HVAC Rated

2.5-ton central heat pump · LX SERIES

York YH2F30TB21

Below average cooling and heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #151 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $953 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
18,600 BTU/h54% of its 47°F output
Excellent · beats 100%

A good fit if…

  • You want a choice of indoor units - 188 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandYork
Outdoor unit modelYH2F30TB21
SeriesLX SERIES
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMay 18, 2023
Last certifiedJuly 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity28,400-30,600 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F27,000-29,200 BTU/h
Capacity at 17°F17,600-19,100 BTU/h
Capacity at 5°F13,600-18,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.02-2.76
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAFC48FXXN1+TXV at the standard test temperatures, in BTU/h:

Certified matchups188 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 188 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
XAFC48FXXN1+TXVY81E080B12LMPS116.011.78.115,700212475878
XAFB36DXXN1+TXVY81E040A12LMPS116.012.08.115,600212475157
XAFB36DXXN1+TXVY81E040A12SMPS116.012.08.115,600212475155
XAFC48FBAN1Y81E080B12LMPS116.011.78.115,700212475884
XAFC48FXXN1+TXVY81E080B12SMPS116.011.78.115,700212475876
XAFC48FBAN1Y81E080B12SMPS116.011.78.115,700212475880
XAFB36DBAN1Y81E040A12SMPS116.012.08.115,600212475159
XAFB36DBAN1Y81E100B12SMPS116.011.78.115,800212475411
XAFB36DXXN1+TXVY81E100B12SMPS116.011.78.115,800212475407
XAFB36DXXN1+TXVY81E100B12LMPS116.011.78.115,800212475409
XAFB36DBAN1Y81E100B12LMPS116.011.78.115,800212475415
XAFC48FXXN1+TXVY81E100B12SMPS116.011.78.115,800212475431
XAFC48FXXN1+TXVY81E100B12LMPS116.011.78.115,800212475433
XAFC48FBAN1Y81E100B12SMPS116.011.78.115,800212475435
XAFC48FBAN1Y81E100B12LMPS116.011.78.115,800212475439
XAFB36DBAN1Y81E040A12LMPS116.012.08.115,600212475163
XAFC36DBAN1TMLE100C16MP1116.011.78.114,500210339424
XAFC36DBAN1TL9E080C16UH1116.011.78.114,600210339436
XAFC36DBAN1TM8E100C16MP1116.011.78.114,500210339423
XAFC36DBAN1+JMVT17CC2N1-16.012.08.114,200210339438
XAFD48FBAN1TMLE080C16MP1116.011.78.114,600210340304
XAFD48FBAN1TM8E080C16MP1116.011.78.114,600210340303
XAFC36DBAN1TL8E080C16UH1116.011.78.114,500210341540
XAFC36DBAN1+JMET16CS2N1-16.012.08.114,300210341543
XAFC36DBAN1TM8V100C16MP1216.011.78.114,500210340747
XAFC36DBAN1YPLC080C16MP1316.011.78.114,500210340751
XAFC36DBAN1TPLC080C16MP1316.011.78.114,500210340749
XAFC36DBAN1TPLC100C16MP1316.011.78.114,500210340750
XAFC36DBAN1TMLV100C16MP1216.011.78.114,500210340748
XAFC36DBAN1YPLC100C16MP1316.011.78.114,500210340752
XAFC36DBAN1TL8E100C20UH1116.012.08.114,300210338109
XAFC36DBAN1+JMVT16CC2N1-16.012.08.114,200210340033
XAFC36DBAN1TM8E080C16MP1116.011.78.114,500210340024
XAFC36DBAN1TM8V080C16MP1216.011.78.114,500210340013
XAFC36DBAN1TM8E120C16MP1116.011.78.114,500210340016
XAFC36DBAN1TMLE120C16MP1116.011.78.114,500210340017
XAFC36DBAN1TMLE080C16MP1116.011.78.114,500210340025
XAFC36DBAN1+JMET12CS2N1-16.012.08.114,300210340035
XAFC36DBAN1Y82E080B12LMPS116.011.78.116,000212593820
XAFC36DBAN1Y82E080C16LMPS116.012.08.115,500212593707
XAFD48FBAN1Y82E080C16LMPS116.012.08.115,200212593709
JHVTD42FBAC2N1-16.012.08.114,000210338440
JHETC36DBAS2N1-16.012.08.114,200210340791
JHETC42FBAS2N1-16.012.08.114,400210341103
JHVTC42FBAC2N1-16.012.08.114,000210345195
XAFC48FXXN1+JMET12CS2N1+TXV-16.012.08.113,800210341100
XAFC48FXXN1+JMET16CS2N1+TXV-16.012.08.113,800210338435
XAFB36DXXN1+JMET12BS2N1+TXV-16.012.08.114,300210338121
XAFC48FXXN1+JMVT17CC2N1+TXV-16.012.08.114,200210340314
XAFC48FXXN1+JMVT16CC2N1+TXV-16.012.08.114,200210341914
XAFB36DBAN1+JMET12BS2N1-16.012.08.114,300210338122
XAFC48FBAN1+JMET16CS2N1-16.012.08.113,800210338436
JHETB36DBAS2N1-16.012.08.114,400210339447
XAFC48FBAN1+JMVT17CC2N1-16.012.08.114,200210345193
XAFC48FBAN1+JMVT16CC2N1-16.012.08.114,200210345201
XAHC36DBAN1+JMET16CS2N1-16.011.78.113,900210340790
XAFC48FBAN1+JMET12CS2N1-16.012.08.113,800210341101
XAHC36DBAN1Y82E080C16LMPS116.011.78.114,900212593795
XAFC48FXXN1+TXVY82E080C16LMPS116.012.08.115,200212593740
XAFC48FBAN1Y82E080C16LMPS116.012.08.115,200212593741
Yearly running cost in 10 large cities$880-$2,254

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH2F30TB21?
The York YH2F30TB21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 188 certified matchups SEER2 ranges from 15.2-16.0.
Is the York YH2F30TB21 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the York YH2F30TB21 cost to run per year?
At its rated efficiency it costs about $880-$2,254 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,071 in Phoenix and $1,873 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH2F30TB21?
ENERGY STAR lists 188 certified combinations for this outdoor unit. The highest-rated ones use XAFC48FXXN1+TXV, XAFB36DXXN1+TXV, XAFC48FBAN1.
What refrigerant does the York YH2F30TB21 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,055/yrYou save $469/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH2F30TB21
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,055
Current system, per year
$1,524
You save per year
$469
Payback
24.5 years
Net after 10 years
-$6,815

Cooling $660Heating $395Electricity used: 6,597 kWhSaved vs. a minimum-efficiency heat pump: $110

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 7, 2026. How we use the data.