HVAC Rated

3.5-ton central heat pump · DAVE LENNOX SIGNATURE SL22KLV SERIES

Lennox SL22KLV-048-230A

Excellent cooling efficiency and very good heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #9 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,191 a year to run in a mixed climate like Atlanta.

SEER2
20.5 Cooling efficiency over a season
Excellent · beats 96%
HSPF2
9.8 Heating efficiency over a season
Very good · beats 79%
EER2
12.4 Cooling efficiency on a 95°F day
Very good · beats 76%
Heat at 5°F
46,500 BTU/h98% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 96% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 46,500 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 79% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandLennox
Outdoor unit modelSL22KLV-048-230A
SeriesDAVE LENNOX SIGNATURE SL22KLV SERIES
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 14, 2024
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better20.5 (range 18.0-20.5)
EER2Efficiency at 95°F outdoors11.2-12.4
Cooling capacity43,500-46,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-9.8
Capacity at 47°F43,000-46,500 BTU/h
Capacity at 17°F37,400-46,000 BTU/h
Capacity at 5°F37,000-46,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.68-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder98% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40[C,U]T-60C-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups38 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CK40[C,U]T-60C-**+TDR · cold climateSL280UH080NV60C*20.512.49.444,000216776088
CK40[C,U]T-60C-**+TDR · cold climateSL280UH100NV60C*20.512.49.444,000216776091
CK40[C,U]T-49C-**+TDR · cold climateSL280UH080NV60C*20.512.08.545,500216776099
CBK48MVT-060-230- · cold climate-20.011.79.844,500216776012
CK40[C,U]T-60C-**+TDR · cold climateSL280UH090V60C*20.012.29.444,000216776089
CK40[C,U]T-60C-**+TDR · cold climateSL280UH090XV60C*20.012.29.444,000216776090
CK40[C,U]T-60C-**+TDR · cold climateSL280UH110V60C*20.012.09.044,500216776092
CK40[C,U]T-60C-**+TDR · cold climateSL280UH110XV60C*20.012.09.044,500216776093
CK40[C,U]T-60C-**+TDR · cold climateSLP99UH090XV60C*20.011.79.044,500216776095
CK40[C,U]T-60C-**+TDR · cold climateSLP99UH110XV60C*20.011.79.044,500216776096
CK40[C,U]T-60C-**+TDR · cold climateEL297UH090XV60C*20.011.79.044,500216776097
CK40[C,U]T-60C-**+TDR · cold climateEL297UH110XV60C*20.011.79.044,500216776098
CBK48MVT-048-230- · cold climate-20.012.08.543,500216776087
CK40[C,U]T-60C-**+TDR · cold climateSL297UH080NV60C*20.011.78.537,400216776094
CK40[C,U]T-49C-**+TDR · cold climateSL280UH100NV60C*20.012.08.545,500216776102
CK40[C,U]T-49C-**+TDREL297UH090XV48C*20.011.58.138,000217550310
CK40[C,U]T-49C-**+TDR · cold climateSL280UH090V60C*19.511.78.546,000216776100
CK40[C,U]T-49C-**+TDR · cold climateSL280UH090XV60C*19.511.78.546,000216776101
CK40[C,U]T-49C-**+TDR · cold climateSL280UH110V60C*19.511.78.546,000216776103
CK40[C,U]T-49C-**+TDR · cold climateSL280UH110XV60C*19.511.78.546,000216776104
CK40[C,U]T-49C-**+TDR · cold climateSLP99UH090XV60C*19.511.58.546,500216776116
CK40[C,U]T-49C-**+TDR · cold climateSLP99UH110XV60C*19.511.58.546,000216776117
CK40[C,U]T-49C-**+TDR · cold climateEL297UH090XV60C*19.511.58.546,500216776118
CK40[C,U]T-49C-**+TDR · cold climateEL297UH110XV60C*19.511.58.546,000216776119
CK40[C,U]T-49C-**+TDRSL297UH080NV60C*19.511.58.238,500216776115
CK40[C,U]T-60D-**+TDRSL280UH135V60D*19.511.58.037,400217476466
CK40[C,U]T-60D-**+TDREL297UH135XV60D*19.511.58.037,600217476470
CK40[C,U]T-60D-**+TDRSLP99UH135XV60D*19.511.57.837,600217476468
CK40HT-60D-**+TDR · cold climateSL280UH135V60D*19.012.28.537,000217476521
CK40HT-60D-**+TDR · cold climateSLP99UH135XV60D*19.012.28.537,200217476522
CK40HT-60D-**+TDR · cold climateSL280UH080NV60C*19.012.08.537,400217476523
CK40HT-60D-**+TDR · cold climateEL297UH110XV60C*19.012.08.537,400217476525
CK40HT-60D-**+TDR · cold climateEL297UH135XV60D*19.012.28.537,200217476526
CK40HT-60D-**+TDR · cold climateSL280UH090V60C*19.012.28.537,200217476527
CK40[C,U]T-60D-**+TDREL297UH110XV60C*19.011.57.837,600217476469
CK40HT-60D-**+TDR · cold climateSLP99UH090XV60C*18.512.08.537,400217476524
CK40[C,U]T-60D-**+TDRSL297UH080NV60C*18.511.27.838,000217476467
CK40HT-60D-**+TDR · cold climateSL297UH080NV60C*18.011.78.537,600217476465
Yearly running cost in 10 large cities$1,033-$2,873

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox SL22KLV-048-230A?
The Lennox SL22KLV-048-230A is rated at up to 20.5 SEER2 and 12.4 EER2 for cooling and up to 9.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 38 certified matchups SEER2 ranges from 18.0-20.5.
Is the Lennox SL22KLV-048-230A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 46,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Lennox SL22KLV-048-230A cost to run per year?
At its rated efficiency it costs about $1,033-$2,873 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,289 in Phoenix and $2,412 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox SL22KLV-048-230A?
ENERGY STAR lists 38 certified combinations for this outdoor unit. The highest-rated ones use CK40[C,U]T-60C-**+TDR, CK40[C,U]T-49C-**+TDR, CBK48MVT-060-230-.
What refrigerant does the Lennox SL22KLV-048-230A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,287/yrYou save $1,033/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox SL22KLV-048-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,287
Current system, per year
$2,320
You save per year
$1,033
Payback
16.5 years
Net after 10 years
-$6,667

Cooling $773Heating $514Electricity used: 8,044 kWhSaved vs. a minimum-efficiency heat pump: $493

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.