60,000 BTU mini-split heat pump · M-Series
TOSOT TGWHD-60ND
Below average cooling efficiency and average heating efficiency for a 60,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #18 of 44 60,000 BTU mini-splits for cooling efficiency, and costs about $1,425 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.0 Cooling efficiency over a seasonBelow average · beats 30%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 11.7 Cooling efficiency on a 95°F dayBelow average · beats 14%
- Heat at 5°F
- 36,400 BTU/h66% of its 47°F outputVery good · beats 86%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | TOSOT |
| Also sold as | Blueridge, GREE, Kinghome, AIR MAX |
| Outdoor unit model | TGWHD-60ND |
| Series | M-Series |
| Type | Mini-split heat pump |
| Nominal size | 60,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | November 6, 2025 |
| Last certified | July 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.0 (range 19.0-21.0) |
| EER2Efficiency at 95°F outdoors | 11.7-11.8 |
| Cooling capacity | 55,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.0-10.0 |
| Capacity at 47°F | 55,000 BTU/h |
| Capacity at 17°F | 40,000-41,000 BTU/h |
| Capacity at 5°F | 31,000-36,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.30 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - | 21.0 | 11.7 | 10.0 | 36,400 | 218389043 |
| - | 20.0 | 11.8 | 9.0 | 32,000 | 218389045 |
| - | 19.0 | 11.7 | 8.0 | 31,000 | 218389044 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the TOSOT TGWHD-60ND: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
Yearly running cost in 10 large cities
- Phoenix, AZ$1,540/yr
- Miami, FL$1,233/yr
- Houston, TX$1,381/yr
- Atlanta, GA$1,425/yr
- Los Angeles, CA$1,393/yr
- New York, NY$3,439/yr
- Chicago, IL$2,799/yr
- Denver, CO$2,332/yr
- Seattle, WA$1,437/yr
- Minneapolis, MN$2,888/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the TOSOT TGWHD-60ND?
- The TOSOT TGWHD-60ND is rated at up to 21.0 SEER2 and 11.7 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 19.0-21.0.
- Is the TOSOT TGWHD-60ND good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 60,000 BTU model.
- How much does the TOSOT TGWHD-60ND cost to run per year?
- At its rated efficiency it costs about $1,233-$3,439 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,540 in Phoenix and $2,888 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the TOSOT TGWHD-60ND the same as the TOSOT TM60WH21MO?
- Yes, as far as the certified ratings go. ENERGY STAR lists 9 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- What refrigerant does the TOSOT TGWHD-60ND use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 60,000 BTU models
- GREE MUL60HP230V1R32AO21.0 SEER2 · 10.0 HSPF2
- GE Appliances MWHQ060NC2AA · cold climate21.0 SEER2 · 11.0 HSPF2
- GREE GMV-V60WL/C-T(U) · cold climate21.0 SEER2 · 9.2 HSPF2
- Hitachi HVAHP060C23S21.8 SEER2 · 9.8 HSPF2
- LG KUMXB601A20.5 SEER2 · 10.0 HSPF2
- MDV M5OA-55HFN1-M-[X](2) · cold climate22.0 SEER2 · 9.5 HSPF2
- Mitsubishi Electric MXZ-SM60NLHZ · cold climate20.0 SEER2 · 10.9 HSPF2
- DIYCOOL ACIQ-55Z-HH-M5B · cold climate22.0 SEER2 · 9.5 HSPF2
See all 44 60,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.