3-ton central heat pump · MVB Series
MDV MOD30-36HFN10-M3
Average cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #188 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,064 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.7 Cooling efficiency over a seasonAverage · beats 43%
- HSPF2
- 9.3 Heating efficiency over a seasonAverage · beats 62%
- EER2
- 10.2 Cooling efficiency on a 95°F dayBelow average · beats 15%
- Heat at 5°F
- 29,200 BTU/h79% of its 47°F outputBelow average · beats 39%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 29,200 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 18 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Outdoor unit model | MOD30-36HFN10-M3 |
| Series | MVB Series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 12, 2022 |
| Last certified | August 5, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.7 (range 15.2-16.7) |
| EER2Efficiency at 95°F outdoors | 9.2-10.2 |
| Cooling capacity | 35,000-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-9.3 |
| Capacity at 47°F | 35,000-37,000 BTU/h |
| Capacity at 17°F | 23,000-27,000 BTU/h |
| Capacity at 5°F | 26,000-29,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVBE-36HWFN10-WL3E at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| MVBE-36HWFN10-WL3E · cold climate | - | 16.7 | 10.2 | 9.3 | 29,200 | 215894241 |
| MVBE-36HWFN10-WL3E-MAS · cold climate | - | 16.7 | 10.2 | 9.3 | 29,200 | 216030946 |
| MVBC-36HWFN10-MC3E · cold climate | - | 16.2 | 10.0 | 8.7 | 27,000 | 214861554 |
| MVBC-36HWFPN10-MC3E · cold climate | - | 16.2 | 10.0 | 8.7 | 27,000 | 215865885 |
| MVBC-36HWFN10-MC3E-D · cold climate | - | 16.1 | 10.0 | 8.7 | 27,000 | 214861600 |
| MVBC-36HWFN10-MC3E-MAS · cold climate | - | 16.1 | 10.0 | 8.7 | 27,000 | 216030939 |
| MVBM-36C24T4N10 · cold climate | RL18100C20MPS1 | 15.7 | 10.1 | 8.5 | 26,000 | 217753604 |
| MVBM-36C24T4N10 · cold climate | S9V2C100D5VS*** | 15.6 | 9.9 | 8.5 | 26,000 | 217753391 |
| MVBM-36C24T4N10 · cold climate | S9V2C100U5VS*** | 15.6 | 9.9 | 8.5 | 26,000 | 217753392 |
| MVBM-36C24T4N10 · cold climate | RL18100C16MPS1 | 15.6 | 10.0 | 8.4 | 26,000 | 217753603 |
| MVBM-36C24T4N10 · cold climate | RL18080C16MPS1 | 15.6 | 9.6 | 8.3 | 26,000 | 217753602 |
| MVBM-36C24T4N10 · cold climate | ML296UH110XV60C* | 15.5 | 9.9 | 8.5 | 26,000 | 217754175 |
| MVBL-36HWFN10-WK3 · cold climate | - | 15.4 | 9.2 | 8.7 | 28,400 | 216620323 |
| MVBM-36B24T4N10 · cold climate | MGV96U060B3C | 15.4 | 9.5 | 8.2 | 26,000 | 217607694 |
| MVBM-36B24T4N10 · cold climate | RL18080B12MPS1 | 15.4 | 9.3 | 8.2 | 26,000 | 217753601 |
| MVBM-36C24T4N10 · cold climate | RG19080C16MPS1 | 15.4 | 9.5 | 8.1 | 26,000 | 217753547 |
| MVBM-36C24T4N10 · cold climate | S9V2C080U5VS*** | 15.3 | 9.8 | 8.6 | 26,000 | 217753390 |
| MVBM-36B24T4N10 · cold climate | RG19080B12MPS1 | 15.2 | 9.3 | 8.4 | 27,000 | 217753546 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,217/yr
- Miami, FL$1,010/yr
- Houston, TX$1,089/yr
- Atlanta, GA$1,064/yr
- Los Angeles, CA$1,027/yr
- New York, NY$2,496/yr
- Chicago, IL$2,017/yr
- Denver, CO$1,670/yr
- Seattle, WA$1,020/yr
- Minneapolis, MN$2,063/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOD30-36HFN10-M3?
- The MDV MOD30-36HFN10-M3 is rated at up to 16.7 SEER2 and 10.2 EER2 for cooling and up to 9.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 18 certified matchups SEER2 ranges from 15.2-16.7.
- Is the MDV MOD30-36HFN10-M3 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 29,200 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOD30-36HFN10-M3 cost to run per year?
- At its rated efficiency it costs about $1,010-$2,496 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,217 in Phoenix and $2,063 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOD30-36HFN10-M3?
- ENERGY STAR lists 18 certified combinations for this outdoor unit. The highest-rated ones use MVBE-36HWFN10-WL3E, MVBE-36HWFN10-WL3E-MAS, MVBC-36HWFN10-MC3E.
- What refrigerant does the MDV MOD30-36HFN10-M3 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Mainline ML36HP230LMNT-O · cold climate16.7 SEER2 · 9.3 HSPF2
- Midea MO1BE-H36B-2A · cold climate16.7 SEER2 · 9.3 HSPF2
- Innovair SOV36H2BA · cold climate16.7 SEER2 · 9.3 HSPF2
- MOOVAIR MSHEA36R2AN1 · cold climate16.7 SEER2 · 9.3 HSPF2
- Elios ESHEA36R2AN1 · cold climate16.7 SEER2 · 9.3 HSPF2
- MRCOOL MHP17L36P-**A16.6 SEER2 · 8.7 HSPF2
- DuraSTAR DRU1U36S2A · cold climate16.7 SEER2 · 9.3 HSPF2
- MRCOOL MHP17036A-**A16.6 SEER2 · 8.1 HSPF2
See all 302 3 ton central heat pumps, ranked