HVAC Rated

3-ton central heat pump · 15 Single-Stage Heat Pump with WeatherGuard Top

Trane 5TWX5036A1

Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #200 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,014 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
17,700 BTU/h55% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want a choice of indoor units - 444 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandTrane
Outdoor unit model5TWX5036A1
Series15 Single-Stage Heat Pump with WeatherGuard Top
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 1, 2024
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity31,800-35,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F29,800-32,600 BTU/h
Capacity at 17°F20,800-22,200 BTU/h
Capacity at 5°F16,600-17,700 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.40
ENERGY STAR cold climateNo
Heating output as it gets colder55% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCD010AS3+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups444 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 444 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCD010AS3+TSTATS9V2D120U5VSB16.512.08.116,900214182663
5TXCD010AS3+TSTATS9V2D120U5PSC16.512.08.116,900214182668
5PX*D010AS3+TSTATS8V2D120M5PCB16.512.08.117,300215687086
5PX*D010AS3+TSTATS8V2D120M5PDB16.512.08.117,300215687087
5PX*D010AS3+TSTATS9V2D120U5PSC16.512.08.117,200215687092
5PX*D010AS3+TSTATS9V2D120U5VSB16.512.08.117,200215687093
5PX*C009AS3+TSTAT+P0V0C000M50SD-16.512.08.117,200215686999
5PX*C009AS3+TSTATL8V1C100U5VSB16.512.08.117,200215687015
5PX*CD09AS3+TSTAT+P0V0C000M50SD-16.512.08.117,200215687062
5TXCC009AS3+TSTATL8V1C100U5VSB16.512.08.117,200215687175
5TXCC009AS3+TSTAT+P0V0C000M50SD-16.512.08.117,200215687178
5TEMCD06AV41+TDR+TSTAT-16.512.08.116,900215863977
5TEMCD07AV51+TDR+TSTAT-16.512.08.116,900215863978
5TEM6D04AV31+TDR+TSTAT-16.012.08.517,500214182337
5TEM6D06AV41+TDR+TSTAT-16.012.08.517,400214182339
5TEM6D07AV51+TDR+TSTAT-16.012.08.517,500214182340
5TXCD008AS3+TSTATS9V2D120U5VSB16.012.08.517,400215687193
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.012.08.517,300215686978
5PX*D008AS3+TSTATS9V2D120U5VSB16.012.08.517,400215687079
5PX*D008AS3+TSTATS9V2D120U5PSC16.012.08.517,400215687083
5TXCD008AS3+TSTATS9V2D120U5PSC16.012.08.517,400215687187
5PX*C007AS3+TSTATS9V2C100U5VSB16.012.08.517,500215831671
5TXCC007AS3+TSTATS9V2C100U5VSB16.012.08.517,600215831683
5TEMCD04AV31+TDR+TSTAT-16.012.08.517,200215863975
5TEMCD05AV41+TDR+TSTAT-16.012.08.517,200215863976
5TXCC007AS3+TSTATS9X2C080U5PSB16.012.08.117,100214182598
5TXCC007AS3+TSTATS9X1C080U5PSB16.012.08.117,100214182602
5TXCC007AS3+TSTATS9V2C100U5PSC16.012.08.117,100214182604
5TXCC007AS3+TSTATS9V2C100U4VSB16.012.08.117,600214182608
5TXCC007AS3+TSTATS9V2C100U4VSA16.012.08.117,100214182610
5TXCC007AS3+TSTATS9V2C080U5PSC16.012.08.117,200214182612
5TXCC007AS3+TSTAT*UHMC100CCV416.012.08.117,100214182629
5TXCC007AS3+TSTATL8V1C100U5VSB16.012.08.117,100214182631
5TXCC007AS3+TSTAT+P0V0C000M50SD-16.012.08.117,000214182637
5TXCC007AS3+TSTATS8V2C100M5PCB16.012.08.117,200214182649
5TXCC007AS3+TSTATS8V2C100M5PDB16.012.08.117,200214182653
5TXCD010AS3+TSTATS9V2D120U5VSA16.012.08.117,300214182666
5TXCD010AS3+TSTATS9V2D120U5PSB16.012.08.116,900214182670
5TXCD010AS3+TSTATS8X2D120M5PTC16.012.08.117,200214182672
5TXCD010AS3+TSTATS8X2D120M5PSC16.012.08.117,200214182674
5TXCD010AS3+TSTATS8X1D120M5PTC16.012.08.117,200214182676
5TXCD010AS3+TSTATS8X1D120M5PSC16.012.08.117,200214182678
5TXCD010AS3+TSTATS8V2D120M5PDB16.012.08.116,900214182680
5TXCD010AS3+TSTAT*UHMD120CCV516.012.08.117,000214182686
5TXCD010AS3+TSTAT*UHMD120ACV516.012.08.117,000214182688
5TXCD010AS3+TSTATS8V2D120M5PCB16.012.08.116,900214182690
5TXCC007AS3+TSTATS8V2C080M5PCB16.012.08.117,200214182641
5TXCC007AS3+TSTATS8V2C080M5PDB16.012.08.117,200214182645
5TXCD008AS3+TSTATS8X1D120M5PTC16.012.08.117,400215687188
5TXCD008AS3+TSTATS8X1D120M5PSC16.012.08.117,400215687189
5TXCD008AS3+TSTATS8V2D120M5PCB16.012.08.117,600215687190
5TXCD008AS3+TSTAT*UHMD120CCV516.012.08.117,300215687192
5TXCD008AS3+TSTATS8V2D120M5PDB16.012.08.117,600215687194
5PX*B006AS3+TSTAT+P0V0B000M40SD-16.012.08.117,500215686850
5PX*B006AS3+TSTATS8X1B060M4PSC16.012.08.117,300215686859
5PX*B006AS3+TSTATS8X1B060M4PTC16.012.08.117,300215686860
5PX*B006AS3+TSTATS8X2B060M4PSC16.012.08.117,300215686865
5PX*B006AS3+TSTAT*UHMB080CCV316.012.08.117,300215686867
5PX*B006AS3+TSTATS8X2B060M4PTC16.012.08.117,300215686872
5PX*BD06AS3+TSTAT+P0V0B000M40SD-16.012.08.117,700215686934
Yearly running cost in 10 large cities$960-$2,380

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 5TWX5036A1?
The Trane 5TWX5036A1 is rated at up to 16.5 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 444 certified matchups SEER2 ranges from 15.2-16.5.
Is the Trane 5TWX5036A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Trane 5TWX5036A1 cost to run per year?
At its rated efficiency it costs about $960-$2,380 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,157 in Phoenix and $1,968 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 5TWX5036A1?
ENERGY STAR lists 444 certified combinations for this outdoor unit. The highest-rated ones use 5TXCD010AS3+TSTAT, 5PX*D010AS3+TSTAT, 5PX*C009AS3+TSTAT+P0V0C000M50SD.
What refrigerant does the Trane 5TWX5036A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,135/yrYou save $569/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWX5036A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,135
Current system, per year
$1,704
You save per year
$569
Payback
22.0 years
Net after 10 years
-$6,813

Cooling $721Heating $414Electricity used: 7,093 kWhSaved vs. a minimum-efficiency heat pump: $166

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.