30,000 BTU mini-split heat pump · MSAG series
MDV M3OJ-27HFN1-M
Very good cooling efficiency and below average heating efficiency for a 30,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #12 of 171 30,000 BTU mini-splits for cooling efficiency, and costs about $712 a year to run in a mixed climate like Atlanta.
- SEER2
- 24.6 Cooling efficiency over a seasonVery good · beats 80%
- HSPF2
- 9.5 Heating efficiency over a seasonBelow average · beats 24%
- EER2
- 12.7 Cooling efficiency on a 95°F dayAverage · beats 54%
- Heat at 5°F
- 19,000 BTU/h68% of its 47°F outputAverage · beats 48%
A good fit if…
- You want low cooling bills - its SEER2 beats 80% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 18 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Also sold as | ECO-AIR, Alsetria, Midea |
| Outdoor unit model | M3OJ-27HFN1-M |
| Series | MSAG series |
| Type | Mini-split heat pump |
| Nominal size | 30,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | June 1, 2022 |
| Last certified | April 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 24.6 (range 20.0-24.6) |
| EER2Efficiency at 95°F outdoors | 11.5-12.7 |
| Cooling capacity | 27,000-28,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-9.5 |
| Capacity at 47°F | 27,000-28,000 BTU/h |
| Capacity at 17°F | 19,000-22,000 BTU/h |
| Capacity at 5°F | 16,400-19,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - | 24.6 | 12.7 | 9.5 | 19,000 | 206714975 |
| - ECO-AIR | 24.6 | 12.7 | 9.5 | 19,000 | 208121871 |
| - Alsetria | 24.6 | 12.7 | 9.5 | 19,000 | 208121908 |
| - | 23.5 | 12.2 | 9.2 | 19,000 | 207641252 |
| - MIDEA | 23.5 | 12.2 | 9.2 | 19,000 | 207683283 |
| - | 22.8 | 12.2 | 9.4 | 18,800 | 206716989 |
| - ECO-AIR | 22.8 | 12.2 | 9.4 | 18,800 | 208121873 |
| - Alsetria | 22.8 | 12.2 | 9.4 | 18,800 | 208121910 |
| - | 22.3 | 12.0 | 9.2 | 18,800 | 207641254 |
| - MIDEA | 22.3 | 12.0 | 9.2 | 18,800 | 207683284 |
| - | 21.0 | 11.7 | 9.2 | 18,700 | 207641243 |
| - | 21.0 | 11.7 | 9.2 | 18,700 | 206714981 |
| - | 21.0 | 11.7 | 9.2 | 18,700 | 213257499 |
| - ECO-AIR | 21.0 | 11.7 | 9.2 | 18,700 | 208121872 |
| - Alsetria | 21.0 | 11.7 | 9.2 | 18,700 | 208121909 |
| - MIDEA | 21.0 | 11.7 | 9.2 | 18,700 | 207683282 |
| - | 20.5 | 11.6 | 8.9 | 17,500 | 213257505 |
| - | 20.0 | 11.5 | 8.5 | 16,400 | 213257498 |
Yearly running cost in 10 large cities
- Phoenix, AZ$712/yr
- Miami, FL$540/yr
- Houston, TX$640/yr
- Atlanta, GA$712/yr
- Los Angeles, CA$707/yr
- New York, NY$1,779/yr
- Chicago, IL$1,459/yr
- Denver, CO$1,226/yr
- Seattle, WA$763/yr
- Minneapolis, MN$1,522/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV M3OJ-27HFN1-M?
- The MDV M3OJ-27HFN1-M is rated at up to 24.6 SEER2 and 12.7 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 18 certified matchups SEER2 ranges from 20.0-24.6.
- Is the MDV M3OJ-27HFN1-M good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 30,000 BTU model.
- How much does the MDV M3OJ-27HFN1-M cost to run per year?
- At its rated efficiency it costs about $540-$1,779 a year in electricity in large U.S. cities, depending on climate and local rates - for example $712 in Phoenix and $1,522 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the MDV M3OJ-27HFN1-M use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 30,000 BTU models
- Kaden KO-PS327HP-2AAMA24.6 SEER2 · 9.5 HSPF2
- MRCOOL MULTI3-27HP230B24.6 SEER2 · 9.5 HSPF2
- DIYCOOL ES-27Z-M3B24.6 SEER2 · 9.5 HSPF2
- Armstrong Air 4DHP2S30M-1P24.6 SEER2 · 9.3 HSPF2
- DIRECT AIR DIRM-27DA25-3Z24.6 SEER2 · 9.5 HSPF2
- Lennox MPC030S4M-1P24.6 SEER2 · 9.3 HSPF2
- C&H CH-28MES-230VO24.6 SEER2 · 9.5 HSPF2
- TOSHIBA CARRIER RAV-BP301AT2P-UL · cold climate24.5 SEER2 · 11.8 HSPF2
See all 171 30,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 27, 2026. How we use the data.