3-ton central heat pump · MERIT ML14KP1 Series
Lennox ML14KP1-036-230A
Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.
Ranks #202 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,136 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.5 Cooling efficiency over a seasonAverage · beats 40%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 13.8 Cooling efficiency on a 95°F dayExcellent · beats 97%
- Heat at 5°F
- 17,600 BTU/h51% of its 47°F outputAverage · beats 51%
A good fit if…
- You want a choice of indoor units - 109 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Lennox |
| Outdoor unit model | ML14KP1-036-230A |
| Series | MERIT ML14KP1 Series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | September 22, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.5 (range 15.2-16.5) |
| EER2Efficiency at 95°F outdoors | 12.5-13.8 |
| Cooling capacity | 35,400-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 31,400-35,600 BTU/h |
| Capacity at 17°F | 20,000-21,200 BTU/h |
| Capacity at 5°F | 15,700-17,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.06 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40[C,U]T-36C-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 109 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CK40[C,U]T-36C-**+TDR | SL280UH090XV60C* | 16.5 | 13.8 | 8.1 | 17,300 | 218073832 |
| CK40[C,U]T-36C-**+TDR | SL280UH090V60C* | 16.5 | 13.8 | 8.1 | 17,300 | 218073831 |
| CK40[C,U]T-36C-**+TDR | ML180UH110V60C* | 16.5 | 13.6 | 8.1 | 17,300 | 218073828 |
| CK40[C,U]T-36C-**+TDR | EL297UH110XV48C* | 16.5 | 13.6 | 8.0 | 17,100 | 218073839 |
| CK40[C,U]T-36C-**+TDR | ML180UH090E60C* | 16.5 | 13.6 | 8.0 | 17,100 | 218073824 |
| CK40[C,U]T-36C-**+TDR | ML196UH090XE60C* | 16.5 | 13.6 | 8.0 | 17,100 | 218073819 |
| CK40[C,U]T-36C-**+TDR | EL280UH110XE60C* | 16.5 | 13.8 | 8.0 | 17,200 | 218073818 |
| CK40[C,U]T-36C-**+TDR | EL280UH110E60C* | 16.5 | 13.8 | 8.0 | 17,200 | 218073817 |
| CK40[C,U]T-36C-**+TDR | ML193UH110XE60C* | 16.5 | 13.6 | 8.0 | 17,100 | 218073816 |
| CK40[C,U]T-36C-**+TDR | ML193UH110XE48C* | 16.5 | 13.6 | 8.0 | 17,100 | 218073815 |
| CK40[C,U]T-36C-**+TDR | EL280UH110E48C* | 16.5 | 13.8 | 8.0 | 17,000 | 218073811 |
| CK40[C,U]T-36C-**+TDR | EL196UH110XE60C* | 16.5 | 13.6 | 8.0 | 17,200 | 218073810 |
| CK40[C,U]T-36C-**+TDR | EL297UH090XV36C* | 16.5 | 13.6 | 7.8 | 17,100 | 218073842 |
| CK40[C,U]T-36C-**+TDR | EL297UH090XE48C* | 16.5 | 13.6 | 7.8 | 17,000 | 218073822 |
| CK40[C,U]T-36C-**+TDR | ML180UH110XE60C* | 16.5 | 13.6 | 7.8 | 17,000 | 218073813 |
| CK40[C,U]T-36C-**+TDR | ML180UH110E60C* | 16.5 | 13.6 | 7.8 | 17,000 | 218073812 |
