12,000 BTU mini-split heat pump · MCBU series
MDV MOX330-12HFN1-MW5W
Very good cooling efficiency and average heating efficiency for a 12,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #63 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $278 a year to run in a mixed climate like Atlanta.
- SEER2
- 25.5 Cooling efficiency over a seasonVery good · beats 88%
- HSPF2
- 10.7 Heating efficiency over a seasonAverage · beats 68%
- EER2
- 14.0 Cooling efficiency on a 95°F dayVery good · beats 82%
- Heat at 5°F
- 12,100 BTU/h100% of its 47°F outputBelow average · beats 38%
A good fit if…
- You want low cooling bills - its SEER2 beats 88% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 12,100 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 20 certified pairings.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Also sold as | ECO-AIR, Alsetria, Midea |
| Outdoor unit model | MOX330-12HFN1-MW5W |
| Series | MCBU series |
| Type | Mini-split heat pump |
| Nominal size | 12,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | August 20, 2020 |
| Last certified | June 25, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 25.5 (range 19.5-25.5) |
| EER2Efficiency at 95°F outdoors | 11.7-14.0 |
| Cooling capacity | 12,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.5-10.7 |
| Capacity at 47°F | 12,000-12,500 BTU/h |
| Capacity at 17°F | 7,500-10,600 BTU/h |
| Capacity at 5°F | 10,000-12,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.99 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MSEPB-12HRFN1-MW5W(GA) at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MSEPB-12HRFN1-MW5W(GA) · cold climate | 25.5 | 14.0 | 10.4 | 12,000 | 205993846 |
| MSEPB-12HRFN1-MW5W(GA) ECO-AIR · cold climate | 25.5 | 14.0 | 10.4 | 12,000 | 208121865 |
| MSEPB-12HRFN1-MW5W(GA) Alsetria · cold climate | 25.5 | 14.0 | 10.4 | 12,000 | 208121902 |
| MSEPB-12HRFN1-MW5W(GA) MIDEA · cold climate | 25.5 | 14.0 | 10.4 | 12,000 | 207826694 |
| MFA2U-12HRFN1-MW5W · cold climate | 24.2 | 13.3 | 10.7 | 11,900 | 209248924 |
| MFA2U-12HRFN1-MW5W ECO-AIR · cold climate | 24.2 | 13.3 | 10.7 | 11,900 | 214655290 |
| MFAU-12HRFN1-M(C) · cold climate | 23.6 | 13.0 | 10.0 | 12,000 | 206330128 |
| CS11M-12HRFN1-MU5W · cold climate | 23.6 | 13.5 | 9.5 | 10,000 | 205993853 |
| MSAG11B-12HRFN1-MV0W(GA) · cold climate | 23.1 | 13.0 | 10.5 | 11,000 | 206361861 |
| MCBU-18HRFN1-MW-CA · cold climate | 23.0 | 13.0 | 10.0 | 11,000 | 210857290 |
| MCBU-12HRFN1-MV0W · cold climate | 23.0 | 13.0 | 10.0 | 11,000 | 209270211 |
| MCBU-12HRFN1-MV0W ECO-AIR · cold climate | 23.0 | 13.0 | 10.0 | 11,000 | 211644094 |
| MCBU-12HRFN1-MV0W Alsetria · cold climate | 23.0 | 13.0 | 10.0 | 11,000 | 211644100 |
| MCA3U-12HRFN1-M(C) · cold climate | 22.3 | 12.7 | 10.2 | 11,300 | 206330126 |
| CCA3U-12HRFN1-M(C) Alsetria · cold climate | 22.3 | 12.7 | 10.2 | 11,300 | 211644044 |
| CCA3U-12HRFN1-M(C) ECO-AIR · cold climate | 22.3 | 12.7 | 10.2 | 11,300 | 211644069 |
| MTI-12HWFN1-MST0 · cold climate | 20.0 | 12.0 | 9.5 | 12,000 | 210299304 |
| MTIU-12HWFN1-M · cold climate | 19.5 | 11.7 | 10.0 | 12,100 | 206330127 |
| MTIU-12HWFN1-M Alsetria · cold climate | 19.5 | 11.7 | 10.0 | 12,100 | 211644038 |
| MTIU-12HWFN1-M ECO-AIR · cold climate | 19.5 | 11.7 | 10.0 | 12,100 | 211644063 |
Yearly running cost in 10 large cities
- Phoenix, AZ$287/yr
- Miami, FL$223/yr
- Houston, TX$258/yr
- Atlanta, GA$278/yr
- Los Angeles, CA$275/yr
- New York, NY$686/yr
- Chicago, IL$561/yr
- Denver, CO$470/yr
- Seattle, WA$291/yr
- Minneapolis, MN$583/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOX330-12HFN1-MW5W?
- The MDV MOX330-12HFN1-MW5W is rated at up to 25.5 SEER2 and 14.0 EER2 for cooling and up to 10.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 20 certified matchups SEER2 ranges from 19.5-25.5.
- Is the MDV MOX330-12HFN1-MW5W good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 12,100 BTU/h at 5°F with a COP of 1.99, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOX330-12HFN1-MW5W cost to run per year?
- At its rated efficiency it costs about $223-$686 a year in electricity in large U.S. cities, depending on climate and local rates - for example $287 in Phoenix and $583 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOX330-12HFN1-MW5W?
- ENERGY STAR lists 20 certified combinations for this outdoor unit. The highest-rated ones use MSEPB-12HRFN1-MW5W(GA), ECO-AIR MSEPB-12HRFN1-MW5W(GA), Alsetria MSEPB-12HRFN1-MW5W(GA).
- What refrigerant does the MDV MOX330-12HFN1-MW5W use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 12,000 BTU models
- KERR A-KMH12SV-1 · cold climate25.5 SEER2 · 10.7 HSPF2
- MOOVAIR DMA12HOS28230E8 · cold climate25.5 SEER2 · 10.7 HSPF2
- Kepler ODUMOX330-12HFN1MW5W · cold climate25.5 SEER2 · 10.7 HSPF2
- Senville SENA/12HF/OQ · cold climate25.5 SEER2 · 10.7 HSPF2
- Elios DEA12HOS28230E8 · cold climate25.5 SEER2 · 10.7 HSPF2
- WeatherMaker 38MARBQ12AA3 · cold climate25.5 SEER2 · 10.7 HSPF2
- DIYCOOL ACIQ-12ZPL-HP230B · cold climate25.5 SEER2 · 10.7 HSPF2
- Bosch BMS500-AAS012-1CSXRD · cold climate25.5 SEER2 · 10.6 HSPF2
See all 394 12,000 BTU mini-splits, ranked