3.5-ton central heat pump · DAVE LENNOX SIGNATURE SL22KLV SERIES
Lennox SL22KLV-048-230A
Excellent cooling efficiency and very good heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.
Ranks #9 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,191 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.5 Cooling efficiency over a seasonExcellent · beats 96%
- HSPF2
- 9.8 Heating efficiency over a seasonVery good · beats 79%
- EER2
- 12.4 Cooling efficiency on a 95°F dayVery good · beats 76%
- Heat at 5°F
- 46,500 BTU/h98% of its 47°F outputAverage · beats 58%
A good fit if…
- You want low cooling bills - its SEER2 beats 96% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 46,500 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 79% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Lennox |
| Outdoor unit model | SL22KLV-048-230A |
| Series | DAVE LENNOX SIGNATURE SL22KLV SERIES |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 14, 2024 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.5 (range 18.0-20.5) |
| EER2Efficiency at 95°F outdoors | 11.2-12.4 |
| Cooling capacity | 43,500-46,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-9.8 |
| Capacity at 47°F | 43,000-46,500 BTU/h |
| Capacity at 17°F | 37,400-46,000 BTU/h |
| Capacity at 5°F | 37,000-46,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.68-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40[C,U]T-60C-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CK40[C,U]T-60C-**+TDR · cold climate | SL280UH080NV60C* | 20.5 | 12.4 | 9.4 | 44,000 | 216776088 |
| CK40[C,U]T-60C-**+TDR · cold climate | SL280UH100NV60C* | 20.5 | 12.4 | 9.4 | 44,000 | 216776091 |
| CK40[C,U]T-49C-**+TDR · cold climate | SL280UH080NV60C* | 20.5 | 12.0 | 8.5 | 45,500 | 216776099 |
| CBK48MVT-060-230- · cold climate | - | 20.0 | 11.7 | 9.8 | 44,500 | 216776012 |
| CK40[C,U]T-60C-**+TDR · cold climate | SL280UH090V60C* | 20.0 | 12.2 | 9.4 | 44,000 | 216776089 |
| CK40[C,U]T-60C-**+TDR · cold climate | SL280UH090XV60C* | 20.0 | 12.2 | 9.4 | 44,000 | 216776090 |
| CK40[C,U]T-60C-**+TDR · cold climate | SL280UH110V60C* | 20.0 | 12.0 | 9.0 | 44,500 | 216776092 |
| CK40[C,U]T-60C-**+TDR · cold climate | SL280UH110XV60C* | 20.0 | 12.0 | 9.0 | 44,500 | 216776093 |
| CK40[C,U]T-60C-**+TDR · cold climate | SLP99UH090XV60C* | 20.0 | 11.7 | 9.0 | 44,500 | 216776095 |
| CK40[C,U]T-60C-**+TDR · cold climate | SLP99UH110XV60C* | 20.0 | 11.7 | 9.0 | 44,500 | 216776096 |
| CK40[C,U]T-60C-**+TDR · cold climate | EL297UH090XV60C* | 20.0 | 11.7 | 9.0 | 44,500 | 216776097 |
| CK40[C,U]T-60C-**+TDR · cold climate | EL297UH110XV60C* | 20.0 | 11.7 | 9.0 | 44,500 | 216776098 |
| CBK48MVT-048-230- · cold climate | - | 20.0 | 12.0 | 8.5 | 43,500 | 216776087 |
| CK40[C,U]T-60C-**+TDR · cold climate | SL297UH080NV60C* | 20.0 | 11.7 | 8.5 | 37,400 | 216776094 |
| CK40[C,U]T-49C-**+TDR · cold climate | SL280UH100NV60C* | 20.0 | 12.0 | 8.5 | 45,500 | 216776102 |
| CK40[C,U]T-49C-**+TDR | EL297UH090XV48C* | 20.0 | 11.5 | 8.1 | 38,000 | 217550310 |
| CK40[C,U]T-49C-**+TDR · cold climate | SL280UH090V60C* | 19.5 | 11.7 | 8.5 | 46,000 | 216776100 |
| CK40[C,U]T-49C-**+TDR · cold climate | SL280UH090XV60C* | 19.5 | 11.7 | 8.5 | 46,000 | 216776101 |
| CK40[C,U]T-49C-**+TDR · cold climate | SL280UH110V60C* | 19.5 | 11.7 | 8.5 | 46,000 | 216776103 |
| CK40[C,U]T-49C-**+TDR · cold climate | SL280UH110XV60C* | 19.5 | 11.7 | 8.5 | 46,000 | 216776104 |
