3-ton central heat pump · LX SERIES
Luxaire THF2B36T21
Below average cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #234 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,131 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 20,000 BTU/h54% of its 47°F outputExcellent · beats 97%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 20,000 BTU/h at 5°F.
- You want a choice of indoor units - 1,095 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Luxaire |
| Also sold as | Coleman, Fraser-Johnston, Johnson Controls, CHAMPION HEATING AND COOLING |
| Outdoor unit model | THF2B36T21 |
| Series | LX SERIES |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | May 18, 2023 |
| Last certified | July 15, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 33,400-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 32,600-34,800 BTU/h |
| Capacity at 17°F | 21,400-23,800 BTU/h |
| Capacity at 5°F | 16,500-20,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.96-2.44 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAHC36DBCN1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,095 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| XAHC36DBCN1 | Z8ES080C20SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485545 |
| XAHC36DBCN1 | Z8ES120C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478022 |
| XAHC36DBCN1 | Z8ES080C20SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485544 |
| XAHC36DBCN1 | Z8ES080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475474 |
| XAHC36DBCN1 | Z8ES080C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485551 |
| XAHC36DBCN1 | Z8ES120C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478018 |
| XAHC36DBCN1 | Z8ES120C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478017 |
| XAHC36DBCN1 | Z8ES080C20SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485548 |
| XAHC36DBCN1 | Z8ES120C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478016 |
| XAHC36DBCN1 | Z8ES120C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478024 |
| XAHC36DBCN1 | Z8ES120C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478023 |
| XAHC36DBCN1 | Z8ES120C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478020 |
| XAHC36DBCN1 | Z8ES120C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478027 |
| XAHC36DBCN1 | Z8ES120C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478021 |
| XAHC36DBCN1 | Z8ES120C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,500 | 212478019 |
| XAHC36DBCN1 | Z8ES080C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485555 |
| XAHC36DBCN1 | Z8ES080C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475462 |
| XAHC36DBCN1 | Z8ES080C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475464 |
| XAHC36DBCN1 | Z8ES080C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475466 |
| XAHC36DBCN1 | Z8ES080C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475468 |
| XAHC36DBCN1 | Z8ES080C16SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475470 |
| XAHC36DBCN1 | Z8ES080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475472 |
| XAHC36DBCN1 | Z8ES080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475478 |
| XAHC36DBCN1 | Z8ES080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475476 |
| XAHC36DBCN1 | Z8ES080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212475484 |
| XAHC36DBCN1 | Z8ES080C20SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485546 |
| XAHC36DBCN1 | Z8ES080C20SMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485547 |
| XAHC36DBCN1 | Z8ES080C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485549 |
| XAHC36DBCN1 | Z8ES080C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485550 |
| XAHC36DBCN1 | Z8ES080C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212485552 |
| XAHD48FBCN1+JMVT20DC2N1 | - | 16.0 | 12.0 | 8.1 | 17,200 | 210343560 |
| XAHD48FBCN1+JMVT20DC2N1 | - | 16.0 | 12.0 | 8.1 | 17,200 | 210343561 |
