HVAC Rated

60,000 BTU mini-split heat pump · KUMXB601A

LG KUMXB601A

Below average cooling efficiency and average heating efficiency for a 60,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #21 of 44 60,000 BTU mini-splits for cooling efficiency, and costs about $1,615 a year to run in a mixed climate like Atlanta.

SEER2
20.5 Cooling efficiency over a season
Below average · beats 24%
HSPF2
10.0 Heating efficiency over a season
Average · beats 43%
EER2
12.0 Cooling efficiency on a 95°F day
Below average · beats 25%
Heat at 5°F
46,000 BTU/h72% of its 47°F output
Average · beats 58%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for mini-splits.

Calculate my running cost

Details

Specifications60,000 BTU, R-32
General
BrandLG
Outdoor unit modelKUMXB601A
SeriesKUMXB601A
TypeMini-split heat pump
Nominal size60,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceOctober 22, 2024
Last certifiedNovember 7, 2025
Cooling
SEER2Seasonal efficiency, higher is better20.5 (range 18.5-20.5)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity56,000-60,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5-10.0
Capacity at 47°F64,000 BTU/h
Capacity at 17°F40,000-42,000 BTU/h
Capacity at 5°F45,000-46,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.97-2.01
ENERGY STAR cold climateNo
Heating output as it gets colder72% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
-20.512.010.046,000215402343
-19.511.99.845,500215408633
-18.511.79.545,000215402344
Yearly running cost in 10 large cities$1,335-$3,949

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the LG KUMXB601A?
The LG KUMXB601A is rated at up to 20.5 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 18.5-20.5.
Is the LG KUMXB601A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 60,000 BTU model.
How much does the LG KUMXB601A cost to run per year?
At its rated efficiency it costs about $1,335-$3,949 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,699 in Phoenix and $3,340 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the LG KUMXB601A use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,713/yrYou save $1,376/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump LG KUMXB601A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,713
Current system, per year
$3,089
You save per year
$1,376
Payback
16.0 years
Net after 10 years
-$8,239

Cooling $996Heating $717Electricity used: 10,704 kWhSaved vs. a minimum-efficiency heat pump: $671

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 60,000 BTU models

See all 44 60,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of November 7, 2025. How we use the data.