HVAC Rated

2.5-ton central heat pump · Hi ULTRA HD-Coil

Hisense AUWR-36U3SA

Below average cooling efficiency and average heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.

Ranks #162 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $908 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
9.4 Heating efficiency over a season
Average · beats 64%
EER2
11.3 Cooling efficiency on a 95°F day
Below average · beats 29%
Heat at 5°F
24,200 BTU/h81% of its 47°F output
Average · beats 53%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,200 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandHisense
Outdoor unit modelAUWR-36U3SA
SeriesHi ULTRA HD-Coil
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceOctober 25, 2023
Last certifiedJanuary 29, 2025
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.5)
EER2Efficiency at 95°F outdoors11.3
Cooling capacity30,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.4
Capacity at 47°F30,000 BTU/h
Capacity at 17°F23,000 BTU/h
Capacity at 5°F24,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.08
ENERGY STAR cold climateYes
Heating output as it gets colder81% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DC37A44-210L at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
DC37A44-210L · cold climate15.511.39.424,200213411087
Yearly running cost in 10 large cities$846-$2,096

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Hisense AUWR-36U3SA?
The Hisense AUWR-36U3SA is rated at up to 15.5 SEER2 and 11.3 EER2 for cooling and up to 9.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Hisense AUWR-36U3SA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,200 BTU/h at 5°F with a COP of 2.08, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Hisense AUWR-36U3SA cost to run per year?
At its rated efficiency it costs about $846-$2,096 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,070 in Phoenix and $1,717 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Hisense AUWR-36U3SA?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses DC37A44-210L.
What refrigerant does the Hisense AUWR-36U3SA use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,039/yrYou save $508/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Hisense AUWR-36U3SA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,039
Current system, per year
$1,547
You save per year
$508
Payback
22.6 years
Net after 10 years
-$6,419

Cooling $681Heating $357Electricity used: 6,492 kWhSaved vs. a minimum-efficiency heat pump: $148

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 29, 2025. How we use the data.