3.5-ton central heat pump · 15 Single-Stage Heat Pump

Trane 5TWR5042A1

Average cooling efficiency and below average heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #39 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,231 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
20,000 BTU/h49% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 293 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model5TWR5042A1
Series15 Single-Stage Heat Pump
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 25, 2024
Last certifiedJune 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity37,400-41,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F37,400-40,500 BTU/h
Capacity at 17°F24,600-26,400 BTU/h
Capacity at 5°F18,700-20,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5PX*D010AS3+TSTAT+P0V0D000M50SD at the standard test temperatures, in BTU/h:

Certified matchups293 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 293 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5PX*D010AS3+TSTAT+P0V0D000M50SD-17.012.08.119,100215569110
5TXCD010AS3+TSTATS9V2D120U5PSC16.512.08.119,000214078953
5TXCD010AS3+TSTATS9V2D120U5VSB16.512.08.118,900214078957
5TXCD010AS3+TSTAT+P0V0D000M50SD-16.512.08.118,800214078963
5PX*C009AS3+TSTAT+P0V0C000M50SD-16.512.08.119,000215574170
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.512.08.119,400215568900
5PX*C009AS3+TSTATL8V1C100U5VSB16.512.08.119,100215568962
5PX*CD09AS3+TSTATS9V2C100D4VSB16.512.08.119,700215569032
5PX*D008AS3+TSTAT+P0V0D000M50SD-16.512.08.119,200215569078
5PX*D010AS3+TSTATS8V2D120M5PDB16.512.08.119,300215569106
5PX*D010AS3+TSTATS8V2D120M5PCB16.512.08.119,300215569108
5PX*D010AS3+TSTATS9V2D120U5VSB16.512.08.119,400215569116
5PX*D010AS3+TSTATS9V2D120U5PSC16.512.08.119,400215569118
5PX*DD10AS3+TSTAT+P0V0D000M50SD-16.512.08.119,100215569124
5TXCC009AS3+TSTATL8V1C100U5VSB16.512.08.119,100215566554
5TXCD008AS3+TSTAT+P0V0D000M50SD-16.512.08.119,200215566594
5TXCC009AS3+TSTAT+P0V0C000M50SD-16.512.08.119,000215566522
5TEMCD06AV41+TDR+TSTAT-16.512.08.118,700215863946
5TEMCD07AV51+TDR+TSTAT-16.512.08.118,700215863948
5PX*CD09AS3+TSTAT+P0V0C000M50SD-16.512.08.019,100215569044
5TEM6D04AV31+TDR+TSTAT-16.012.08.519,100214078807
5TEM6D06AV41+TDR+TSTAT-16.012.08.519,400214078809
5TEM6D07AV51+TDR+TSTAT-16.012.08.519,400214078811
5TEMCD05AV41+TDR+TSTAT-16.012.08.518,900215863944
5TXCD010AS3+TSTATS8V2D120M5PCB16.012.08.119,100214078975
5TXCC007AS3+TSTATS8X2C080M5PTC16.012.08.119,300214078891
5TXCC007AS3+TSTATS8X2C100M5PSC16.012.08.119,400214078893
5TXCC007AS3+TSTATS8V2C100M5PCB16.012.08.119,400214078875
5TXCC007AS3+TSTATS8V2C100M5PDB16.012.08.119,400214078879
5TXCC007AS3+TSTATS8X1C080M5PSC16.012.08.119,300214078881
5TXCC007AS3+TSTATS8X1C080M5PTC16.012.08.119,300214078883
5TXCC007AS3+TSTATS8X1C100M5PSC16.012.08.119,400214078885
5TXCC007AS3+TSTATS8X1C100M5PTC16.012.08.119,400214078887
5TXCC007AS3+TSTATS8X2C080M5PSC16.012.08.119,300214078889
5TXCD010AS3+TSTAT*UHMD120CCV516.012.08.119,000214078967
5TXCD010AS3+TSTAT*UHMD120ACV516.012.08.119,000214078969
5TXCD010AS3+TSTATS8V2D120M5PDA16.012.08.119,100214078971
5TXCD010AS3+TSTATS8V2D120M5PCA16.012.08.119,100214078973
5TXCC007AS3+TSTATS8X2C100M5PTC16.012.08.119,400214078895
5TXCC007AS3+TSTATS9V2C080U5PSC16.012.08.119,300214078899
5TXCC007AS3+TSTATS9V2C100U4VSA16.012.08.119,300214078901
5TXCC007AS3+TSTATS9V2C100U4VSB16.012.08.119,300214078903
5TXCC007AS3+TSTATS9V2C100U5PSC16.012.08.119,200214078907
5TXCC007AS3+TSTATS8V2C080M5PDB16.012.08.119,400214078917
5TXCC007AS3+TSTATS8V2C080M5PCB16.012.08.119,400214078921
5TXCC007AS3+TSTAT+P0V0C000M50SD-16.012.08.119,100214078925
5TXCC007AS3+TSTAT+P0V0C000M50SC-16.012.08.119,100214078927
5TXCC007AS3+TSTATL8V1C100U5VSB16.012.08.119,200214078931
5TXCD010AS3+TSTATS8V2D120M5PDB16.012.08.119,100214078941
5TXCD010AS3+TSTATS8X1D120M5PSC16.012.08.119,100214078943
5TXCD010AS3+TSTATS8X1D120M5PTC16.012.08.119,100214078945
5TXCD010AS3+TSTATS8X2D120M5PSC16.012.08.119,100214078947
5TXCD010AS3+TSTATS8X2D120M5PTC16.012.08.119,100214078949
5TXCD010AS3+TSTATS9V2D120U5PSB16.012.08.118,900214078951
5TXCD010AS3+TSTATS9V2D120U5VSA16.012.08.118,900214078955
5TXCD010AS3+TSTATS9X1D120U5PSB16.012.08.118,800214078959
5TXCD010AS3+TSTATS9X2D120U5PSB16.012.08.118,800214078961
5PX*B006AS3+TSTAT+P0V0B000M40SD-16.012.08.119,600215568800
5PX*C007AS3+TSTAT*UHMC100CCV416.012.08.119,200215574168
5PX*C007AS3+TSTATS8V2C080M5PCB16.012.08.119,300215568898
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 5TWR5042A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,105-$2,939

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 5TWR5042A1?
The Trane 5TWR5042A1 is rated at up to 17.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 293 certified matchups SEER2 ranges from 15.2-17.0.
Is the Trane 5TWR5042A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the Trane 5TWR5042A1 cost to run per year?
At its rated efficiency it costs about $1,105-$2,939 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,360 in Phoenix and $2,454 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 5TWR5042A1 the same as the American Standard 5A6H5042A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 5TWR5042A1?
ENERGY STAR lists 293 certified combinations for this outdoor unit. The highest-rated ones use 5PX*D010AS3+TSTAT+P0V0D000M50SD, 5TXCD010AS3+TSTAT, 5TXCD010AS3+TSTAT+P0V0D000M50SD.
What refrigerant does the Trane 5TWR5042A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,349/yrYou save $706/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWR5042A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,349
Current system, per year
$2,054
You save per year
$706
Payback
21.3 years
Net after 10 years
-$7,944

Cooling $828Heating $520Electricity used: 8,429 kWhSaved vs. a minimum-efficiency heat pump: $226

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 16, 2026. How we use the data.