HVAC Rated

2.5-ton central heat pump · F-SERIES PLUS

Friedrich FWP15AZ30AJ2N

Below average cooling and heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #136 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $929 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
16,100 BTU/h55% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 90 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandFriedrich
Outdoor unit modelFWP15AZ30AJ2N
SeriesF-SERIES PLUS
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 27, 2023
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity28,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F28,400 BTU/h
Capacity at 17°F18,300-20,200 BTU/h
Capacity at 5°F14,100-16,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder55% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FRH2VZ3617STANN at the standard test temperatures, in BTU/h:

Certified matchups90 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 90 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FRH2VZ3617STANN-16.011.78.115,600213382080
FRH2VZ3621MTANA-16.011.78.114,300213382076
FRH2VZ3621MTANN-16.011.77.814,200213382081
FRH3VZ3617STACN-16.011.77.814,100214664601
TCFZ3617STANMFR98MV0603A17UP15.211.78.115,800213841257
TCFZ3617STANMFR962V0603A17M415.211.78.116,100213841260
TCFZ3617STANMFR98MV0703A17UP15.211.78.115,800213841255
TCFZ3617STANMFR951V0603A17M415.211.78.116,100213841293
TCFZ3617STANMFR921V0703A17M415.211.78.116,000213841291
TCFZ3617STANMFR951V0403A17M415.211.78.116,000213841298
TCFZ3617STANMFR921V0403A17M415.211.78.116,000213841297
TCFZ3617STANMFR962V0403A17M415.211.78.116,000213841285
TCFZ3617STANMFR962V0703A17M415.211.78.116,000213841280
TCFZ3617STANMFR921V0603A17M415.211.78.116,100213841324
TCFZ3617STANMFR951V0703A17M415.211.78.116,000213841300
TCFZ3617STANMFR801V1004A17UH15.211.78.115,900213841333
TCFZ3617STANMFR801V0754A17UH15.211.78.115,900213841329
TCFZ3617STANMFR801V0503A14UH15.211.78.116,000213841344
TCFZ3617STANMFR802V1004A17UH15.211.78.116,000213841337
TCFZ3617STANMFR802V0504A17UH15.211.78.116,100213841353
TCFZ3617STANMFR801V0754A17DZ15.211.78.116,000213841351
TCFZ3617STANMFR802V0754A17UH15.211.78.115,900213841358
TCFZ3617STANMFR801V0504A17UHN15.211.78.116,100213841362
TCFZ3617STANMFR802V0754A17DZ15.211.78.116,000213841364
TCFZ3617STANMFR801V0503A14DZ15.211.78.116,100213841372
TCFZ3617STANMFR801V0504A17UHU15.211.78.116,100213841376
TCFZ3617STANMFR802V0503A14DZ15.211.78.116,100213841382
TCFZ3617STANMFR801V0504A17UHS15.211.78.116,100213841388
TCFZ3617STANMFR801V0704A17UHU15.211.78.116,000213841387
TCFZ3617STANMFR802V0503A14UH15.211.78.116,000213841383
RCFZ3617STANMFR962V0603A17M415.211.78.116,100214327966
RCFZ3617STANMFR962V0703A17M415.211.78.116,000214327977
RCFZ3617STANMFR951V0603A17M415.211.78.116,100214327983
RCFZ3617STANMFR962V0403A17M415.211.78.116,000214327980
RCFZ3617STANMFR921V0703A17M415.211.78.116,000214327982
RCFZ3617STANMFR98MV0603A17UP15.211.78.115,800214327965
RCFZ3617STANMFR98MV0703A17UP15.211.78.115,800214327963
RCFZ3617STANMFR801V0503A14UH15.211.78.116,000214328006
RCFZ3617STANMFR801V1004A17UH15.211.78.115,900214328001
RCFZ3617STANMFR921V0403A17M415.211.78.116,000214327984
RCFZ3617STANMFR801V0754A17UH15.211.78.115,900214328000
RCFZ3617STANMFR802V1004A17UH15.211.78.116,000214328002
RCFZ3617STANMFR951V0703A17M415.211.78.116,000214327986
RCFZ3617STANMFR951V0403A17M415.211.78.116,000214327985
RCFZ3617STANMFR921V0603A17M415.211.78.116,100214327997
RCFZ3617STANMFR801V0504A17UHU15.211.78.116,100214328022
RCFZ3617STANMFR802V0503A14UH15.211.78.116,000214328026
RCFZ3617STANMFR801V0754A17DZ15.211.78.116,000214328011
RCFZ3617STANMFR802V0754A17UH15.211.78.115,900214328015
RCFZ3617STANMFR802V0504A17UH15.211.78.116,100214328012
RCFZ3617STANMFR801V0504A17UHN15.211.78.116,100214328016
RCFZ3617STANMFR802V0754A17DZ15.211.78.116,000214328017
RCFZ3617STANMFR801V0503A14DZ15.211.78.116,100214328020
RCFZ3617STANMFR801V0704A17UHU15.211.78.116,000214328029
RCFZ3617STANMFR802V0503A14DZ15.211.78.116,100214328025
RCFZ3617STANMFR801V0504A17UHS15.211.78.116,100214328030
FRH2TZ3617STANN-15.211.77.815,600213087950
FRH2VZ3621STANN-15.211.77.814,200213382074
TCFZ3621STANMFR98MV0603A17UP15.211.77.814,400213841252
TCFZ3621STANMFR98MV0703A17UP15.211.77.814,400213841267
Yearly running cost in 10 large cities$834-$2,218

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FWP15AZ30AJ2N?
The Friedrich FWP15AZ30AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 90 certified matchups SEER2 ranges from 15.2-16.0.
Is the Friedrich FWP15AZ30AJ2N good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Friedrich FWP15AZ30AJ2N cost to run per year?
At its rated efficiency it costs about $834-$2,218 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,026 in Phoenix and $1,852 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FWP15AZ30AJ2N?
ENERGY STAR lists 90 certified combinations for this outdoor unit. The highest-rated ones use FRH2VZ3617STANN, FRH2VZ3621MTANA, FRH2VZ3621MTANN.
What refrigerant does the Friedrich FWP15AZ30AJ2N use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,017/yrYou save $447/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FWP15AZ30AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,017
Current system, per year
$1,464
You save per year
$447
Payback
23.5 years
Net after 10 years
-$6,031

Cooling $625Heating $393Electricity used: 6,359 kWhSaved vs. a minimum-efficiency heat pump: $106

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.