2.5-ton central heat pump · Hi-PRO HD
Hisense AUWR-36U3TW5
Excellent cooling and heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.
Ranks #15 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $827 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.5 Cooling efficiency over a seasonExcellent · beats 91%
- HSPF2
- 10.5 Heating efficiency over a seasonExcellent · beats 96%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 31,000 BTU/h97% of its 47°F outputAverage · beats 69%
A good fit if…
- You want low cooling bills - its SEER2 beats 91% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 31,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 96% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Hisense |
| Also sold as | Multi MFG |
| Outdoor unit model | AUWR-36U3TW5 |
| Series | Hi-PRO HD |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | July 24, 2024 |
| Last certified | April 22, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.5 (range 19.5) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 32,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.5 |
| Capacity at 47°F | 32,000 BTU/h |
| Capacity at 17°F | 32,000 BTU/h |
| Capacity at 5°F | 31,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.15 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with AUH-36UX3TDH3 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| AUH-36UX3TDH3 · cold climate | 19.5 | 11.7 | 10.5 | 31,000 | 214802097 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Hisense AUWR-36U3TW5: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Multi MFG MSD-36HD-B
Yearly running cost in 10 large cities
- Phoenix, AZ$934/yr
- Miami, FL$769/yr
- Houston, TX$836/yr
- Atlanta, GA$827/yr
- Los Angeles, CA$800/yr
- New York, NY$1,951/yr
- Chicago, IL$1,580/yr
- Denver, CO$1,309/yr
- Seattle, WA$802/yr
- Minneapolis, MN$1,619/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Hisense AUWR-36U3TW5?
- The Hisense AUWR-36U3TW5 is rated at up to 19.5 SEER2 and 11.7 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Hisense AUWR-36U3TW5 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 31,000 BTU/h at 5°F with a COP of 2.15, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the Hisense AUWR-36U3TW5 cost to run per year?
- At its rated efficiency it costs about $769-$1,951 a year in electricity in large U.S. cities, depending on climate and local rates - for example $934 in Phoenix and $1,619 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Hisense AUWR-36U3TW5 the same as the Multi MFG MSD-36HD-B?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Hisense AUWR-36U3TW5?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses AUH-36UX3TDH3.
- What refrigerant does the Hisense AUWR-36U3TW5 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- York YZV36B2119.5 SEER2 · 8.5 HSPF2
- Blueridge BXS5A33UC0 · cold climate19.5 SEER2 · 10.5 HSPF2
- Bryant 284ANV036*0**B · cold climate19.0 SEER2 · 9.5 HSPF2
- Arcoaire D5CSHAH33AAK · cold climate19.6 SEER2 · 10.5 HSPF2
- Innovair TOV36H2XA · cold climate19.0 SEER2 · 9.5 HSPF2
- York YDV36E2D11 · cold climate20.0 SEER2 · 9.5 HSPF2
- UTL UCHA-30HFDCSN4 · cold climate18.6 SEER2 · 9.3 HSPF2
- Luxaire XDV36E2D11 · cold climate20.0 SEER2 · 9.5 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 22, 2026. How we use the data.