| CK40[C,U]T-36C-**+TDR | ML196UH090XE48C* | 16.0 | 13.6 | 8.0 | 17,200 | 218073846 |
| CK40[C,U]T-36C-**+TDR | ML296UH090XV48C* | 16.0 | 13.4 | 8.0 | 17,300 | 218073845 |
| CK40[C,U]T-36C-**+TDR | ML296UH110XV60C* | 16.0 | 13.6 | 8.0 | 17,200 | 218073843 |
| CK40[C,U]T-36C-**+TDR | EL297UH090XV60C* | 16.0 | 13.4 | 8.0 | 17,400 | 218073840 |
| CK40[C,U]T-36C-**+TDR | EL297UH110XV60C* | 16.0 | 13.6 | 8.0 | 17,400 | 218073838 |
| CK40[C,U]T-36C-**+TDR | SLP99UH110XV60C* | 16.0 | 13.6 | 8.0 | 17,300 | 218073837 |
| CK40[C,U]T-36C-**+TDR | SLP99UH090XV48C* | 16.0 | 13.4 | 8.0 | 17,200 | 218073836 |
| CK40[C,U]T-36C-**+TDR | SLP99UH090XV36C* | 16.0 | 13.4 | 8.0 | 17,300 | 218073835 |
| CK40[C,U]T-36C-**+TDR | SLP99UH090XV60C* | 16.0 | 13.4 | 8.0 | 17,500 | 218073834 |
| CK40[C,U]T-36C-**+TDR | ML196UH090XE36C* | 16.0 | 13.4 | 8.0 | 17,300 | 218073833 |
| CK40[C,U]T-36C-**+TDR | EL196UH090XE48C* | 16.0 | 13.6 | 8.0 | 17,200 | 218073830 |
| CK40[C,U]T-36C-**+TDR | ML196UH110XE60C* | 16.0 | 13.6 | 8.0 | 17,200 | 218073829 |
| CK40[C,U]T-36C-**+TDR | SL280UH100NV60C* | 16.0 | 13.4 | 8.0 | 17,400 | 218073821 |
| CK40[C,U]T-36C-**+TDR | SL280UH080NV60C* | 16.0 | 13.6 | 8.0 | 17,300 | 218073820 |
| CK40[C,U]T-36C-**+TDR | ML193UH090XE36C* | 16.0 | 13.4 | 8.0 | 17,300 | 218073814 |
| CK40[C,U]T-36C-**+TDR | EL180UH100NE60C* | 16.0 | 13.4 | 8.0 | 17,500 | 218073809 |
| CK40[C,U]T-36C-**+TDR | EL297UH110XE60C* | 16.0 | 13.6 | 8.0 | 17,200 | 218073808 |
| CK40[C,U]T-48C-**+TDR | EL280UH110E60C* | 16.0 | 13.4 | 7.8 | 16,500 | 215735649 |
| CK40[C,U]T-48C-**+TDR | EL280UH110XE60C* | 16.0 | 13.4 | 7.8 | 16,500 | 215735650 |
| CK40HT-42C-**+TDR | EL280UH110E48C* | 16.0 | 13.2 | 7.8 | 16,400 | 215735718 |
| CK40HT-42C-**+TDR | EL280UH110E60C* | 16.0 | 13.4 | 7.8 | 16,500 | 215735719 |
| CK40HT-42C-**+TDR | EL280UH110XE60C* | 16.0 | 13.4 | 7.8 | 16,500 | 215735720 |
| CK40HT-42C-**+TDR | ML180UH090E60C* | 16.0 | 13.4 | 7.8 | 16,600 | 215735728 |
| CBK47UHET-042-230- | - | 16.0 | 13.2 | 7.8 | 16,300 | 215863846 |
| CBK48MVT-042-230- | - | 16.0 | 13.4 | 7.8 | 16,300 | 215863847 |
| CK40[C,U]T-36C-**+TDR | EL297UH090XV48C* | 16.0 | 13.4 | 7.8 | 17,200 | 218073841 |
| CK40[C,U]T-36C-**+TDR | ML193UH090XE48C* | 16.0 | 13.4 | 7.8 | 17,200 | 218073823 |
| CK40[C,U]T-36C-**+TDR | SL297UH080NV60C* | 15.5 | 13.2 | 8.0 | 17,600 | 218073844 |
| CK40[C,U]T-48C-**+TDR | EL280UH110E48C* | 15.5 | 13.4 | 7.8 | 16,500 | 215735648 |
| CK40[C,U]T-48C-**+TDR | EL296UH110XV48C* | 15.5 | 13.0 | 7.8 | 16,600 | 215735656 |
| CK40[C,U]T-48C-**+TDR | EL296UH110XV60C* | 15.5 | 13.2 | 7.8 | 16,800 | 215735657 |
| CK40[C,U]T-48C-**+TDR | EL297UH090XE48C* | 15.5 | 13.0 | 7.8 | 16,600 | 215735658 |
