HVAC Rated

3.5-ton central heat pump · TDi Pro

ECOER EODA19H-4860AA

Excellent cooling efficiency and very good heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #10 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,255 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
38,500 BTU/h81% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 38,500 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications3.5 ton, R-410A
General
BrandECOER
Also sold asYISO
Outdoor unit modelEODA19H-4860AA
SeriesTDi Pro
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceApril 10, 2024
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 15.2-19.5)
EER2Efficiency at 95°F outdoors10.8-12.5
Cooling capacity33,000-54,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.3-9.5
Capacity at 47°F35,000-55,000 BTU/h
Capacity at 17°F30,000-43,500 BTU/h
Capacity at 5°F28,000-38,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.85-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder81% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAHATN-36BA at the standard test temperatures, in BTU/h:

Certified matchups34 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EAHATN-36BA · cold climate-19.512.59.529,200214660564
EAHDEN-36AB · cold climate-19.512.59.529,200216558239
EAHATN-48BA · cold climate-19.012.59.534,400214660541
EAHDEN-48AB · cold climate-19.012.59.534,400216558240
EAHATN-60BA · cold climate-18.511.79.538,500214660542
EAHDEN-60AB · cold climate-18.511.79.538,500216558241
EAHAEC-36 · cold climate-18.212.09.529,200216019258
GNC3036BPT · cold climateMGH96M060B3A18.012.09.028,000214660558
GNC3036BPT · cold climateMGH96M080B3A18.012.09.028,000214660557
GNC3036BPT · cold climateFG7TC-060D-V24B*18.012.09.028,000215447633
SNC36CPT · cold climateFG7TC-080D-V35C*18.012.09.028,000217477693
SNC36CPT · cold climateMGH96M080C4A18.012.09.028,000217477695
GNC4248CPT · cold climateMGH96M100C5A18.011.78.832,400214660559
GNC4248CPT · cold climateFG7TC-100D-V35C*18.011.78.832,400215447634
GNC4248CPT · cold climateFG7TC-080D-V35C*18.011.78.832,400215447635
GNC4860DPT · cold climateMGH96M100D5A18.011.78.737,800214660563
GNC4860DPT · cold climateMGH96M120D5A18.011.78.737,800214660562
GNC4860CPT · cold climateMGH96M100C5A18.011.48.737,800214660561
GNC4860CPT · cold climateFG7TC-100D-V35C*18.011.48.737,800215447636
GNC4860DPT · cold climateFG7TC-120D-E45D*18.011.78.737,800215447637
GNC4248CPT · cold climateMGH96M080C4A17.511.78.832,400214660560
EAHAEC-60 · cold climate-17.011.09.238,500216019257
GNC3036BPT · cold climateFG7SA-090C-T24B*17.012.08.528,000214838775
GNC3036BPT · cold climateFG7SA-072C-T24B*17.012.08.528,000214838776
GNC4248CPT · cold climateFG7SA-108C-T35C*17.011.78.332,400214838777
GNC4248CPT · cold climateFG7SA-090C-T35C*17.011.78.332,400214838778
GNC4860CPT · cold climateFG7SA-108C-T35C*16.511.48.337,800214838779
GNC4860CPT · cold climateFG7SA-090C-T35C*16.511.28.337,800215213674
GNC4860DPT · cold climate-16.011.08.637,200216706474
GNC4860CPT · cold climate-16.011.08.637,200216706473
GNC4248CPT · cold climate-16.011.28.632,400216706472
GNC4860DPT+DK · cold climate-15.210.88.637,200214660548
GNC4860CPT+DK · cold climate-15.210.88.637,200214660547
GNC4248CPT+DK · cold climate-15.211.78.632,400214660546
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the ECOER EODA19H-4860AA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,086-$3,028

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the ECOER EODA19H-4860AA?
The ECOER EODA19H-4860AA is rated at up to 19.5 SEER2 and 12.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 34 certified matchups SEER2 ranges from 15.2-19.5.
Is the ECOER EODA19H-4860AA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 38,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the ECOER EODA19H-4860AA cost to run per year?
At its rated efficiency it costs about $1,086-$3,028 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,356 in Phoenix and $2,543 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the ECOER EODA19H-4860AA the same as the YISO YOHA2-60AA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the ECOER EODA19H-4860AA?
ENERGY STAR lists 34 certified combinations for this outdoor unit. The highest-rated ones use EAHATN-36BA, EAHDEN-36AB, EAHATN-48BA.
What refrigerant does the ECOER EODA19H-4860AA use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,355/yrYou save $982/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ECOER EODA19H-4860AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,355
Current system, per year
$2,337
You save per year
$982
Payback
17.3 years
Net after 10 years
-$7,179

Cooling $812Heating $542Electricity used: 8,466 kWhSaved vs. a minimum-efficiency heat pump: $440

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.