24,000 BTU mini-split heat pump · MSAG series
MDV MOD30-24HFN1-MU0W
Average cooling efficiency and very good heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #164 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $571 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.3 Cooling efficiency over a seasonAverage · beats 53%
- HSPF2
- 11.5 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 27,000 BTU/h88% of its 47°F outputVery good · beats 81%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 27,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 19 certified pairings.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Also sold as | Alsetria, ECO-AIR, DIRECT AIR |
| Outdoor unit model | MOD30-24HFN1-MU0W |
| Series | MSAG series |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | December 18, 2019 |
| Last certified | June 25, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.3 (range 15.2-22.3) |
| EER2Efficiency at 95°F outdoors | 11.0-13.0 |
| Cooling capacity | 21,600-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-11.5 |
| Capacity at 47°F | 23,400-29,000 BTU/h |
| Capacity at 17°F | 16,500-22,000 BTU/h |
| Capacity at 5°F | 21,200-27,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.70-2.21 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MSAG11D-23HRFN1-MU0W at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MSAG11D-23HRFN1-MU0W · cold climate | 22.3 | 12.5 | 10.3 | 23,000 | 206361863 |
| MSEPD-24HRFN1-MU0W · cold climate | 21.5 | 13.0 | 11.4 | 25,000 | 205993855 |
| MSEPD-24HRFN1-MU0W ECO-AIR · cold climate | 21.5 | 13.0 | 11.4 | 25,000 | 208121867 |
| MSEPD-24HRFN1-MU0W Alsetria · cold climate | 21.5 | 13.0 | 11.4 | 25,000 | 208121904 |
| MCD1-24HRFN1-MT0W(GA) · cold climate | 20.5 | 11.0 | 11.5 | 25,800 | 207338219 |
| MCD1-24HRFN1-MT0W(GA) Alsetria · cold climate | 20.5 | 11.0 | 11.5 | 25,800 | 211644046 |
| MCD1-24HRFN1-MT0W(GA) ECO-AIR · cold climate | 20.5 | 11.0 | 11.5 | 25,800 | 211644071 |
| MUEU-24HRFN1-M(C) · cold climate | 20.5 | 11.7 | 11.0 | 25,000 | 206330134 |
| MTI-24HWFN1-MSP5 · cold climate | 19.2 | 12.0 | 11.1 | 24,000 | 210299844 |
| MTIU-24HWFN1-M · cold climate | 19.2 | 12.0 | 10.5 | 27,000 | 206330136 |
| MTIU-24HWFN1-M Alsetria · cold climate | 19.2 | 12.0 | 10.5 | 27,000 | 211644040 |
| MTIU-24HWFN1-M ECO-AIR · cold climate | 19.2 | 12.0 | 10.5 | 27,000 | 211644065 |
| CS11M-23HRFN1-MT0W · cold climate | 18.9 | 11.7 | 10.4 | 23,400 | 205746255 |
| CS11M-23HRFN1-MT0W DIRECT AIR · cold climate | 18.9 | 11.7 | 10.4 | 23,400 | 205816492 |
| MVC-23HWFN1-M · cold climate | 18.4 | 11.7 | 9.3 | 21,200 | 207802615 |
| MVC-23HWFN1-M · cold climate | 18.4 | 11.7 | 9.3 | 21,200 | 211644107 |
| MVC-23HWFN1-M · cold climate | 18.4 | 11.7 | 9.3 | 21,200 | 211644113 |
| MVB-24HWFN1-M | 16.6 | 11.0 | 8.5 | 22,000 | 207742580 |
| MAC-24HWDN1-MN0-N · cold climate | 15.2 | 11.7 | 9.8 | 23,000 | 210321397 |
Yearly running cost in 10 large cities
- Phoenix, AZ$626/yr
- Miami, FL$506/yr
- Houston, TX$561/yr
- Atlanta, GA$571/yr
- Los Angeles, CA$557/yr
- New York, NY$1,369/yr
- Chicago, IL$1,112/yr
- Denver, CO$925/yr
- Seattle, WA$569/yr
- Minneapolis, MN$1,146/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOD30-24HFN1-MU0W?
- The MDV MOD30-24HFN1-MU0W is rated at up to 22.3 SEER2 and 12.5 EER2 for cooling and up to 11.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 19 certified matchups SEER2 ranges from 15.2-22.3.
- Is the MDV MOD30-24HFN1-MU0W good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 27,000 BTU/h at 5°F with a COP of 2.21, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOD30-24HFN1-MU0W cost to run per year?
- At its rated efficiency it costs about $506-$1,369 a year in electricity in large U.S. cities, depending on climate and local rates - for example $626 in Phoenix and $1,146 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOD30-24HFN1-MU0W?
- ENERGY STAR lists 19 certified combinations for this outdoor unit. The highest-rated ones use MSAG11D-23HRFN1-MU0W, MSEPD-24HRFN1-MU0W, ECO-AIR MSEPD-24HRFN1-MU0W.
- What refrigerant does the MDV MOD30-24HFN1-MU0W use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- LBG Products LBHB24DVWO · cold climate22.3 SEER2 · 11.5 HSPF2
- Mitsutomo HO-SZ24-AB-Q · cold climate22.3 SEER2 · 11.5 HSPF2
- KARDA 3KARDA24SZO · cold climate22.3 SEER2 · 11.5 HSPF2
- PerfectAire 3PAMSHH24-SZO · cold climate22.3 SEER2 · 11.5 HSPF2
- Cooper&Hunter CH-HPR24-230VO · cold climate22.3 SEER2 · 11.5 HSPF2
- NOVAIR LEA24SZ35SK-O · cold climate22.3 SEER2 · 11.4 HSPF2
- Breeze33 HSZ24H424ZMO · cold climate22.3 SEER2 · 11.5 HSPF2
- Goodman MSH243G22MCAA · cold climate22.3 SEER2 · 10.5 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 25, 2026. How we use the data.