HVAC Rated

3.5-ton central heat pump · TDi Select 2

ECOER EODA17H-4860AD

Average cooling and heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #30 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,370 a year to run in a mixed climate like Atlanta.

SEER2
17.5 Cooling efficiency over a season
Average · beats 58%
HSPF2
8.8 Heating efficiency over a season
Average · beats 49%
EER2
11.2 Cooling efficiency on a 95°F day
Below average · beats 28%
Heat at 5°F
39,500 BTU/h71% of its 47°F output
Below average · beats 39%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 26 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3.5 ton, R-32
General
BrandECOER
Also sold asYISO
Outdoor unit modelEODA17H-4860AD
SeriesTDi Select 2
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceJuly 13, 2025
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.5 (range 15.2-17.5)
EER2Efficiency at 95°F outdoors10.0-11.7
Cooling capacity33,000-55,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-8.8
Capacity at 47°F34,200-56,000 BTU/h
Capacity at 17°F32,400-44,000 BTU/h
Capacity at 5°F30,000-39,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.85-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAHDEN-48BE at the standard test temperatures, in BTU/h:

Certified matchups26 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EAHDEN-48BE · cold climate-17.511.28.833,600218004219
EAHDEN-36BE · cold climate-17.011.78.834,200218004218
EAHDEN-60BE · cold climate-17.010.08.839,500218004220
EACE3036BE · cold climateEVMF98M28080B3L16.511.08.731,000218004224
EACE4248CE · cold climateEVMF98M35100C5L16.511.08.732,400218004225
EACE4248CE · cold climateMGV80M100C5A16.511.08.732,400218066994
EACE3036BE · cold climateMGV80M060B4A16.511.08.731,000218066993
EACE3036BE · cold climateMGV80M080B4A16.511.08.731,000218066992
EACE4248CE · cold climateMGV96U100C5C16.511.08.732,400218066986
EACE3036BE · cold climateMGV96U060B3C16.511.08.731,000218066985
EACE3036BE · cold climateMGV96U080B3C16.511.08.731,000218066984
EACE4248CE · cold climateMGH96M100C5A16.511.08.732,400218396785
EACE3036BE · cold climateMGH96M080B3A16.511.08.731,000218396784
EACE4248CE · cold climateFG7TC-080D-V35C*16.511.08.732,400218396778
EACE4248CE · cold climateFG7TC-100D-V35C*16.511.08.732,400218396777
EACE3036BE · cold climateFG7TC-060D-V24B*16.511.08.731,000218396776
EACE4860CE · cold climateEVMF98M35100C5L16.010.08.738,000218004226
EACE4860CE · cold climateMGV80M100C5A16.010.08.738,000218066995
EACE4860CE · cold climateMGV96U100C5C16.010.08.738,000218066987
EACE4860CE · cold climateMGH96M100C5A16.010.08.738,000218396787
EACE4860CE · cold climateFG7TC-100D-V35C*16.010.08.738,000218396779
EACE4248CE · cold climateMGH96M080C4A16.011.08.532,400218396786
EACE4248CE · cold climateFG7SA-090C-T35C*15.211.08.132,400218423703
EACE4248CE · cold climateFG7SA-108C-T35C*15.211.08.132,400218423702
EACE3036BE · cold climateFG7SA-072C-T24B*15.211.08.130,000218423701
EACE3036BE · cold climateFG7SA-090C-T24B*15.211.08.130,000218423700
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the ECOER EODA17H-4860AD: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,209-$3,288

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the ECOER EODA17H-4860AD?
The ECOER EODA17H-4860AD is rated at up to 17.5 SEER2 and 11.2 EER2 for cooling and up to 8.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 26 certified matchups SEER2 ranges from 15.2-17.5.
Is the ECOER EODA17H-4860AD good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,500 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the ECOER EODA17H-4860AD cost to run per year?
At its rated efficiency it costs about $1,209-$3,288 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,498 in Phoenix and $2,753 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the ECOER EODA17H-4860AD the same as the YISO YOHA3-60DD?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the ECOER EODA17H-4860AD?
ENERGY STAR lists 26 certified combinations for this outdoor unit. The highest-rated ones use EAHDEN-48BE, EAHDEN-36BE, EAHDEN-60BE.
What refrigerant does the ECOER EODA17H-4860AD use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,491/yrYou save $846/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ECOER EODA17H-4860AD
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,491
Current system, per year
$2,337
You save per year
$846
Payback
20.1 years
Net after 10 years
-$8,539

Cooling $905Heating $585Electricity used: 9,316 kWhSaved vs. a minimum-efficiency heat pump: $304

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.