3.5-ton central heat pump · MVB Series
MDV MOX630-42HFN10-M3X-D
Average cooling efficiency and very good heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.
Ranks #43 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,365 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.7 Cooling efficiency over a seasonAverage · beats 43%
- HSPF2
- 9.5 Heating efficiency over a seasonVery good · beats 70%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 46,000 BTU/h92% of its 47°F outputBelow average · beats 20%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 46,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Also sold as | ACIQ, 1HVAC |
| Outdoor unit model | MOX630-42HFN10-M3X-D |
| Series | MVB Series |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 12, 2022 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.7 (range 15.7-16.7) |
| EER2Efficiency at 95°F outdoors | 10.5-11.7 |
| Cooling capacity | 42,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.8-9.5 |
| Capacity at 47°F | 48,000-50,000 BTU/h |
| Capacity at 17°F | 34,400-39,500 BTU/h |
| Capacity at 5°F | 42,000-46,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.85-1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVBC-42HWFN10-MD3E-DD at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MVBC-42HWFN10-MD3E-DD · cold climate | 16.7 | 11.7 | 9.5 | 46,000 | 214861593 |
| MVBC-48HWFN10-MD3E-DD · cold climate | 16.7 | 11.7 | 9.5 | 46,000 | 215374763 |
| MVBM-60C28T6N10 · cold climate | 15.7 | 10.5 | 8.8 | 42,000 | 218806035 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the MDV MOX630-42HFN10-M3X-D: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- ACIQ ACIQ-42-HPD
Yearly running cost in 10 large cities
- Phoenix, AZ$1,477/yr
- Miami, FL$1,184/yr
- Houston, TX$1,325/yr
- Atlanta, GA$1,365/yr
- Los Angeles, CA$1,334/yr
- New York, NY$3,293/yr
- Chicago, IL$2,679/yr
- Denver, CO$2,232/yr
- Seattle, WA$1,375/yr
- Minneapolis, MN$2,765/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOX630-42HFN10-M3X-D?
- The MDV MOX630-42HFN10-M3X-D is rated at up to 16.7 SEER2 and 11.7 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 15.7-16.7.
- Is the MDV MOX630-42HFN10-M3X-D good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 46,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOX630-42HFN10-M3X-D cost to run per year?
- At its rated efficiency it costs about $1,184-$3,293 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,477 in Phoenix and $2,765 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the MDV MOX630-42HFN10-M3X-D the same as the ACIQ ACIQ-42-HPD?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the MDV MOX630-42HFN10-M3X-D?
- ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use MVBC-42HWFN10-MD3E-DD, MVBC-48HWFN10-MD3E-DD, MVBM-60C28T6N10.
- What refrigerant does the MDV MOX630-42HFN10-M3X-D use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Mainline ML42HP230LMNTH-O · cold climate16.7 SEER2 · 9.5 HSPF2
- Midea MO1HE-H42B-2A · cold climate16.7 SEER2 · 9.5 HSPF2
- DuraSTAR DRU1H42S2A · cold climate16.7 SEER2 · 9.5 HSPF2
- DuraSTAR DRU1U48S2A · cold climate16.7 SEER2 · 9.0 HSPF2
- AI AIR CONDITIONING AUO19-42N2-M3H-S · cold climate16.7 SEER2 · 9.5 HSPF2
- Trane 5TWR5042A117.0 SEER2 · 8.5 HSPF2
- Midea MO1BE-H48B-2A · cold climate16.7 SEER2 · 9.0 HSPF2
- Samsung AC048FCUPCG · cold climate17.0 SEER2 · 8.5 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.