HVAC Rated

3-ton central heat pump · Mainline 18 SEER2 HP

Heil H5H8T36*K*AAA

Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #195 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,176 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
19,600 BTU/h50% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want a choice of indoor units - 564 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, Comfortmaker, Keeprite, Day & Night
Outdoor unit modelH5H8T36*K*AAA
SeriesMainline 18 SEER2 HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity33,800-38,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F37,200-39,000 BTU/h
Capacity at 17°F23,000-24,200 BTU/h
Capacity at 5°F17,500-19,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.84-2.40
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTMA5B48L0C at the standard test temperatures, in BTU/h:

Certified matchups564 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 564 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FTMA5B48L0C-16.512.58.118,700216360591
FTMA5B48L0C-16.512.58.118,700216360592
FTMA5B48L0C-16.512.58.118,700216360593
QFVA5D4821X-16.513.08.118,400218695608
QFVA5D4821X-16.513.08.118,400218695607
QFVA5D4821X-16.513.08.118,400218695606
EA*5X43M21A*80MSU0802120A*16.012.08.519,100216358215
EA*5X43M21A*80MSU0802120A*16.012.08.519,100216358216
EA*5X43M21A*80MSU0802120A*16.012.08.519,100216358217
EA*5X43M21A*+WALLCON*80CSU0802120B*16.012.08.519,200216358535
EA*5X43M21A*+WALLCON*80CSU0802120B*16.012.08.519,200216358536
EA*5X43M21A*+WALLCON*80CSU0802120B*16.012.08.519,200216358537
EA*5X37M21A*80MSU0601716A*16.012.08.119,300216357255
EA*5X37M21A*80MSU0601716A*16.012.08.119,300216357256
EA*5X37M21A*80MSU0601716A*16.012.08.119,300216357257
EA*5X43M21A*80MSU0601716A*16.012.08.119,300216358207
EA*5X43M21A*80MSU0601716A*16.012.08.119,300216358208
EA*5X43M21A*80MSU0601716A*16.012.08.119,300216358209
QFVA5D3617X-16.012.58.118,300218695601
QFVA5D3617X-16.012.58.118,300218695600
QFVA5D3617X-16.012.58.118,300218695599
EA*5X43M21A*+WALLCON*80CSU0802120A*16.012.08.019,300216358151
EA*5X43M21A*+WALLCON*80CSU0802120A*16.012.08.019,300216358152
EA*5X43M21A*+WALLCON*80CSU0802120A*16.012.08.019,300216358153
FCMA5B48L0C*+WALLCON-16.013.08.018,900216360607
FCMA5B48L0C*+WALLCON-16.013.08.018,900216360608
FCMA5B48L0C*+WALLCON-16.013.08.018,900216360609
EA*5X37M21A*+WALLCON*80CSU0802120B*16.012.08.019,300216357575
EA*5X37M21A*+WALLCON*80CSU0802120B*16.012.08.019,300216357576
EA*5X37M21A*+WALLCON*80CSU0802120B*16.012.08.019,300216357577
EVM5X48M21A*80MSU0802120A*16.012.57.817,500216354471
EVM5X48M21A*80MSU0802120A*16.012.57.817,500216354472
EVM5X48M21A*80MSU0802120A*16.012.57.817,500216354473
EVM5X49M21A*80MSU0802120A*16.012.57.817,700216354735
EVM5X49M21A*80MSU0802120A*16.012.57.817,700216354736
EVM5X49M21A*80MSU0802120A*16.012.57.817,700216354737
EVD5X38M17A*80VSL0901716B*16.012.57.817,600216355607
EVD5X38M17A*80VSL0901716B*16.012.57.817,600216355608
EVD5X38M17A*80VSL0901716B*16.012.57.817,600216355609
EVD5X38M17A*80MSU0401712A*16.012.57.817,600216355615
EVD5X38M17A*80MSU0401712A*16.012.57.817,600216355616
EVD5X38M17A*80MSU0401712A*16.012.57.817,600216355617
EVD5X38M17A*80MSU0601716A*16.012.57.817,600216355623
EVD5X38M17A*80MSU0601716A*16.012.57.817,600216355624
EVD5X38M17A*80MSU0601716A*16.012.57.817,600216355625
EA*5X48M21A*80VSL0902120B*15.511.78.119,200216358671
EA*5X48M21A*80VSL0902120B*15.511.78.119,200216358672
EA*5X48M21A*80VSL0902120B*15.511.78.119,200216358673
EA*5X48M21A*80VSL1102122B*15.512.08.119,100216358679
EA*5X48M21A*80VSL1102122B*15.512.08.119,100216358680
EA*5X48M21A*80VSL1102122B*15.512.08.119,100216358681
EA*5X48M21A*80MSU0401712A*15.511.78.119,200216358687
EA*5X48M21A*80MSU0401712A*15.511.78.119,200216358688
EA*5X48M21A*80MSU0401712A*15.511.78.119,200216358689
EA*5X48M21A*80MSU0601716A*15.512.08.119,000216358695
EA*5X48M21A*80MSU0601716A*15.512.08.119,000216358696
EA*5X48M21A*80MSU0601716A*15.512.08.119,000216358697
EA*5X48M21A*80MSU0802120A*15.512.08.119,000216358703
EA*5X48M21A*80MSU0802120A*15.512.08.119,000216358704
EA*5X48M21A*80MSU0802120A*15.512.08.119,000216358705
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Heil H5H8T36*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,021-$2,835

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Heil H5H8T36*K*AAA?
The Heil H5H8T36*K*AAA is rated at up to 16.5 SEER2 and 12.5 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 564 certified matchups SEER2 ranges from 15.2-16.5.
Is the Heil H5H8T36*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Heil H5H8T36*K*AAA cost to run per year?
At its rated efficiency it costs about $1,021-$2,835 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,273 in Phoenix and $2,380 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Heil H5H8T36*K*AAA the same as the Comfortmaker C5H8T36*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Heil H5H8T36*K*AAA?
ENERGY STAR lists 564 certified combinations for this outdoor unit. The highest-rated ones use FTMA5B48L0C, QFVA5D4821X, EA*5X43M21A.
What refrigerant does the Heil H5H8T36*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,271/yrYou save $619/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H8T36*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,271
Current system, per year
$1,890
You save per year
$619
Payback
21.8 years
Net after 10 years
-$7,309

Cooling $764Heating $507Electricity used: 7,944 kWhSaved vs. a minimum-efficiency heat pump: $185

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.