2.5-ton central heat pump · Hi ULTRA HD-Coil
Hisense AUWR-36U3SA
Below average cooling efficiency and average heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.
Ranks #162 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $908 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.5 Cooling efficiency over a seasonBelow average · beats 15%
- HSPF2
- 9.4 Heating efficiency over a seasonAverage · beats 64%
- EER2
- 11.3 Cooling efficiency on a 95°F dayBelow average · beats 29%
- Heat at 5°F
- 24,200 BTU/h81% of its 47°F outputAverage · beats 53%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,200 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Hisense |
| Outdoor unit model | AUWR-36U3SA |
| Series | Hi ULTRA HD-Coil |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 25, 2023 |
| Last certified | January 29, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.5 (range 15.5) |
| EER2Efficiency at 95°F outdoors | 11.3 |
| Cooling capacity | 30,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.4 |
| Capacity at 47°F | 30,000 BTU/h |
| Capacity at 17°F | 23,000 BTU/h |
| Capacity at 5°F | 24,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.08 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DC37A44-210L at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| DC37A44-210L · cold climate | 15.5 | 11.3 | 9.4 | 24,200 | 213411087 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,070/yr
- Miami, FL$904/yr
- Houston, TX$958/yr
- Atlanta, GA$908/yr
- Los Angeles, CA$870/yr
- New York, NY$2,096/yr
- Chicago, IL$1,687/yr
- Denver, CO$1,391/yr
- Seattle, WA$846/yr
- Minneapolis, MN$1,717/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Hisense AUWR-36U3SA?
- The Hisense AUWR-36U3SA is rated at up to 15.5 SEER2 and 11.3 EER2 for cooling and up to 9.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Hisense AUWR-36U3SA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,200 BTU/h at 5°F with a COP of 2.08, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Hisense AUWR-36U3SA cost to run per year?
- At its rated efficiency it costs about $846-$2,096 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,070 in Phoenix and $1,717 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Hisense AUWR-36U3SA?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses DC37A44-210L.
- What refrigerant does the Hisense AUWR-36U3SA use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- WeatherMaker PH5SAN531**AB16.0 SEER2 · 8.0 HSPF2
- Carrier 27SCA531A**3015.5 SEER2 · 8.0 HSPF2
- Tempstar T5H6S31*K*AAA16.0 SEER2 · 8.0 HSPF2
- Midea MDV-V30WMN10T-H · cold climate15.3 SEER2 · 8.5 HSPF2
- Kenmore R5H5S31*K*AAA16.0 SEER2 · 8.0 HSPF2
- MDV MOD30-32HFN10-M3 · cold climate15.2 SEER2 · 8.5 HSPF2
- Heil H5H6S31*K*AAA16.0 SEER2 · 8.0 HSPF2
- TCL THH30HAI2NAF2U23 · cold climate15.2 SEER2 · 8.5 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 29, 2025. How we use the data.