24,000 BTU mini-split heat pump · ML Series
Mainline ML24HP230NEXH-O
Average cooling efficiency and excellent heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #155 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $526 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.3 Cooling efficiency over a seasonAverage · beats 53%
- HSPF2
- 13.3 Heating efficiency over a seasonExcellent · beats 95%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 24,200 BTU/h92% of its 47°F outputVery good · beats 82%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,200 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 95% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 10 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Mainline |
| Outdoor unit model | ML24HP230NEXH-O |
| Series | ML Series |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | May 20, 2024 |
| Last certified | August 19, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.3 (range 18.7-22.3) |
| EER2Efficiency at 95°F outdoors | 12.0-12.5 |
| Cooling capacity | 22,000-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0-13.3 |
| Capacity at 47°F | 25,000-26,000 BTU/h |
| Capacity at 17°F | 16,900-23,000 BTU/h |
| Capacity at 5°F | 23,600-24,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.23 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ML24HP230NEX-I at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| ML24HP230NEX-I MAINLINE · cold climate | 22.3 | 12.5 | 13.3 | 24,000 | 217607255 |
| ML24HP230NEX-I MAINLINE · cold climate | 22.3 | 12.5 | 13.3 | 24,000 | 215864342 |
| ML24HP230STDCAS-I MAINLINE · cold climate | 20.7 | 12.0 | 11.6 | 23,800 | 217607285 |
| ML24HP230STDCAS-I MAINLINE · cold climate | 20.7 | 12.0 | 11.6 | 23,800 | 215864372 |
| ML24HP230FLO-I MAINLINE · cold climate | 20.4 | 12.0 | 12.1 | 24,200 | 217607298 |
| ML24HP230FLO-I MAINLINE · cold climate | 20.4 | 12.0 | 12.1 | 24,200 | 215864385 |
| ML24HP230HSDUC-I MAINLINE · cold climate | 19.0 | 12.0 | 11.7 | 24,000 | 217607293 |
| ML24HP230HSDUC-I MAINLINE · cold climate | 19.0 | 12.0 | 11.7 | 24,000 | 215864380 |
| ML24HP230AHU-I · cold climate | 18.7 | 12.0 | 10.0 | 23,600 | 217607162 |
| ML24HP230AHU-I · cold climate | 18.7 | 12.0 | 10.0 | 23,600 | 215864296 |
Yearly running cost in 10 large cities
- Phoenix, AZ$590/yr
- Miami, FL$484/yr
- Houston, TX$529/yr
- Atlanta, GA$526/yr
- Los Angeles, CA$510/yr
- New York, NY$1,247/yr
- Chicago, IL$1,010/yr
- Denver, CO$838/yr
- Seattle, WA$514/yr
- Minneapolis, MN$1,036/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Mainline ML24HP230NEXH-O?
- The Mainline ML24HP230NEXH-O is rated at up to 22.3 SEER2 and 12.5 EER2 for cooling and up to 13.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 10 certified matchups SEER2 ranges from 18.7-22.3.
- Is the Mainline ML24HP230NEXH-O good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,200 BTU/h at 5°F with a COP of 2.23, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the Mainline ML24HP230NEXH-O cost to run per year?
- At its rated efficiency it costs about $484-$1,247 a year in electricity in large U.S. cities, depending on climate and local rates - for example $590 in Phoenix and $1,036 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Mainline ML24HP230NEXH-O?
- ENERGY STAR lists 10 certified combinations for this outdoor unit. The highest-rated ones use MAINLINE ML24HP230NEX-I, MAINLINE ML24HP230STDCAS-I, MAINLINE ML24HP230FLO-I.
- What refrigerant does the Mainline ML24HP230NEXH-O use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- Convectair 500004496 · cold climate22.3 SEER2 · 13.3 HSPF2
- SLIMAIR SHC24AH2AG · cold climate22.3 SEER2 · 13.3 HSPF2
- ComfortStar CHF3-24CD(O) · cold climate22.3 SEER2 · 13.3 HSPF2
- TRUST AIR CONDITIONERS OAH24H/O6S4P · cold climate22.3 SEER2 · 13.3 HSPF2
- AI AIR CONDITIONING AO25-24N2-M1H · cold climate22.3 SEER2 · 13.3 HSPF2
- ZERO ZMSB-24HV-USHHCR2-O · cold climate22.3 SEER2 · 13.3 HSPF2
- NOVAIR LEA24SZ36-O · cold climate22.3 SEER2 · 13.5 HSPF2
- Airquest DLCSRBH24AAK · cold climate22.3 SEER2 · 11.5 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 19, 2026. How we use the data.