9,000 BTU mini-split heat pump · MSEP Series
MDV MOX230-09HFN10-M1
Excellent cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #120 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $187 a year to run in a mixed climate like Atlanta.
- SEER2
- 26.0 Cooling efficiency over a seasonExcellent · beats 91%
- HSPF2
- 13.9 Heating efficiency over a seasonExcellent · beats 98%
- EER2
- 16.3 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 8,600 BTU/h96% of its 47°F outputExcellent · beats 90%
A good fit if…
- You want low cooling bills - its SEER2 beats 91% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 8,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 98% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Outdoor unit model | MOX230-09HFN10-M1 |
| Series | MSEP Series |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | February 4, 2024 |
| Last certified | May 6, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 26.0 (range 19.5-26.0) |
| EER2Efficiency at 95°F outdoors | 12.8-16.3 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 11.0-13.9 |
| Capacity at 47°F | 9,000-11,000 BTU/h |
| Capacity at 17°F | 7,900-9,300 BTU/h |
| Capacity at 5°F | 8,000-8,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.17-2.36 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MFA2-09HRFN10-M1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MFA2-09HRFN10-M1 · cold climate | 26.0 | 16.3 | 13.9 | 8,600 | 214855435 |
| MFA2M-12HRFN10-M1 · cold climate | 26.0 | 16.3 | 13.9 | 8,600 | 214855436 |
| MFA2-09HRFN10-M1-D · cold climate | 26.0 | 16.2 | 13.9 | 8,600 | 214855518 |
| MFA2M-12HRFN10-M1-D · cold climate | 26.0 | 16.2 | 13.9 | 8,600 | 214855519 |
| MSEPB-09HRFN10-M1 · cold climate | 26.0 | 14.9 | 12.5 | 8,000 | 214855430 |
| MSEPB-09HRFN10-M1-D · cold climate | 25.8 | 14.9 | 12.5 | 8,000 | 214855513 |
| MSEPBM-12HRFN10-M1 · cold climate | 25.8 | 14.9 | 12.5 | 8,000 | 216032444 |
| MSAB3BM-12HRFN10-M1 · cold climate | 24.6 | 14.4 | 13.0 | 8,100 | 216032441 |
| MSAG11BM-12HRFN10-M1 · cold climate | 24.6 | 14.7 | 13.0 | 8,200 | 216032442 |
| MSAB3B-09HRFN10-M1 · cold climate | 24.6 | 14.4 | 13.0 | 8,100 | 214855428 |
| MSAG11B-09HRFN10-M1 · cold climate | 24.6 | 14.7 | 13.0 | 8,200 | 214855429 |
| MCB-09HRFN10-M1 · cold climate | 22.2 | 14.4 | 11.8 | 8,000 | 214855431 |
| MCBM-12HRFN10-M1 · cold climate | 22.2 | 14.4 | 11.8 | 8,000 | 214855432 |
| MCB-09HRFN10-M1-D · cold climate | 22.1 | 14.4 | 11.8 | 8,000 | 214855514 |
| MCBM-12HRFN10-M1-D · cold climate | 22.1 | 14.4 | 11.8 | 8,000 | 214855515 |
| MCA4-09HRFN10-M1 · cold climate | 21.7 | 14.3 | 11.3 | 8,300 | 214855433 |
| MCA4M-12HRFN10-M1 · cold climate | 21.7 | 14.3 | 11.3 | 8,300 | 214855434 |
| MCA4-09HRFN10-M1-D · cold climate | 21.6 | 14.3 | 11.3 | 8,300 | 214855516 |
| MCA4M-12HRFN10-M1-D · cold climate | 21.6 | 14.3 | 11.3 | 8,300 | 214855517 |
| MTJ-09HWFN10-M1 · cold climate | 19.8 | 13.0 | 11.5 | 8,300 | 214861930 |
| MTJM-12HWFN10-M1 · cold climate | 19.8 | 13.0 | 11.5 | 8,300 | 214861931 |
| MTJ-09HWFN10-M1-D · cold climate | 19.7 | 13.0 | 11.5 | 8,300 | 214861947 |
| MTJM-12HWFN10-M1-D · cold climate | 19.7 | 13.0 | 11.5 | 8,300 | 214861948 |
| MTI-09HWFN10-M1 · cold climate | 19.6 | 12.8 | 11.0 | 8,600 | 214855437 |
| MTIM-12HWFN10-M1 · cold climate | 19.6 | 12.8 | 11.0 | 8,600 | 214861929 |
| MTI-09HWFN10-M1-D · cold climate | 19.5 | 12.8 | 11.0 | 8,600 | 214861945 |
| MTIM-12HWFN10-M1-D · cold climate | 19.5 | 12.8 | 11.0 | 8,600 | 214861946 |
Yearly running cost in 10 large cities
- Phoenix, AZ$203/yr
- Miami, FL$163/yr
- Houston, TX$182/yr
- Atlanta, GA$187/yr
- Los Angeles, CA$183/yr
- New York, NY$451/yr
- Chicago, IL$367/yr
- Denver, CO$305/yr
- Seattle, WA$188/yr
- Minneapolis, MN$378/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOX230-09HFN10-M1?
- The MDV MOX230-09HFN10-M1 is rated at up to 26.0 SEER2 and 16.3 EER2 for cooling and up to 13.9 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 27 certified matchups SEER2 ranges from 19.5-26.0.
- Is the MDV MOX230-09HFN10-M1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 8,600 BTU/h at 5°F with a COP of 2.36, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOX230-09HFN10-M1 cost to run per year?
- At its rated efficiency it costs about $163-$451 a year in electricity in large U.S. cities, depending on climate and local rates - for example $203 in Phoenix and $378 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOX230-09HFN10-M1?
- ENERGY STAR lists 27 certified combinations for this outdoor unit. The highest-rated ones use MFA2-09HRFN10-M1, MFA2M-12HRFN10-M1, MFA2-09HRFN10-M1-D.
- What refrigerant does the MDV MOX230-09HFN10-M1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- Mainline ML09HP230NEX-O · cold climate26.0 SEER2 · 13.9 HSPF2
- Midea MO1ES-H09B-2A · cold climate26.0 SEER2 · 13.9 HSPF2
- DuraSTAR DRA1U09S2A · cold climate26.0 SEER2 · 13.9 HSPF2
- NOVAIR LEA09SZ26-O · cold climate26.0 SEER2 · 13.9 HSPF2
- DIRECT AIR DIRM4-09DA25-1Z · cold climate26.0 SEER2 · 13.9 HSPF2
- ComfortStar CHF3-09CD(O) · cold climate26.0 SEER2 · 13.8 HSPF2
- Cooper&Hunter CH-RES09-230VO · cold climate26.0 SEER2 · 13.9 HSPF2
- SLIMAIR SHC09AH2AG · cold climate26.0 SEER2 · 13.8 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.