3.5-ton central heat pump · TDi Pro 2
ECOER EODA19H-4860AB
Very good cooling and heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.
Ranks #14 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,227 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 38,500 BTU/h72% of its 47°F outputAverage · beats 58%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 38,500 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | ECOER |
| Outdoor unit model | EODA19H-4860AB |
| Series | TDi Pro 2 |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 20, 2024 |
| Last certified | July 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 15.2-19.0) |
| EER2Efficiency at 95°F outdoors | 10.2-12.5 |
| Cooling capacity | 32,000-54,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.3-10.0 |
| Capacity at 47°F | 34,200-55,000 BTU/h |
| Capacity at 17°F | 30,000-44,500 BTU/h |
| Capacity at 5°F | 28,000-38,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAHDEN-48AB at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| EAHDEN-48AB · cold climate | - | 19.0 | 12.0 | 10.0 | 34,400 | 216445241 |
| EAHDEN-36AB · cold climate | - | 19.0 | 12.5 | 10.0 | 35,200 | 216620321 |
| EAHDEN-48ABA · cold climate | - | 19.0 | 12.0 | 10.0 | 34,400 | 218066977 |
| EAHDEN-60AB · cold climate | - | 18.5 | 11.2 | 10.0 | 38,500 | 216445242 |
| EAHDEN-60ABA · cold climate | - | 18.5 | 11.2 | 10.0 | 38,500 | 218066978 |
| EAHDEN-36BE · cold climate | - | 18.5 | 11.7 | 9.5 | 35,200 | 218004229 |
| EAHDEN-48BE · cold climate | - | 18.5 | 11.2 | 9.5 | 34,400 | 218004230 |
| EAHDEN-60BE · cold climate | - | 18.0 | 11.0 | 9.5 | 38,500 | 218004231 |
| EACT4860DBA · cold climate | MGH96M100D5A | 18.0 | 11.0 | 9.0 | 38,000 | 217477690 |
| EBCT3036BB · cold climate | MGH96M080B3A | 18.0 | 11.7 | 9.0 | 28,000 | 217596045 |
| EBCT4248CB · cold climate | MGH96M100C5A | 18.0 | 11.0 | 9.0 | 32,400 | 217596047 |
| EBCT4860DB · cold climate | MGH96M120D5A | 18.0 | 11.0 | 9.0 | 37,800 | 217596050 |
| EBCT4248CB · cold climate | FG7TC-100D-V35C* | 18.0 | 11.0 | 9.0 | 32,400 | 217596058 |
| EBCT4248CB · cold climate | FG7TC-080D-V35C* | 18.0 | 11.0 | 9.0 | 32,400 | 217596059 |
| EBCT4860CB · cold climate | FG7TC-100D-V35C* | 18.0 | 11.0 | 9.0 | 37,800 | 217596060 |
| EBCT4860DB · cold climate | FG7TC-120D-E45D* | 18.0 | 11.0 | 9.0 | 37,800 | 217596061 |
| EBCT4860CB · cold climate | MGH96M100C5A | 18.0 | 11.0 | 9.0 | 37,800 | 217596049 |
| EBCT3036BB · cold climate | MGH96M060B3A | 18.0 | 11.7 | 9.0 | 28,000 | 217596046 |
| EBCT4860DB · cold climate | MGH96M100D5A | 18.0 | 11.0 | 9.0 | 38,000 | 217596051 |
| EBCT3036BB · cold climate | FG7TC-060D-V24B* | 18.0 | 11.7 | 9.0 | 28,000 | 217596057 |
| EBCT4860CB · cold climate | EVMF98M35100C5L | 18.0 | 11.0 | 9.0 | 37,800 | 217998292 |
| EBCT4248CB · cold climate | EVMF98M35100C5L | 18.0 | 11.0 | 9.0 | 32,400 | 217998291 |
| EBCT3036BB · cold climate | EVMF98M28080B3L | 18.0 | 11.7 | 9.0 | 28,000 | 217998290 |
| EBCT3036BB · cold climate | MGV96U080B3C | 18.0 | 11.7 | 8.8 | 28,000 | 217989905 |
| EBCT3036BB · cold climate | MGV96U060B3C | 18.0 | 11.7 | 8.8 | 28,000 | 217989906 |
| EACT4860DBB | MGH96M100D5A | 18.0 | 11.0 | 8.7 | 36,000 | 217902906 |
| EBCT4248CB · cold climate | MGH96M080C4A | 17.5 | 11.0 | 9.0 | 32,400 | 217596048 |
| EACE3036BE · cold climate | EVMF98M28080B3L | 17.5 | 11.7 | 9.0 | 32,000 | 218004235 |
| EACE4248CE · cold climate | EVMF98M35100C5L | 17.5 | 11.0 | 9.0 | 32,400 | 218004236 |
| EACE4860CE · cold climate | EVMF98M35100C5L | 17.5 | 11.0 | 9.0 | 37,800 | 218004237 |
| EACE4860CE · cold climate | MGV80M100C5A | 17.5 | 11.0 | 9.0 | 37,800 | 218066975 |
| EACE4248CE · cold climate | MGV80M100C5A | 17.5 | 11.0 | 9.0 | 32,400 | 218066974 |
| EACE3036BE · cold climate | MGV80M060B4A | 17.5 | 11.7 | 9.0 | 32,000 | 218066973 |
