HVAC Rated

3-ton central heat pump · 16 Single-Stage Heat Pump

Trane 5TWR6036A1

Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #199 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,010 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
17,600 BTU/h54% of its 47°F output
Excellent · beats 98%

A good fit if…

  • You want a choice of indoor units - 371 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model5TWR6036A1
Series16 Single-Stage Heat Pump
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 16, 2026
Last certifiedJune 12, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.5-12.0
Cooling capacity31,600-35,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F29,800-32,200 BTU/h
Capacity at 17°F21,000-22,200 BTU/h
Capacity at 5°F16,900-17,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.23-2.49
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TEMCD07AV51+TDR+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups371 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 371 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TEMCD07AV51+TDR+TSTAT-16.512.08.117,000218107906
5TEMCD05AV41+TDR+TSTAT-16.012.08.517,000218107902
5TEM6D04AV31+TDR+TSTAT-16.012.08.517,500218107890
5PX*C009AS3+TSTATS9X1C080U5PSB16.012.08.117,200218107714
5PX*C009AS3+TSTATS9V2C100U4VSB16.012.08.116,900218107712
5PX*C009AS3+TSTATS8X2C100M5PTC16.012.08.117,300218107710
5PX*C009AS3+TSTATS8X2C080M5PTC16.012.08.117,200218107708
5PX*C009AS3+TSTATS8X1C100M5PTC16.012.08.117,300218107706
5PX*C009AS3+TSTATS8X1C080M5PTC16.012.08.117,200218107704
5PX*C009AS3+TSTATS8V2C100M5PDB16.012.08.117,200218107702
5PX*C009AS3+TSTATS8V2C080M5PDB16.012.08.117,100218107700
5PX*C009AS3+TSTAT+P0V0C000M50SD-16.012.08.116,900218107698
5PX*C009AS3+TSTATL8V1C100U5VSB16.012.08.117,000218107696
5PX*C009AS3+TSTATS9V2C100U5VSB16.012.08.116,900218107694
5PX*C009AS3+TSTATS9V2C080U5VSB16.012.08.117,200218107692
5PX*C009AS3+TSTATS8X2C100M5PSC16.012.08.117,300218107690
5PX*C009AS3+TSTATS8X2C080M5PSC16.012.08.117,200218107688
5PX*C009AS3+TSTATS8X1C100M5PSC16.012.08.117,300218107686
5PX*C009AS3+TSTATS8X1C080M5PSC16.012.08.117,200218107684
5PX*C009AS3+TSTATS8V2C100M5PCB16.012.08.117,200218107682
5PX*C009AS3+TSTATS8V2C080M5PCB16.012.08.117,100218107680
5PX*C009AS3+TSTAT*UHMC100CCV416.012.08.116,900218107678
5PX*C009AS3+TSTATS9X2C080U5PSB16.012.08.117,200218107676
5PX*C007AS3+TSTATS8X2C080M5PSC16.012.08.117,400218107672
5PX*C007AS3+TSTATS8X1C100M5PSC16.012.08.117,400218107670
5PX*C007AS3+TSTATS8X1C080M5PSC16.012.08.117,400218107668
5PX*C007AS3+TSTATS8V2C100M5PCB16.012.08.117,300218107666
5PX*C007AS3+TSTAT*UHMC100CCV416.012.08.117,000218107664
5PX*C007AS3+TSTATS9V2C100U5VSB16.012.08.117,000218107658
5PX*C007AS3+TSTATS9V2C080U5VSB16.012.08.117,100218107656
5PX*C007AS3+TSTATS8X2C100M5PSC16.012.08.117,400218107654
5PX*C007AS3+TSTATS9X2C080U5PSB16.012.08.117,300218107652
5PX*C007AS3+TSTATS9X1C080U5PSB16.012.08.117,300218107650
5PX*C007AS3+TSTATS9V2C100U4VSB16.012.08.117,000218107648
5PX*C007AS3+TSTATS8X2C100M5PTC16.012.08.117,400218107646
5PX*C007AS3+TSTATS8X2C080M5PTC16.012.08.117,400218107644
5PX*C007AS3+TSTATS8X1C100M5PTC16.012.08.117,400218107642
5PX*C007AS3+TSTATS8X1C080M5PTC16.012.08.117,400218107640
5PX*C007AS3+TSTATS8V2C100M5PDB16.012.08.117,300218107638
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.012.08.117,100218107636
5PX*C007AS3+TSTATL8V1C100U5VSB16.012.08.117,200218107634
5PX*BD06AS3+TSTATS8X2B060M4PTC16.012.08.117,200218107574
5PX*BD06AS3+TSTATS8X1B060M4PTC16.012.08.117,200218107568
5PX*BD06AS3+TSTAT+P0V0B000M40SD-16.012.08.117,100218107558
5PX*BD06AS3+TSTATS8X2B060M4PSC16.012.08.117,200218107546
5PX*BD06AS3+TSTATS8X1B060M4PSC16.012.08.117,200218107540
5PX*B006AS3+TSTAT+P0V0B000M40SD-16.012.08.117,100218107456
5TXCD010AS3+TSTATS8V2D120M5PDB16.012.08.117,100218108206
5TXCD010AS3+TSTATS8X2D120M5PTC16.012.08.117,300218108200
5TXCD010AS3+TSTATS8X1D120M5PTC16.012.08.117,300218108198
5TXCD010AS3+TSTATS8X2D120M5PSC16.012.08.117,300218108196
5TXCD010AS3+TSTATS8X1D120M5PSC16.012.08.117,300218108194
5TXCD010AS3+TSTATS8V2D120M5PCB16.012.08.117,100218108192
5TXCD010AS3+TSTAT*UHMD120CCV516.012.08.117,000218108190
5TXCD010AS3+TSTATS9V2D120U5VSB16.012.08.117,200218108188
5TXCD008AS3+TSTATS9V2D120U5VSB16.012.08.117,200218108186
5TXCD008AS3+TSTATS8X2D120M5PSC16.012.08.117,400218108184
5TXCD008AS3+TSTATS8X1D120M5PSC16.012.08.117,400218108182
5TXCD008AS3+TSTATS8V2D120M5PCB16.012.08.117,200218108180
5TXCD008AS3+TSTAT*UHMD120CCV516.012.08.117,000218108178
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 5TWR6036A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$960-$2,368

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 5TWR6036A1?
The Trane 5TWR6036A1 is rated at up to 16.5 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 371 certified matchups SEER2 ranges from 15.2-16.5.
Is the Trane 5TWR6036A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Trane 5TWR6036A1 cost to run per year?
At its rated efficiency it costs about $960-$2,368 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,155 in Phoenix and $1,957 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 5TWR6036A1 the same as the American Standard 5A6H6036A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 5TWR6036A1?
ENERGY STAR lists 371 certified combinations for this outdoor unit. The highest-rated ones use 5TEMCD07AV51+TDR+TSTAT, 5TEMCD05AV41+TDR+TSTAT, 5TEM6D04AV31+TDR+TSTAT.
What refrigerant does the Trane 5TWR6036A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,132/yrYou save $568/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWR6036A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,132
Current system, per year
$1,700
You save per year
$568
Payback
22.0 years
Net after 10 years
-$6,819

Cooling $721Heating $411Electricity used: 7,076 kWhSaved vs. a minimum-efficiency heat pump: $166

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 12, 2026. How we use the data.