HVAC Rated

3-ton central heat pump · QUIETCOMFORT DELUXE 23 VS HP

Heil H5H3V36*K*AAA

Excellent cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #5 of 302 3 ton central heat pumps for cooling efficiency, and costs about $956 a year to run in a mixed climate like Atlanta.

SEER2
22.5 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
29,600 BTU/h75% of its 47°F output
Average · beats 67%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 29,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, ACIQ
Outdoor unit modelH5H3V36*K*AAA
SeriesQUIETCOMFORT DELUXE 23 VS HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better22.5 (range 18.0-22.5)
EER2Efficiency at 95°F outdoors10.0-13.0
Cooling capacity32,000-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.5
Capacity at 47°F33,400-39,500 BTU/h
Capacity at 17°F29,200-34,800 BTU/h
Capacity at 5°F25,200-29,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.88-2.14
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVD5X61M24A*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups2,256 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 2,256 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200215936926
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200215936928
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200215936927
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200215936936
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200215936938
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200215936937
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200215936947
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200215936946
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200215936948
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200215935456
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200215935457
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200215935458
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200215935466
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200215935467
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200215935468
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200215935476
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200215935477
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200215935478
EVM5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200215935486
EVM5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200215935487
EVM5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200215935488
EVM5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200216635630
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200216635628
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200216635629
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200216635627
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200216635775
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200216635776
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200216635774
FCMA5B60L0D*+WALLCON · cold climate-22.013.09.525,200215933966
FCMA5B60L0D*+WALLCON · cold climate-22.013.09.525,200215933967
FCMA5B60L0D*+WALLCON · cold climate-22.013.09.525,200215933968
FCMA5B60L0D*+WALLCON · cold climate-22.013.09.525,200216635478
EVD5X61M21A*+WALLCON · cold climate*80CTL0701716B*22.012.09.028,600215936876
EVD5X61M21A*+WALLCON · cold climate*80CTL0701716B*22.012.09.028,600215936877
EVD5X61M21A*+WALLCON · cold climate*80CTL0701716B*22.012.09.028,600215936878
EVD5X60M21A*+WALLCON · cold climate*95CSU1002122B*22.012.59.028,400215936666
EVD5X60M21A*+WALLCON · cold climate*95CSU1002122B*22.012.59.028,400215936667
EVD5X60M21A*+WALLCON · cold climate*95CSU1002122B*22.012.59.028,400215936668
EVD5X60M21A*+WALLCON · cold climate*95CSU1002122B*22.012.59.028,400216635748
EVD5X61M21A*+WALLCON · cold climate*80CTL0701716B*22.012.09.028,600216635769
EVM5X49M21A*+WALLCON · cold climate*95CSU1002122B*22.012.58.528,400215935076
EVM5X49M21A*+WALLCON · cold climate*95CSU1002122B*22.012.58.528,400215935077
EVM5X49M21A*+WALLCON · cold climate*95CSU1002122B*22.012.58.528,400215935078
EVM5X49M21A*+WALLCON · cold climate*97CMN1002122B*22.012.58.528,600215935116
EVM5X49M21A*+WALLCON · cold climate*97CMN1002122B*22.012.58.528,600215935117
EVM5X49M21A*+WALLCON · cold climate*97CMN1002122B*22.012.58.528,600215935118
EVD5X60M24A*+WALLCON · cold climate*80CTL0902120B*22.012.58.528,400215936756
EVD5X60M24A*+WALLCON · cold climate*80CTL0902120B*22.012.58.528,400215936757
EVD5X60M24A*+WALLCON · cold climate*80CTL0902120B*22.012.58.528,400215936758
EVD5X60M24A*+WALLCON · cold climate*80CTL1102120B*22.012.58.528,400215936766
EVD5X60M24A*+WALLCON · cold climate*80CTL1102120B*22.012.58.528,400215936767
EVD5X60M24A*+WALLCON · cold climate*80CTL1102120B*22.012.58.528,400215936768
EVD5X60M24A*+WALLCON · cold climate*80CTL1352422B*22.012.58.528,400215936776
EVD5X60M24A*+WALLCON · cold climate*80CTL1352422B*22.012.58.528,400215936777
EVD5X60M24A*+WALLCON · cold climate*80CTL1352422B*22.012.58.528,400215936778
EVD5X60M24A*+WALLCON · cold climate*95CSU1002122B*22.012.58.528,400215936796
EVD5X60M24A*+WALLCON · cold climate*95CSU1002122B*22.012.58.528,400215936797
EVD5X60M24A*+WALLCON · cold climate*95CSU1002122B*22.012.58.528,400215936798
EVD5X61M21A*+WALLCON · cold climate*95CSU1002122B*22.012.58.528,400215936886
EVD5X61M21A*+WALLCON · cold climate*95CSU1002122B*22.012.58.528,400215936887
Yearly running cost in 10 large cities$726-$2,389

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Heil H5H3V36*K*AAA?
The Heil H5H3V36*K*AAA is rated at up to 22.5 SEER2 and 12.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2256 certified matchups SEER2 ranges from 18.0-22.5.
Is the Heil H5H3V36*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 29,600 BTU/h at 5°F with a COP of 2.14, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Heil H5H3V36*K*AAA cost to run per year?
At its rated efficiency it costs about $726-$2,389 a year in electricity in large U.S. cities, depending on climate and local rates - for example $957 in Phoenix and $2,044 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Heil H5H3V36*K*AAA?
ENERGY STAR lists 2256 certified combinations for this outdoor unit. The highest-rated ones use EVD5X61M24A*+WALLCON, EVM5X61M24A*+WALLCON, FCMA5B60L0D*+WALLCON.
What refrigerant does the Heil H5H3V36*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $981/yrYou save $845/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H3V36*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$981
Current system, per year
$1,826
You save per year
$845
Payback
15.4 years
Net after 10 years
-$4,553

Cooling $538Heating $443Electricity used: 6,134 kWhSaved vs. a minimum-efficiency heat pump: $427

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.