
EER2Efficiency at 95°F outdoors9.5-11.0
Cooling capacity24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-10.0
Capacity at 47°F26,000 BTU/h
Capacity at 17°F17,000-17,400 BTU/h
Capacity at 5°F19,000-22,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80
ENERGY STAR cold climateYes
Heating output as it gets colder85% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ASYW24TRDF at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
ASYW24TRDF · cold climate21.011.010.022,000211744609
USYL24UCDD · cold climate19.011.08.619,000211744608
USYM24UCDD · cold climate16.59.58.120,000211727011
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the GE Appliances ASH124UCDD: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$540-$1,603

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the GE Appliances ASH124UCDD?
The GE Appliances ASH124UCDD is rated at up to 21.0 SEER2 and 11.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 16.5-21.0.
Is the GE Appliances ASH124UCDD good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 22,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the GE Appliances ASH124UCDD cost to run per year?
At its rated efficiency it costs about $540-$1,603 a year in electricity in large U.S. cities, depending on climate and local rates - for example $687 in Phoenix and $1,356 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the GE Appliances ASH124UCDD the same as the Haier 1U24LP2HD?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the GE Appliances ASH124UCDD?
ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use ASYW24TRDF, USYL24UCDD, USYM24UCDD.
What refrigerant does the GE Appliances ASH124UCDD use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $693/yrYou save $577/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump GE Appliances ASH124UCDD
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$693
Current system, per year
$1,270
You save per year
$577
Payback
15.6 years
Net after 10 years
-$3,233

Cooling $402Heating $291Electricity used: 4,334 kWhSaved vs. a minimum-efficiency heat pump: $286

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.