| EACE3036BE · cold climate | MGV80M080B4A | 17.5 | 11.7 | 9.0 | 32,000 | 218066972 |
| EACE4860CE · cold climate | MGV96U100C5C | 17.5 | 11.0 | 9.0 | 37,800 | 218066967 |
| EACE4248CE · cold climate | MGV96U100C5C | 17.5 | 11.0 | 9.0 | 32,400 | 218066966 |
| EACE3036BE · cold climate | MGV96U060B3C | 17.5 | 11.7 | 9.0 | 32,000 | 218066965 |
| EACE3036BE · cold climate | MGV96U080B3C | 17.5 | 11.7 | 9.0 | 32,000 | 218066964 |
| EBCT4860CB · cold climate | MGV96U100C5C | 17.5 | 11.0 | 8.8 | 37,800 | 217989909 |
| EBCT4248CB · cold climate | MGV96U100C5C | 17.5 | 11.0 | 8.6 | 32,400 | 217989907 |
| EBCT4248CB · cold climate | MGV96U080C4C | 17.5 | 11.0 | 8.6 | 31,800 | 217989908 |
| EBCT3036BB · cold climate | MGV80M080B4A | 17.0 | 11.7 | 8.6 | 28,000 | 217989914 |
| EBCT3036BB · cold climate | MGV80M060B4A | 17.0 | 11.7 | 8.6 | 28,000 | 217989915 |
| EBCT4248CB · cold climate | MGV80M100C5A | 17.0 | 11.0 | 8.5 | 32,400 | 217989916 |
| EBCT4860CB · cold climate | MGV80M100C5A | 17.0 | 11.0 | 8.5 | 37,800 | 217989917 |
| EBCT3036BB · cold climate | FG7SA-072C-T24B* | 16.5 | 11.7 | 8.5 | 28,000 | 217596070 |
| EBCT3036BB · cold climate | FG7SA-090C-T24B* | 16.5 | 11.7 | 8.5 | 28,000 | 217596069 |
| EBCT4248CB · cold climate | FG7SA-108C-T35C* | 16.5 | 11.0 | 8.3 | 32,400 | 217596071 |
| EBCT4248CB · cold climate | FG7SA-090C-T35C* | 16.5 | 11.0 | 8.3 | 32,400 | 217596072 |
| EBCT4860CB · cold climate | FG7SA-108C-T35C* | 16.2 | 11.0 | 8.3 | 37,800 | 217596073 |
| EBCT4860CB · cold climate | FG7SA-090C-T35C* | 16.2 | 11.0 | 8.3 | 37,800 | 217596074 |
| EACT4860DBA · cold climate | - | 16.0 | 11.0 | 9.0 | 37,200 | 217477689 |
| EBCT4248CB · cold climate | - | 16.0 | 11.2 | 9.0 | 32,400 | 217596034 |
| EBCT4860CB · cold climate | - | 16.0 | 11.0 | 9.0 | 37,200 | 217596035 |
| EBCT4860DB · cold climate | - | 16.0 | 11.0 | 9.0 | 37,200 | 217596036 |
| EBCT3036BB · cold climate | - | 16.0 | 11.5 | 9.0 | 28,000 | 218066976 |
| EACE4860CE · cold climate | - | 15.2 | 10.2 | 8.8 | 37,600 | 218004247 |
| EACE4248CE · cold climate | - | 15.2 | 11.0 | 8.8 | 32,400 | 218004246 |
| EACE3036BE · cold climate | - | 15.2 | 11.5 | 8.8 | 28,000 | 218004245 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,363/yr
- Miami, FL$1,112/yr
- Houston, TX$1,222/yr
- Atlanta, GA$1,227/yr
- Los Angeles, CA$1,191/yr
- New York, NY$2,919/yr
- Chicago, IL$2,368/yr
- Denver, CO$1,967/yr
- Seattle, WA$1,207/yr
- Minneapolis, MN$2,433/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the ECOER EODA19H-4860AB?
- The ECOER EODA19H-4860AB is rated at up to 19.0 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 59 certified matchups SEER2 ranges from 15.2-19.0.
- Is the ECOER EODA19H-4860AB good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 38,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the ECOER EODA19H-4860AB cost to run per year?
- At its rated efficiency it costs about $1,112-$2,919 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,363 in Phoenix and $2,433 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the ECOER EODA19H-4860AB?
- ENERGY STAR lists 59 certified combinations for this outdoor unit. The highest-rated ones use EAHDEN-48AB, EAHDEN-36AB, EAHDEN-48ABA.
- What refrigerant does the ECOER EODA19H-4860AB use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Bosch BOVB-60MTB-M19E · cold climate19.0 SEER2 · 10.0 HSPF2
- Friedrich RD18AY48AJVC · cold climate19.0 SEER2 · 10.0 HSPF2
- Bosch BOVA-60MTB-M19E · cold climate19.0 SEER2 · 10.0 HSPF2
- YISO YOHA2-60CB · cold climate19.0 SEER2 · 10.0 HSPF2
- York YZV48B2119.5 SEER2 · 8.5 HSPF2
- LG KUSXA422A · cold climate19.0 SEER2 · 9.8 HSPF2
- York HH860E2S11 · cold climate19.0 SEER2 · 9.5 HSPF2
- Lennox SL22KLV-048-230A · cold climate20.5 SEER2 · 9.8 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.