3.5-ton central heat pump · 17 Multi-Speed Heat Pump with WeatherGuard Top
Trane 5TWX7048A1
Average cooling and heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.
Ranks #32 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,309 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.1 Cooling efficiency over a seasonAverage · beats 53%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 33,200 BTU/h74% of its 47°F outputVery good · beats 80%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 33,200 BTU/h at 5°F.
- You want a choice of indoor units - 220 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Trane |
| Outdoor unit model | 5TWX7048A1 |
| Series | 17 Multi-Speed Heat Pump with WeatherGuard Top |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | January 15, 2025 |
| Last certified | June 12, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.1 (range 15.2-17.1) |
| EER2Efficiency at 95°F outdoors | 11.2-12.7 |
| Cooling capacity | 43,000-44,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-9.0 |
| Capacity at 47°F | 43,500-45,500 BTU/h |
| Capacity at 17°F | 28,800-39,500 BTU/h |
| Capacity at 5°F | 31,800-33,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.10-2.23 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5PX*C009AS3 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 220 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 5PX*C009AS3 | S9V2C080U5PSC | 17.1 | 12.0 | 9.0 | 32,000 | 216764427 |
| 5PX*D010AS3 | S9V2D120U5PSC | 17.1 | 12.0 | 9.0 | 32,000 | 216764447 |
| 5PX*D010AS3 | S9V2D120U5VSB | 17.1 | 12.0 | 9.0 | 32,000 | 216764446 |
| 5PX*D008AS3 | S8X1D120M5PSC | 17.1 | 12.0 | 9.0 | 32,800 | 216764438 |
| 5PX*D010AS3 | S9V2C080U5PSC | 17.1 | 12.0 | 9.0 | 32,000 | 216764450 |
| 5PX*D010AS3 | S8X1D120M5PSC | 17.1 | 12.0 | 9.0 | 32,400 | 216764451 |
| 5PX*D010AS3 | S8X1C100M5PSC | 17.1 | 12.0 | 9.0 | 32,200 | 216764452 |
| 5TEMCD06AV41+TDR | - | 17.1 | 12.7 | 9.0 | 31,800 | 216764460 |
| 5PX*DD10AS3 | S8X1D120M5PSC | 17.1 | 11.7 | 9.0 | 32,600 | 216764456 |
| 5TEM6D07AV51+TDR | - | 17.1 | 12.5 | 9.0 | 31,800 | 216764459 |
| 5TEMCD07AV51+TDR | - | 17.1 | 12.7 | 9.0 | 31,800 | 216764461 |
| 5TEM6D06AV41+TDR | - | 17.1 | 12.5 | 9.0 | 31,800 | 216764458 |
| 5TXCC009AS3 | S9V2C080U5PSC | 17.1 | 12.0 | 9.0 | 32,000 | 216764465 |
| 5TXCD008AS3 | S8X1D120M5PSC | 17.1 | 12.0 | 9.0 | 32,800 | 216764477 |
| 5TXCD010AS3 | S8X1C100M5PSC | 17.1 | 12.0 | 9.0 | 32,200 | 216764489 |
| 5TXCD010AS3 | S9V2D120U5VSB | 17.1 | 12.0 | 9.0 | 32,000 | 216764483 |
| 5TXCD010AS3 | S8X1D120M5PSC | 17.1 | 12.0 | 9.0 | 32,400 | 216764484 |
| 5TXCD010AS3 | S9V2D120U5PSC | 17.1 | 12.0 | 9.0 | 32,000 | 216764488 |
| 5TXCD010AS3 | S9V2C080U5PSC | 17.1 | 12.0 | 9.0 | 32,000 | 216764485 |
| 5PX*D010AS3 | S8X2C100M5PSC | 17.1 | 12.0 | 9.0 | 32,200 | 216765046 |
| 5PX*D008AS3 | S8X1D120M5PTC | 17.1 | 12.0 | 9.0 | 32,800 | 216765044 |
| 5PX*D008AS3 | S8X2D120M5PTC | 17.1 | 12.0 | 9.0 | 32,800 | 216765041 |
| 5PX*D008AS3 | S8X2D120M5PSC | 17.1 | 12.0 | 9.0 | 32,800 | 216765039 |
| 5PX*D010AS3 | S8X1C100M5PTC | 17.1 | 12.0 | 9.0 | 32,200 | 216765052 |
| 5PX*D010AS3 | S8X1D120M5PTC | 17.1 | 12.0 | 9.0 | 32,400 | 216765053 |
| 5PX*D010AS3 | S8X2D120M5PTC | 17.1 | 12.0 | 9.0 | 32,400 | 216765050 |
| 5PX*D010AS3 | S8X2D120M5PSC | 17.1 | 12.0 | 9.0 | 32,400 | 216765047 |
| 5PX*D010AS3 | S8X2C100M5PTC | 17.1 | 12.0 | 9.0 | 32,200 | 216765049 |
| 5PX*DD10AS3 | S8X2D120M5PSC | 17.1 | 11.7 | 9.0 | 32,600 | 216765055 |
| 5PX*DD10AS3 | S8X1D120M5PTC | 17.1 | 11.7 | 9.0 | 32,600 | 216765056 |
| 5PX*DD10AS3 | S8X2D120M5PTC | 17.1 | 11.7 | 9.0 | 32,600 | 216765058 |
| 5TXCD010AS3 | S8X1C100M5PTC | 17.1 | 12.0 | 9.0 | 32,200 | 216765073 |
| 5TXCD008AS3 | S8X2D120M5PTC | 17.1 | 12.0 | 9.0 | 32,800 | 216765066 |