| CK40[C,U]T-49C-**+TDR · cold climate | SLP99UH090XV60C* | 19.5 | 11.5 | 8.5 | 46,500 | 216776116 |
| CK40[C,U]T-49C-**+TDR · cold climate | SLP99UH110XV60C* | 19.5 | 11.5 | 8.5 | 46,000 | 216776117 |
| CK40[C,U]T-49C-**+TDR · cold climate | EL297UH090XV60C* | 19.5 | 11.5 | 8.5 | 46,500 | 216776118 |
| CK40[C,U]T-49C-**+TDR · cold climate | EL297UH110XV60C* | 19.5 | 11.5 | 8.5 | 46,000 | 216776119 |
| CK40[C,U]T-49C-**+TDR | SL297UH080NV60C* | 19.5 | 11.5 | 8.2 | 38,500 | 216776115 |
| CK40[C,U]T-60D-**+TDR | SL280UH135V60D* | 19.5 | 11.5 | 8.0 | 37,400 | 217476466 |
| CK40[C,U]T-60D-**+TDR | EL297UH135XV60D* | 19.5 | 11.5 | 8.0 | 37,600 | 217476470 |
| CK40[C,U]T-60D-**+TDR | SLP99UH135XV60D* | 19.5 | 11.5 | 7.8 | 37,600 | 217476468 |
| CK40HT-60D-**+TDR · cold climate | SL280UH135V60D* | 19.0 | 12.2 | 8.5 | 37,000 | 217476521 |
| CK40HT-60D-**+TDR · cold climate | SLP99UH135XV60D* | 19.0 | 12.2 | 8.5 | 37,200 | 217476522 |
| CK40HT-60D-**+TDR · cold climate | SL280UH080NV60C* | 19.0 | 12.0 | 8.5 | 37,400 | 217476523 |
| CK40HT-60D-**+TDR · cold climate | EL297UH110XV60C* | 19.0 | 12.0 | 8.5 | 37,400 | 217476525 |
| CK40HT-60D-**+TDR · cold climate | EL297UH135XV60D* | 19.0 | 12.2 | 8.5 | 37,200 | 217476526 |
| CK40HT-60D-**+TDR · cold climate | SL280UH090V60C* | 19.0 | 12.2 | 8.5 | 37,200 | 217476527 |
| CK40[C,U]T-60D-**+TDR | EL297UH110XV60C* | 19.0 | 11.5 | 7.8 | 37,600 | 217476469 |
| CK40HT-60D-**+TDR · cold climate | SLP99UH090XV60C* | 18.5 | 12.0 | 8.5 | 37,400 | 217476524 |
| CK40[C,U]T-60D-**+TDR | SL297UH080NV60C* | 18.5 | 11.2 | 7.8 | 38,000 | 217476467 |
| CK40HT-60D-**+TDR · cold climate | SL297UH080NV60C* | 18.0 | 11.7 | 8.5 | 37,600 | 217476465 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,289/yr
- Miami, FL$1,033/yr
- Houston, TX$1,156/yr
- Atlanta, GA$1,191/yr
- Los Angeles, CA$1,164/yr
- New York, NY$2,873/yr
- Chicago, IL$2,338/yr
- Denver, CO$1,948/yr
- Seattle, WA$1,200/yr
- Minneapolis, MN$2,412/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Lennox SL22KLV-048-230A?
- The Lennox SL22KLV-048-230A is rated at up to 20.5 SEER2 and 12.4 EER2 for cooling and up to 9.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 38 certified matchups SEER2 ranges from 18.0-20.5.
- Is the Lennox SL22KLV-048-230A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 46,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Lennox SL22KLV-048-230A cost to run per year?
- At its rated efficiency it costs about $1,033-$2,873 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,289 in Phoenix and $2,412 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Lennox SL22KLV-048-230A?
- ENERGY STAR lists 38 certified combinations for this outdoor unit. The highest-rated ones use CK40[C,U]T-60C-**+TDR, CK40[C,U]T-49C-**+TDR, CBK48MVT-060-230-.
- What refrigerant does the Lennox SL22KLV-048-230A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Trane 5TWV0X48A1 · cold climate20.8 SEER2 · 10.0 HSPF2
- ECOER EODA19H-4860AA · cold climate19.5 SEER2 · 9.5 HSPF2
- Carrier 25VNA448A*031 · cold climate21.0 SEER2 · 9.0 HSPF2
- York YZV48B2119.5 SEER2 · 8.5 HSPF2
- Tempstar T5H3V48*K*AAA · cold climate23.0 SEER2 · 9.5 HSPF2
- Bosch BOVA-60MTB-M19E · cold climate19.0 SEER2 · 10.0 HSPF2
- Tempstar B5H3V48*K*AAA · cold climate23.0 SEER2 · 9.5 HSPF2
- Bosch BOVB-60MTB-M19E · cold climate19.0 SEER2 · 10.0 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.