3-ton central heat pump · MHP17 SERIES
MRCOOL MHP17036A-**A
Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.
Ranks #192 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,108 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.6 Cooling efficiency over a seasonAverage · beats 42%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 13.5 Cooling efficiency on a 95°F dayExcellent · beats 95%
- Heat at 5°F
- 17,600 BTU/h53% of its 47°F outputVery good · beats 81%
A good fit if…
- You want a choice of indoor units - 13 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | MRCOOL |
| Outdoor unit model | MHP17036A-**A |
| Series | MHP17 SERIES |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 25, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.6 (range 15.6-16.6) |
| EER2Efficiency at 95°F outdoors | 12.2-13.5 |
| Cooling capacity | 35,400-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 32,800-34,200 BTU/h |
| Capacity at 17°F | 21,600-22,400 BTU/h |
| Capacity at 5°F | 16,800-17,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.08-2.24 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MCHP51CNPA*+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| MCHP51CNPA*+TDR+TXV | MGM80SE090C5A | 16.6 | 13.5 | 8.0 | 17,400 | 211736684 |
| MCVP36BNPA+TDR+TXV | MGM80SE090B4A | 16.6 | 13.5 | 7.8 | 16,800 | 210441078 |
| MCVP36ANPA+TDR+TXV | MGM80SE090B4A | 16.6 | 13.5 | 7.8 | 16,800 | 210326081 |
| MCHP51CNPA*+TDR+TXV | MGM80SE110C5A | 16.4 | 13.0 | 8.1 | 17,400 | 211736701 |
| MCHP51CNPA*+TDR+TXV | MGM96SE110C5XA | 16.4 | 13.0 | 8.0 | 17,500 | 211736795 |
| MCHP48BNPA*+TDR+TXV | MGM80SE090B4A | 16.2 | 13.0 | 8.0 | 17,200 | 211736412 |
| MCHP51CNPA*+TDR+TXV | MGM96SE090C4XA | 16.2 | 13.0 | 8.0 | 17,500 | 211736779 |
| MCVP36ANPA+TDR+TXV | MGM80SE045A3A | 16.0 | 13.0 | 7.8 | 17,000 | 210326063 |
| MCVP36ANPA+TDR+TXV | MGM80SE070B3A | 16.0 | 13.0 | 7.8 | 17,200 | 210326065 |
| MCVP36BNPA+TDR+TXV | MGM96SE070B3XA | 15.8 | 12.5 | 7.8 | 17,000 | 210441079 |
| MCVP36ANPA+TDR+TXV | MGM96SE070B3XA | 15.8 | 12.5 | 7.8 | 17,000 | 210326067 |
| MAHM042CTA | - | 15.6 | 12.2 | 8.1 | 17,600 | 211174412 |
| MCHP48BNPA*+TDR+TXV | MGM96SE070B3XA | 15.6 | 12.5 | 7.8 | 17,400 | 211736487 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,233/yr
- Miami, FL$1,007/yr
- Houston, TX$1,105/yr
- Atlanta, GA$1,108/yr
- Los Angeles, CA$1,076/yr
- New York, NY$2,635/yr
- Chicago, IL$2,136/yr
- Denver, CO$1,774/yr
- Seattle, WA$1,089/yr
- Minneapolis, MN$2,195/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MRCOOL MHP17036A-**A?
- The MRCOOL MHP17036A-**A is rated at up to 16.6 SEER2 and 13.5 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 13 certified matchups SEER2 ranges from 15.6-16.6.
- Is the MRCOOL MHP17036A-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
- How much does the MRCOOL MHP17036A-**A cost to run per year?
- At its rated efficiency it costs about $1,007-$2,635 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,233 in Phoenix and $2,195 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MRCOOL MHP17036A-**A?
- ENERGY STAR lists 13 certified combinations for this outdoor unit. The highest-rated ones use MCHP51CNPA*+TDR+TXV, MCVP36BNPA+TDR+TXV, MCVP36ANPA+TDR+TXV.
- What refrigerant does the MRCOOL MHP17036A-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Carrier 37MUHAQ36AA3+TIC2025-0016 · cold climate16.5 SEER2 · 8.5 HSPF2
- MOOVAIR MSHEA36R2AN1 · cold climate16.7 SEER2 · 9.3 HSPF2
- Heil D5CUHAH36AAK+TIC2025-0016 · cold climate16.5 SEER2 · 8.5 HSPF2
- Midea MO1BE-H36B-2A · cold climate16.7 SEER2 · 9.3 HSPF2
- Heil H5H8T36*K*AAA16.5 SEER2 · 8.5 HSPF2
- MDV MOD30-36HFN10-M3 · cold climate16.7 SEER2 · 9.3 HSPF2
- Kenmore (C,H,T)5H8T36*K*AAA16.5 SEER2 · 8.5 HSPF2
- Mainline ML36HP230LMNT-O · cold climate16.7 SEER2 · 9.3 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.