HVAC Rated

2.5-ton central heat pump · 16 Single-Stage Heat Pump with WeatherGuard Top

Trane 5TWX6030A1

Below average cooling and heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #148 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $878 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
13,800 BTU/h52% of its 47°F output
Very good · beats 85%

A good fit if…

  • You want a choice of indoor units - 139 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2.5 ton, R-454B
General
BrandTrane
Outdoor unit model5TWX6030A1
Series16 Single-Stage Heat Pump with WeatherGuard Top
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 16, 2026
Last certifiedJune 12, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity27,200-29,600 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F24,800-26,800 BTU/h
Capacity at 17°F16,800-17,700 BTU/h
Capacity at 5°F13,100-13,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.12-2.28
ENERGY STAR cold climateNo
Heating output as it gets colder52% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5PX*C007AS3+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups139 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 139 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5PX*C007AS3+TSTATS9V2C100U5VSB16.012.08.113,300218110107
5PX*C007AS3+TSTATS9V2C080U5VSB16.012.08.113,400218110105
5TXCC007AS3+TSTATS9V2C080U5VSB16.012.08.113,400218110229
5TAMXD05AV41+TSTAT-16.012.08.113,400218110134
5TEMCD05AV41+TDR+TSTAT-16.012.08.113,200218110147
5TEMCD04AV31+TDR+TSTAT-16.012.08.113,200218110146
5TXCD010AS3+TSTATS9X2D120U5PSB16.012.08.113,300218112500
5TXCD010AS3+TSTATS9X1D120U5PSB16.012.08.113,300218112499
5TXCC009AS3+TSTATS9X2C100U5PSB16.012.08.113,300218112493
5TXCC009AS3+TSTATS9X1C100U5PSB16.012.08.113,300218112491
5TXCC009AS3+TSTATS9V2C100U5VSB16.012.08.113,200218112489
5TXCC009AS3+TSTATS9V2C100U4VSB16.012.08.113,200218112488
5TXCC009AS3+TSTATS9V2C080U5VSB16.012.08.113,400218112487
5TEMCD06AV41+TDR+TSTAT-16.012.08.113,200218112456
5PX*D010AS3+TSTATS9X1D120U5PSB16.012.08.113,300218112451
5PX*D010AS3+TSTATS9X2D120U5PSB16.012.08.113,300218112449
5PX*C009AS3+TSTATS9V2C080U5VSB16.012.08.113,400218112432
5PX*C009AS3+TSTATS9V2C100U4VSB16.012.08.113,200218112431
5PX*C009AS3+TSTATS9X2C100U5PSB16.012.08.113,300218112425
5PX*C009AS3+TSTATS9X1C100U5PSB16.012.08.113,300218112423
5PX*C009AS3+TSTATS9V2C100U5VSB16.012.08.113,200218112421
5TEMCD07AV51+TDR+TSTAT-16.012.08.113,100218159455
5TXCC007AS3+TSTATS9V2C100U5VSB16.012.08.113,500218396101
5PX*D008AS3+TSTAT*UHMD120CCV516.012.08.013,100218110128
5PX*C007AS3+TSTATS9V2C100U4VSB16.012.08.013,200218110106
5PX*C007AS3+TSTAT*UHMC100CCV416.012.08.013,100218110104
5PX*BD06AS3+TSTAT+P0V0B000M40SD-16.012.08.013,300218110089
5PX*B006AS3+TSTAT+P0V0B000M40SD-16.012.08.013,100218110041
5TXCD008AS3+TSTAT*UHMD120CCV516.012.08.013,100218110234
5TAMXD06AV41+TSTAT-16.012.08.013,300218110135
5PX*C007AS3+TSTATS9X2C080U5PSB16.012.08.013,400218159332
5PX*C007AS3+TSTATS9X1C080U5PSB16.012.08.013,400218159331
5PX*B006AS3+TSTAT*UHMB080CCV316.012.08.013,100218396009
5TXCD008AS3+TSTATS9X2D120U5PSB15.512.08.113,300218112497
5TXCD008AS3+TSTATS9X1D120U5PSB15.512.08.113,300218112496
5TXCC009AS3+TSTATS8X2C080M5PTC15.512.08.113,400218112486
5TXCC009AS3+TSTATS8X2C080M5PSC15.512.08.113,400218112485
5TXCC009AS3+TSTATS8X1C080M5PTC15.512.08.113,400218112484
5TXCC009AS3+TSTATS8X1C080M5PSC15.512.08.113,400218112483
5TXCC009AS3+TSTATS8V2C100M5PDB15.512.08.113,400218112482
5TXCC009AS3+TSTATS8V2C100M5PCB15.512.08.113,400218112481
5PX*D010AS3+TSTAT*UHMD120CCV515.512.08.113,100218112450
5PX*D008AS3+TSTATS9X2D120U5PSB15.512.08.113,300218112447
5PX*D008AS3+TSTATS9X1D120U5PSB15.512.08.113,300218112446
5PX*C009AS3+TSTATS8X2C080M5PTC15.512.08.113,400218112433
5PX*C009AS3+TSTATS8V2C100M5PCB15.512.08.113,400218112430
5PX*C009AS3+TSTATS8V2C100M5PDB15.512.08.113,400218112429
5PX*C009AS3+TSTATS8X1C080M5PSC15.512.08.113,400218112428
5PX*C009AS3+TSTATS8X1C080M5PTC15.512.08.113,400218112427
5PX*C009AS3+TSTATS8X2C080M5PSC15.512.08.113,400218112422
5PX*C007AS3+TSTATS9X1C100U5PSB15.512.08.113,400218112417
5PX*C007AS3+TSTATS9X2C100U5PSB15.512.08.113,400218112416
5PX*DD10AS3+TSTAT*DHMD120CCV515.512.08.013,200218112453
5TXCC007AS3+TSTATS9X1C080U5PSB15.212.08.113,400218110222
5TXCC007AS3+TSTATS9V2C100U4VSB15.212.08.113,200218110230
5TXCC007AS3+TSTAT*UHMC100CCV415.212.08.113,300218110226
5TXCC007AS3+TSTATS9X2C080U5PSB15.212.08.113,400218110224
5TEM4D04AC31+TDR+TSTAT-15.212.08.113,300218110137
5TEM4B03AC31+TDR+TSTAT-15.212.08.113,400218110136
5TEM6D05AV41+TDR+TSTAT-15.212.08.113,300218110141
Yearly running cost in 10 large cities$837-$2,057

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 5TWX6030A1?
The Trane 5TWX6030A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 139 certified matchups SEER2 ranges from 15.2-16.0.
Is the Trane 5TWX6030A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Trane 5TWX6030A1 cost to run per year?
At its rated efficiency it costs about $837-$2,057 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,007 in Phoenix and $1,699 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 5TWX6030A1?
ENERGY STAR lists 139 certified combinations for this outdoor unit. The highest-rated ones use 5PX*C007AS3+TSTAT, 5TXCC007AS3+TSTAT, 5TAMXD05AV41+TSTAT.
What refrigerant does the Trane 5TWX6030A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $986/yrYou save $443/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWX6030A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$986
Current system, per year
$1,429
You save per year
$443
Payback
23.7 years
Net after 10 years
-$6,071

Cooling $629Heating $357Electricity used: 6,162 kWhSaved vs. a minimum-efficiency heat pump: $103

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 12, 2026. How we use the data.