HVAC Rated

9,000 BTU mini-split heat pump · CH Series

Cooper&Hunter CH-RES09-230VO

Excellent cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #116 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $187 a year to run in a mixed climate like Atlanta.

SEER2
26.0 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
13.9 Heating efficiency over a season
Excellent · beats 98%
EER2
16.2 Cooling efficiency on a 95°F day
Excellent · beats 97%
Heat at 5°F
8,600 BTU/h96% of its 47°F output
Excellent · beats 90%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of mini-splits.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 8,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 98% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications9,000 BTU, R-454B
General
BrandCooper&Hunter
Outdoor unit modelCH-RES09-230VO
SeriesCH Series
TypeMini-split heat pump
Nominal size9,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 12, 2024
Last certifiedMay 6, 2026
Cooling
SEER2Seasonal efficiency, higher is better26.0 (range 19.5-26.0)
EER2Efficiency at 95°F outdoors12.8-16.2
Cooling capacity9,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better11.0-13.9
Capacity at 47°F9,000-11,000 BTU/h
Capacity at 17°F7,900-9,300 BTU/h
Capacity at 5°F8,000-8,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.17-2.36
ENERGY STAR cold climateYes
Heating output as it gets colder96% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CH-RSH09MMC at the standard test temperatures, in BTU/h:

Certified matchups10 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
CH-RSH09MMC · cold climate26.016.213.98,600215864235
CH-PRO09MASTWM-230VI · cold climate25.814.912.58,000215864168
CH-RH09MASTWM-230VI · cold climate25.814.912.58,000215864184
CH-R09MOLVWM-230VI · cold climate24.614.713.08,200215864147
CH-RB09MOLVWM-230VI · cold climate24.614.713.08,200215864159
CH-RSH06-12MCT1W · cold climate22.114.411.88,000215864248
CH-RSH09-12MCT · cold climate21.614.311.38,300215864194
CH-RH09MCT · cold climate21.614.311.38,300215864206
CH-RS09MDT-MS · cold climate19.512.811.08,600215864223
CH-RS06-12MDT- MS · cold climate19.512.811.08,600215864225
Yearly running cost in 10 large cities$163-$451

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Cooper&Hunter CH-RES09-230VO?
The Cooper&Hunter CH-RES09-230VO is rated at up to 26.0 SEER2 and 16.2 EER2 for cooling and up to 13.9 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 10 certified matchups SEER2 ranges from 19.5-26.0.
Is the Cooper&Hunter CH-RES09-230VO good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 8,600 BTU/h at 5°F with a COP of 2.36, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
How much does the Cooper&Hunter CH-RES09-230VO cost to run per year?
At its rated efficiency it costs about $163-$451 a year in electricity in large U.S. cities, depending on climate and local rates - for example $203 in Phoenix and $378 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Cooper&Hunter CH-RES09-230VO?
ENERGY STAR lists 10 certified combinations for this outdoor unit. The highest-rated ones use CH-RSH09MMC, CH-PRO09MASTWM-230VI, CH-RH09MASTWM-230VI.
What refrigerant does the Cooper&Hunter CH-RES09-230VO use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $202/yrYou save $278/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Cooper&Hunter CH-RES09-230VO
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$202
Current system, per year
$480
You save per year
$278
Payback
12.6 years
Net after 10 years
-$720

Cooling $122Heating $81Electricity used: 1,265 kWhSaved vs. a minimum-efficiency heat pump: $168

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 9,000 BTU models

See all 395 9,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.