9,000 BTU mini-split heat pump · ACIQ Series
ACIQ ACIQ-09ZS-HP230C
Excellent cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #112 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $187 a year to run in a mixed climate like Atlanta.
- SEER2
- 26.0 Cooling efficiency over a seasonExcellent · beats 91%
- HSPF2
- 13.9 Heating efficiency over a seasonExcellent · beats 98%
- EER2
- 16.2 Cooling efficiency on a 95°F dayExcellent · beats 97%
- Heat at 5°F
- 8,600 BTU/h96% of its 47°F outputExcellent · beats 90%
A good fit if…
- You want low cooling bills - its SEER2 beats 91% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 8,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 98% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | ACIQ |
| Also sold as | 1HVAC |
| Outdoor unit model | ACIQ-09ZS-HP230C |
| Series | ACIQ Series |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | February 10, 2025 |
| Last certified | June 9, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 26.0 (range 19.7-26.0) |
| EER2Efficiency at 95°F outdoors | 13.0-16.2 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 11.3-13.9 |
| Capacity at 47°F | 9,000-11,000 BTU/h |
| Capacity at 17°F | 7,900-9,300 BTU/h |
| Capacity at 5°F | 8,000-8,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.17-2.36 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACIQ-12FM-HH-MD at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| ACIQ-12FM-HH-MD · cold climate | 26.0 | 16.2 | 13.9 | 8,600 | 218471576 |
| ACIQ-09FM-HH-MD · cold climate | 26.0 | 16.2 | 13.9 | 8,600 | 218471575 |
| ACIQ-09W-HH-MD · cold climate | 25.8 | 14.9 | 12.5 | 8,000 | 218471572 |
| ACIQ-09WS-HP230C · cold climate | 24.6 | 14.7 | 13.0 | 8,200 | 216980867 |
| ACIQ-09WS-HP230C 1HVAC · cold climate | 24.6 | 14.7 | 13.0 | 8,200 | 216980881 |
| ACIQ-09W-BL-MD · cold climate | 24.6 | 14.7 | 13.0 | 8,200 | 218457916 |
| SCC-0612-HH-MB · cold climate | 22.1 | 14.4 | 11.8 | 8,000 | 217739018 |
| ACIQ-12CC-HH-MC · cold climate | 21.6 | 14.3 | 11.3 | 8,300 | 218471574 |
| ACIQ-09CC-HH-MC · cold climate | 21.6 | 14.3 | 11.3 | 8,300 | 218471573 |
| ACIQ-09CD-HH-MC · cold climate | 19.7 | 13.0 | 11.5 | 8,300 | 218471577 |
| ACIQ-12CD-HH-MC · cold climate | 19.7 | 13.0 | 11.5 | 8,300 | 218471578 |
Yearly running cost in 10 large cities
- Phoenix, AZ$203/yr
- Miami, FL$163/yr
- Houston, TX$182/yr
- Atlanta, GA$187/yr
- Los Angeles, CA$183/yr
- New York, NY$451/yr
- Chicago, IL$367/yr
- Denver, CO$305/yr
- Seattle, WA$188/yr
- Minneapolis, MN$378/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the ACIQ ACIQ-09ZS-HP230C?
- The ACIQ ACIQ-09ZS-HP230C is rated at up to 26.0 SEER2 and 16.2 EER2 for cooling and up to 13.9 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 11 certified matchups SEER2 ranges from 19.7-26.0.
- Is the ACIQ ACIQ-09ZS-HP230C good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 8,600 BTU/h at 5°F with a COP of 2.36, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
- How much does the ACIQ ACIQ-09ZS-HP230C cost to run per year?
- At its rated efficiency it costs about $163-$451 a year in electricity in large U.S. cities, depending on climate and local rates - for example $203 in Phoenix and $378 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the ACIQ ACIQ-09ZS-HP230C?
- ENERGY STAR lists 11 certified combinations for this outdoor unit. The highest-rated ones use ACIQ-12FM-HH-MD, ACIQ-09FM-HH-MD, ACIQ-09W-HH-MD.
- What refrigerant does the ACIQ ACIQ-09ZS-HP230C use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- AC Pro MHPC-H-009BSB · cold climate26.0 SEER2 · 13.9 HSPF2
- AI AIR CONDITIONING AO24-09N2-M1 · cold climate26.0 SEER2 · 13.9 HSPF2
- MDV MOX330-09HFN1-MY6W · cold climate26.3 SEER2 · 11.4 HSPF2
- Arcoaire D5CSRAH09AAK · cold climate26.0 SEER2 · 13.9 HSPF2
- Goodman MSH093G22MCAA · cold climate26.4 SEER2 · 11.6 HSPF2
- Carrier 37MARAQ09AA3 · cold climate26.0 SEER2 · 13.9 HSPF2
- SLIMAIR SHC09VH2AG · cold climate26.4 SEER2 · 12.0 HSPF2
- Cooper&Hunter CH-RES09-230VO · cold climate26.0 SEER2 · 13.9 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.