| XAHD48FBCN1+JMVT20DC2N1 | - | 16.0 | 12.0 | 8.1 | 17,200 | 210343562 |
| XAHD48FBCN1+JMVT20DC2N1 | - | 16.0 | 12.0 | 8.1 | 17,200 | 210343563 |
| XAHC36DBCN1+JMVT17CC2N1 | - | 16.0 | 11.7 | 8.1 | 17,400 | 210358459 |
| XAHC36DBCN1+JMVT17CC2N1 | - | 16.0 | 11.7 | 8.1 | 17,400 | 210358458 |
| XAHC36DBCN1+JMVT17CC2N1 | - | 16.0 | 11.7 | 8.1 | 17,400 | 210358457 |
| XAHC36DBCN1+JMVT17CC2N1 | - | 16.0 | 11.7 | 8.1 | 17,400 | 210358456 |
| XAHC36DBCN1+JMVT17CC2N1 | - | 16.0 | 11.7 | 8.1 | 17,400 | 210846624 |
| XAHD48FBCN1+JMVT20DC2N1 | - | 16.0 | 12.0 | 8.1 | 17,200 | 210848072 |
| XAHC36DBCN1 | Z8ET080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,600 | 212593946 |
| XAHC36DBCN1 | Z8ET080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,600 | 212593947 |
| XAHC36DBCN1 | Z8ET080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,600 | 212593950 |
| XAHC36DBCN1 | Z8ET080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,600 | 212593949 |
| XAHC36DBCN1 | Z8ET080C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,600 | 212593948 |
| XAHD48FBCN1 | Z8ET080C16LMPS1 | 16.0 | 12.0 | 8.1 | 18,000 | 212594243 |
| XAHD48FBCN1 | Z8ET080C16LMPS1 | 16.0 | 12.0 | 8.1 | 18,000 | 212594242 |
| XAHD48FBCN1 | Z8ET080C16LMPS1 | 16.0 | 12.0 | 8.1 | 18,000 | 212594245 |
| XAHD48FBCN1 | Z8ET080C16LMPS1 | 16.0 | 12.0 | 8.1 | 18,000 | 212594246 |
| XAHD48FBCN1 | Z8ET080C16LMPS1 | 16.0 | 12.0 | 8.1 | 18,000 | 212594244 |
| XAHC36DBCN1 | Z8ET100C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,400 | 212594349 |
| XAHC36DBCN1 | Z8ET100C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,400 | 212594348 |
| XAHC36DBCN1 | Z8ET100C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,400 | 212594347 |
| XAHC36DBCN1 | Z8ET100C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,400 | 212594350 |
| XAHC36DBCN1 | Z8ET100C16LMPS1 | 16.0 | 11.7 | 8.1 | 18,400 | 212594351 |
| XAHC36DBCN1 | Z8ET100C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212594518 |
| XAHC36DBCN1 | Z8ET100C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212594519 |
| XAHC36DBCN1 | Z8ET100C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212594517 |
| XAHC36DBCN1 | Z8ET100C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212594521 |
| XAHC36DBCN1 | Z8ET100C20LMPS1 | 16.0 | 11.7 | 8.1 | 18,300 | 212594520 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,263/yr
- Miami, FL$1,033/yr
- Houston, TX$1,131/yr
- Atlanta, GA$1,131/yr
- Los Angeles, CA$1,097/yr
- New York, NY$2,686/yr
- Chicago, IL$2,177/yr
- Denver, CO$1,807/yr
- Seattle, WA$1,109/yr
- Minneapolis, MN$2,236/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Luxaire THF2B36T21?
- The Luxaire THF2B36T21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1095 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Luxaire THF2B36T21 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 20,000 BTU/h at 5°F with a COP of 2.44, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
- How much does the Luxaire THF2B36T21 cost to run per year?
- At its rated efficiency it costs about $1,033-$2,686 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,263 in Phoenix and $2,236 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Luxaire THF2B36T21?
- ENERGY STAR lists 1095 certified combinations for this outdoor unit. The highest-rated ones use XAHC36DBCN1, XAHD48FBCN1+JMVT20DC2N1, XAHC36DBCN1+JMVT17CC2N1.
- What refrigerant does the Luxaire THF2B36T21 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Coleman XH536E2S1116.0 SEER2 · 8.1 HSPF2
- Trane 5HPL5036A1000AA · cold climate16.0 SEER2 · 8.1 HSPF2
- RunTru A5HP5036A116.0 SEER2 · 8.5 HSPF2
- Trane N5HP5036A116.0 SEER2 · 8.1 HSPF2
- Willis FLEX24/36KUH · cold climate16.0 SEER2 · 9.0 HSPF2
- York YH2F36TB21 · cold climate16.0 SEER2 · 8.1 HSPF2
- MRCOOL CENTRAL-36-HP-C-230A00 · cold climate16.0 SEER2 · 9.5 HSPF2
- York YH536E2S1116.0 SEER2 · 8.1 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 15, 2026. How we use the data.