| 5TXCD008AS3 | S8X2D120M5PSC | 17.1 | 12.0 | 9.0 | 32,800 | 216765069 |
| 5TXCD008AS3 | S8X1D120M5PTC | 17.1 | 12.0 | 9.0 | 32,800 | 216765067 |
| 5TXCD010AS3 | S8X2C100M5PSC | 17.1 | 12.0 | 9.0 | 32,200 | 216765079 |
| 5TXCD010AS3 | S8X2C100M5PTC | 17.1 | 12.0 | 9.0 | 32,200 | 216765080 |
| 5TXCD010AS3 | S8X2D120M5PSC | 17.1 | 12.0 | 9.0 | 32,400 | 216765077 |
| 5TXCD010AS3 | S8X1D120M5PTC | 17.1 | 12.0 | 9.0 | 32,400 | 216765078 |
| 5TXCD010AS3 | S8X2D120M5PTC | 17.1 | 12.0 | 9.0 | 32,400 | 216765075 |
| 5PX*C009AS3 | L8V1C100U5VSB | 17.0 | 12.0 | 9.0 | 32,000 | 216764421 |
| 5PX*C009AS3 · cold climate | S8X1C100M5PSC | 17.0 | 12.0 | 9.0 | 32,200 | 216764426 |
| 5PX*D008AS3 · cold climate | S8X1C100M5PSC | 17.0 | 11.7 | 9.0 | 33,000 | 216764437 |
| 5PX*D008AS3 | S9V2D120U5VSB | 17.0 | 12.0 | 9.0 | 32,400 | 216764441 |
| 5PX*D010AS3 | L8V1C100U5VSB | 17.0 | 12.0 | 9.0 | 32,000 | 216764442 |
| 5PX*D008AS3 | S9V2D120U5PSC | 17.0 | 12.0 | 9.0 | 32,400 | 216764439 |
| 5PX*D010AS3 | *UHMC100CCV4 | 17.0 | 12.0 | 9.0 | 32,000 | 216764444 |
| 5PX*D010AS3 | S8X1C080M5PSC | 17.0 | 12.0 | 9.0 | 32,200 | 216764453 |
| 5PX*D010AS3 · cold climate | S9V2C100U5PSC | 17.0 | 12.0 | 9.0 | 32,000 | 216764448 |
| 5PX*D010AS3 · cold climate | S9V2C100U4VSB | 17.0 | 12.0 | 9.0 | 32,000 | 216764449 |
| 5TXCC009AS3 · cold climate | S8X1C100M5PSC | 17.0 | 12.0 | 9.0 | 32,200 | 216764468 |
| 5TXCC009AS3 | L8V1C100U5VSB | 17.0 | 12.0 | 9.0 | 32,000 | 216764469 |
| 5TXCD008AS3 | S9V2D120U5PSC | 17.0 | 12.0 | 9.0 | 32,400 | 216764471 |
| 5TXCD008AS3 · cold climate | S8X1C100M5PSC | 17.0 | 11.7 | 9.0 | 33,000 | 216764476 |
| 5TXCD008AS3 | S9V2D120U5VSB | 17.0 | 12.0 | 9.0 | 32,400 | 216764472 |
| 5TXCD010AS3 | *UHMC100CCV4 | 17.0 | 12.0 | 9.0 | 32,000 | 216764478 |
| 5TXCD010AS3 | L8V1C100U5VSB | 17.0 | 12.0 | 9.0 | 32,000 | 216764480 |
| 5TXCD010AS3 | S8X1C080M5PSC | 17.0 | 12.0 | 9.0 | 32,200 | 216764482 |
| 5PX*C009AS3 · cold climate | S8X1C100M5PTC | 17.0 | 12.0 | 9.0 | 32,200 | 216765028 |
| 5PX*C009AS3 · cold climate | S8X2C100M5PSC | 17.0 | 12.0 | 9.0 | 32,200 | 216765031 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,460/yr
- Miami, FL$1,194/yr
- Houston, TX$1,308/yr
- Atlanta, GA$1,309/yr
- Los Angeles, CA$1,270/yr
- New York, NY$3,109/yr
- Chicago, IL$2,520/yr
- Denver, CO$2,093/yr
- Seattle, WA$1,284/yr
- Minneapolis, MN$2,588/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Trane 5TWX7048A1?
- The Trane 5TWX7048A1 is rated at up to 17.1 SEER2 and 12.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 220 certified matchups SEER2 ranges from 15.2-17.1.
- Is the Trane 5TWX7048A1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 33,200 BTU/h at 5°F with a COP of 2.23, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the Trane 5TWX7048A1 cost to run per year?
- At its rated efficiency it costs about $1,194-$3,109 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,460 in Phoenix and $2,588 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Trane 5TWX7048A1?
- ENERGY STAR lists 220 certified combinations for this outdoor unit. The highest-rated ones use 5PX*C009AS3, 5PX*D010AS3, 5PX*D008AS3.
- What refrigerant does the Trane 5TWX7048A1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Daikin DZ6VSA421EA · cold climate17.0 SEER2 · 8.6 HSPF2
- ECOER EODA17H-4860AD · cold climate17.5 SEER2 · 8.8 HSPF2
- Bosch BOVA-60RXB-M15S · cold climate17.0 SEER2 · 8.5 HSPF2
- Daikin DH7VSA4210A · cold climate17.5 SEER2 · 8.8 HSPF2
- Bosch BOVB-60RTB-M15S · cold climate17.0 SEER2 · 8.5 HSPF2
- MRCOOL UHP18048-O · cold climate17.5 SEER2 · 9.5 HSPF2
- Daikin DZ6VSA481EA · cold climate17.0 SEER2 · 8.5 HSPF2
- Midea MO1HE-H48B-2A · cold climate17.5 SEER2 · 9.5 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 12, 2026. How we use the data.