12,000 BTU mini-split heat pump · IDU Series

Kepler ODUMOX330-12HFN1MW5W

Very good cooling efficiency and average heating efficiency for a 12,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #61 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $278 a year to run in a mixed climate like Atlanta.

SEER2
25.5 Cooling efficiency over a season
Very good · beats 88%
HSPF2
10.7 Heating efficiency over a season
Average · beats 68%
EER2
14.0 Cooling efficiency on a 95°F day
Very good · beats 82%
Heat at 5°F
12,100 BTU/h100% of its 47°F output
Below average · beats 38%

A good fit if…

  • You want low cooling bills - its SEER2 beats 88% of mini-splits.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 12,100 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications12,000 BTU, R-410A
General
BrandKepler
Outdoor unit modelODUMOX330-12HFN1MW5W
SeriesIDU Series
TypeMini-split heat pump
Nominal size12,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMay 20, 2024
Last certifiedJune 13, 2026
Cooling
SEER2Seasonal efficiency, higher is better25.5 (range 19.5-25.5)
EER2Efficiency at 95°F outdoors11.7-14.0
Cooling capacity12,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0-10.7
Capacity at 47°F12,000-12,500 BTU/h
Capacity at 17°F9,900-10,600 BTU/h
Capacity at 5°F11,300-12,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.99
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with IDUMSEPB-12HRFN1MW5W(GA) at the standard test temperatures, in BTU/h:

Certified matchups4 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
IDUMSEPB-12HRFN1MW5W(GA) · cold climate25.514.010.412,000213608174
IDUMFA2U-12HRFN1-MW5W · cold climate24.213.310.711,900214377775
IDUCCA3U-12HRFN1-M(C) · cold climate22.312.710.211,300214377772
IDUMTIU-12HWFN1-M · cold climate19.511.710.012,100214377768
Yearly running cost in 10 large cities$223-$686

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Kepler ODUMOX330-12HFN1MW5W?
The Kepler ODUMOX330-12HFN1MW5W is rated at up to 25.5 SEER2 and 14.0 EER2 for cooling and up to 10.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 19.5-25.5.
Is the Kepler ODUMOX330-12HFN1MW5W good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 12,100 BTU/h at 5°F with a COP of 1.99, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Kepler ODUMOX330-12HFN1MW5W cost to run per year?
At its rated efficiency it costs about $223-$686 a year in electricity in large U.S. cities, depending on climate and local rates - for example $287 in Phoenix and $583 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Kepler ODUMOX330-12HFN1MW5W?
ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use IDUMSEPB-12HRFN1MW5W(GA), IDUMFA2U-12HRFN1-MW5W, IDUCCA3U-12HRFN1-M(C).
What refrigerant does the Kepler ODUMOX330-12HFN1MW5W use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $291/yrYou save $327/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Kepler ODUMOX330-12HFN1MW5W
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$291
Current system, per year
$619
You save per year
$327
Payback
13.7 years
Net after 10 years
-$1,225

Cooling $166Heating $126Electricity used: 1,820 kWhSaved vs. a minimum-efficiency heat pump: $183

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 12,000 BTU models

See all 394 12,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 13, 2026. How we use the data.