24,000 BTU mini-split heat pump · ASH324JCDD**
GE Appliances ASH324JCDD
Average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #195 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $616 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.0 Cooling efficiency over a seasonAverage · beats 48%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 12.8 Cooling efficiency on a 95°F dayAverage · beats 56%
- Heat at 5°F
- 10,000 BTU/h40% of its 47°F outputBelow average · beats 9%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | GE Appliances |
| Also sold as | Haier |
| Outdoor unit model | ASH324JCDD |
| Series | ASH324JCDD** |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | September 21, 2022 |
| Last certified | June 9, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.0 (range 22.0) |
| EER2Efficiency at 95°F outdoors | 12.8 |
| Cooling capacity | 22,600 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0 |
| Capacity at 47°F | 25,000 BTU/h |
| Capacity at 17°F | 16,000 BTU/h |
| Capacity at 5°F | 10,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - | 22.0 | 12.8 | 10.0 | 10,000 | 207698999 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the GE Appliances ASH324JCDD: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Haier 3U24MS2HD
Yearly running cost in 10 large cities
- Phoenix, AZ$630/yr
- Miami, FL$486/yr
- Houston, TX$566/yr
- Atlanta, GA$616/yr
- Los Angeles, CA$609/yr
- New York, NY$1,524/yr
- Chicago, IL$1,247/yr
- Denver, CO$1,045/yr
- Seattle, WA$649/yr
- Minneapolis, MN$1,297/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GE Appliances ASH324JCDD?
- The GE Appliances ASH324JCDD is rated at up to 22.0 SEER2 and 12.8 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the GE Appliances ASH324JCDD good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 24,000 BTU model.
- How much does the GE Appliances ASH324JCDD cost to run per year?
- At its rated efficiency it costs about $486-$1,524 a year in electricity in large U.S. cities, depending on climate and local rates - for example $630 in Phoenix and $1,297 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the GE Appliances ASH324JCDD the same as the Haier 3U24MS2HD?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- What refrigerant does the GE Appliances ASH324JCDD use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- Deye DW3B1-ACDC-24KR2(US) · cold climate22.0 SEER2 · 10.0 HSPF2
- Kaden KO-PSX24HP-2AAMA · cold climate22.0 SEER2 · 10.0 HSPF2
- AUX ASW-H24F8A2/*R3DI-C7 · cold climate22.0 SEER2 · 10.0 HSPF2
- Midea MOD-24HFN1AA22.0 SEER2 · 10.0 HSPF2
- AUX AFEB24HP230V1CO · cold climate22.0 SEER2 · 10.0 HSPF2
- Midea MOD32-24HFN1-MT0W22.0 SEER2 · 10.0 HSPF2
- Lennox MMLD024S6S-1P · cold climate22.0 SEER2 · 10.2 HSPF2
- TCL TMH27HDI2NAO0U25 · cold climate22.0 SEER2 · 10.0 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.