HVAC Rated

2.5-ton central heat pump · 15 Single-Stage Heat Pump

Trane 5TWR5030A1

Below average cooling and heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #145 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $869 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
13,800 BTU/h53% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 140 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2.5 ton, R-454B
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model5TWR5030A1
Series15 Single-Stage Heat Pump
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 25, 2024
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity26,400-29,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F24,200-26,400 BTU/h
Capacity at 17°F16,300-17,700 BTU/h
Capacity at 5°F12,700-13,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder53% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCB006AS3+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups140 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 140 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCB006AS3+TSTATS8X1A040M3PSC16.012.08.112,900214078391
5TXCB006AS3+TSTATS8X1A040M3PTC16.012.08.112,900214078393
5TXCB006AS3+TSTATS8X2A040M3PSC16.012.08.112,900214078403
5TXCB006AS3+TSTATS8X2A040M3PTC16.012.08.112,900214078405
5PX*B006AS3+TSTATS8X2A040M3PSC16.012.08.112,700215567760
5PX*B006AS3+TSTATS9X2B040U3PSB16.011.78.113,800215567718
5PX*B006AS3+TSTAT+P0V0B000M40SD-16.012.08.113,500215567734
5PX*B006AS3+TSTATS8X1A040M3PSC16.012.08.112,700215567748
5PX*B006AS3+TSTATS8X1A040M3PTC16.012.08.112,700215567750
5PX*B006AS3+TSTATS8X2A040M3PTC16.012.08.112,700215567762
5PX*BD06AS3+TSTAT+P0V0B000M40SD-16.012.08.113,700215567868
5PX*CD07AS3+TSTATS9V2C100D5PSC16.012.08.113,600215568008
5PX*CD07AS3+TSTATS9V2C100D4VSB16.012.08.113,600215568010
5PX*C007AS3+TSTATS9V2C100U5PSC16.012.08.113,500215567950
5PX*C007AS3+TSTATS9V2C100U4VSB16.012.08.113,500215567952
5PX*C007AS3+TSTATS9V2C080U5PSC16.012.08.113,600215567954
5PX*D008AS3+TSTAT*UHMD120CCV516.012.08.113,400215568042
5TXCD008AS3+TSTAT*UHMD120CCV516.012.08.113,400215566270
5PX*B006AS3+TSTATS9X1B040U3PSB16.011.78.113,800215567712
5TEM6D05AV41+TDR+TSTAT-16.012.08.113,800215610931
5TEMCD04AV31+TDR+TSTAT-16.012.08.113,300215863928
5TEMCD05AV41+TDR+TSTAT-16.012.08.113,300215863930
5PX*C007AS3+TSTATS9V2C080U5VSB16.012.08.113,500215831424
5PX*C007AS3+TSTATS9V2C100U5VSB16.012.08.113,400215831426
5PX*CD07AS3+TSTATS9V2C100D5VSB16.012.08.113,500215831430
5TXCC007AS3+TSTATS9V2C100U5VSB16.012.08.113,500215831446
5TXCC007AS3+TSTATS9V2C080U5VSB16.012.08.113,500215831448
5TAMXD05AV41+TSTAT-16.012.08.113,300216056964
5PX*B006AS3+TSTATS9X2B080U4PSB16.012.08.013,700215567722
5PX*B006AS3+TSTAT*UHMB080CCV316.012.08.013,400215567780
5PX*C007AS3+TSTATS9X2C080U5PSB16.012.08.013,300215567946
5PX*C007AS3+TSTATS9X1C080U5PSB16.012.08.013,300215567948
5PX*C007AS3+TSTATS8V2C100M5PDB16.012.08.013,600215567964
5PX*C007AS3+TSTATS8V2C080M5PDB16.012.08.013,500215567966
5PX*C007AS3+TSTATS8V2C100M5PCB16.012.08.013,600215567968
5PX*C007AS3+TSTATS8V2C080M5PCB16.012.08.013,500215567970
5PX*C007AS3+TSTAT*UHMC100CCV416.012.08.013,300215567972
5PX*B006AS3+TSTATS9X1B080U4PSB16.012.08.013,700215567716
5TAMXD06AV41+TSTAT-16.012.08.013,400216056966
5TEM6D04AV31+TDR+TSTAT-15.212.08.113,500214078349
5TEM6D06AV41+TDR+TSTAT-15.212.08.113,400214078351
5TEM6D07AV51+TDR+TSTAT-15.212.08.113,400214078353
5TXCB004AS3+TSTATS9V2B040U3PSB15.211.78.113,500214078359
5TXCB004AS3+TSTATS9V2B040U3VSA15.211.78.113,500214078361
5TXCC007AS3+TSTATS8X1C080M5PSC15.212.08.113,500214078501
5TXCC007AS3+TSTATS8X1C080M5PTC15.212.08.113,500214078503
5TXCC007AS3+TSTATS8X2C080M5PSC15.212.08.113,500214078505
5TXCC007AS3+TSTATS8X2C080M5PTC15.212.08.113,500214078507
5TXCC007AS3+TSTATS9V2C080U5PSB15.212.08.113,500214078509
5TXCC007AS3+TSTATS9V2C080U5PSC15.212.08.113,500214078511
5TXCC007AS3+TSTATS9V2C100U4VSA15.212.08.113,200214078513
5TXCC007AS3+TSTATS9V2C100U4VSB15.212.08.113,500214078515
5TXCD010AS3+TSTAT*UHMD120ACV515.212.08.113,000214078519
5TXCB006AS3+TSTATS9V2B060U4PSB15.211.78.113,700214078423
5TXCB006AS3+TSTATS9V2B060U4PSC15.212.08.113,700214078425
5TXCB006AS3+TSTATS9V2B080U4PSB15.212.08.113,200214078433
5TXCB006AS3+TSTATS9V2B080U4PSC15.212.08.113,600214078435
5TXCB006AS3+TSTATS9V2B080U4VSA15.211.78.113,800214078437
5TXCB006AS3+TSTATS9X1B040U3PSB15.211.78.113,500214078439
5TXCB006AS3+TSTATS9X1B060U4PSB15.211.78.113,600214078441
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 5TWR5030A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$826-$2,038

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 5TWR5030A1?
The Trane 5TWR5030A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 140 certified matchups SEER2 ranges from 15.2-16.0.
Is the Trane 5TWR5030A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Trane 5TWR5030A1 cost to run per year?
At its rated efficiency it costs about $826-$2,038 a year in electricity in large U.S. cities, depending on climate and local rates - for example $994 in Phoenix and $1,685 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 5TWR5030A1 the same as the American Standard 5A6H5030A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 5TWR5030A1?
ENERGY STAR lists 140 certified combinations for this outdoor unit. The highest-rated ones use 5TXCB006AS3+TSTAT, 5PX*B006AS3+TSTAT, 5PX*B006AS3+TSTAT+P0V0B000M40SD.
What refrigerant does the Trane 5TWR5030A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $974/yrYou save $437/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWR5030A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$974
Current system, per year
$1,412
You save per year
$437
Payback
24.0 years
Net after 10 years
-$6,129

Cooling $620Heating $354Electricity used: 6,090 kWhSaved vs. a minimum-efficiency heat pump: $102

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.