| CK40[C,U]T-48C-**+TDR | ML180UH090E60C* | 15.5 | 13.2 | 7.8 | 16,600 | 215735659 |
| CK40[C,U]T-48C-**+TDR | ML180UH110E60C* | 15.5 | 13.4 | 7.8 | 16,600 | 215735660 |
| CK40[C,U]T-48C-**+TDR | ML193UH110XE48C* | 15.5 | 13.2 | 7.8 | 16,600 | 215735664 |
| CK40[C,U]T-48C-**+TDR | ML180UH110V60C* | 15.5 | 13.4 | 7.8 | 16,500 | 215735661 |
| CK40[C,U]T-48C-**+TDR | SL280UH080NV60C* | 15.5 | 13.2 | 7.8 | 16,600 | 215735672 |
| CK40[C,U]T-48C-**+TDR | SL280UH090V60C* | 15.5 | 13.2 | 7.8 | 16,700 | 215735673 |
| CK40[C,U]T-48C-**+TDR | SL280UH090XV60C* | 15.5 | 13.2 | 7.8 | 16,700 | 215735674 |
| CK40[C,U]T-48C-**+TDR | SL280UH100NV60C* | 15.5 | 13.2 | 7.8 | 16,800 | 215735675 |
| CK40[C,U]T-48C-**+TDR | SLP99UH110XV60C* | 15.5 | 13.2 | 7.8 | 16,700 | 215735680 |
| CK40HT-42B-**+TDR | EL280UH090E36B* | 15.5 | 13.0 | 7.8 | 16,800 | 215735685 |
| CK40HT-42B-**+TDR | EL280UH090E48B* | 15.5 | 13.2 | 7.8 | 16,700 | 215735686 |
| CK40HT-42B-**+TDR | EL280UH090XE48B* | 15.5 | 13.2 | 7.8 | 16,700 | 215735687 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,259/yr
- Miami, FL$1,025/yr
- Houston, TX$1,128/yr
- Atlanta, GA$1,136/yr
- Los Angeles, CA$1,104/yr
- New York, NY$2,707/yr
- Chicago, IL$2,196/yr
- Denver, CO$1,825/yr
- Seattle, WA$1,120/yr
- Minneapolis, MN$2,258/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Lennox ML14KP1-036-230A?
- The Lennox ML14KP1-036-230A is rated at up to 16.5 SEER2 and 13.8 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 109 certified matchups SEER2 ranges from 15.2-16.5.
- Is the Lennox ML14KP1-036-230A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
- How much does the Lennox ML14KP1-036-230A cost to run per year?
- At its rated efficiency it costs about $1,025-$2,707 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,259 in Phoenix and $2,258 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Lennox ML14KP1-036-230A?
- ENERGY STAR lists 109 certified combinations for this outdoor unit. The highest-rated ones use CK40[C,U]T-36C-**+TDR, CK40[C,U]T-48C-**+TDR, CK40HT-42C-**+TDR.
- What refrigerant does the Lennox ML14KP1-036-230A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Innovair SHV36H2BA · cold climate16.5 SEER2 · 8.2 HSPF2
- Trane 5TWX6036A116.5 SEER2 · 8.1 HSPF2
- Trane 5TWX5036A116.5 SEER2 · 8.5 HSPF2
- Trane 5TWR6036A116.5 SEER2 · 8.5 HSPF2
- 1HVAC ACIQ-36-HPC · cold climate16.3 SEER2 · 9.5 HSPF2
- Trane 5TWR5036A116.5 SEER2 · 8.5 HSPF2
- AI AIR CONDITIONING AUO18-36N1-M3H · cold climate16.3 SEER2 · 9.5 HSPF2
- Tempstar T5H8T36*K*AAA16.5 SEER2 · 8.5 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.