HVAC Rated

3.5-ton central heat pump · Elite EL18KSLV Series

Lennox EL18KSLV-060-230A

Very good cooling and heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #23 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,311 a year to run in a mixed climate like Atlanta.

SEER2
18.3 Cooling efficiency over a season
Very good · beats 74%
HSPF2
9.6 Heating efficiency over a season
Very good · beats 76%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
45,000 BTU/h82% of its 47°F output
Below average · beats 27%

A good fit if…

  • You want low cooling bills - its SEER2 beats 74% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 45,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 76% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandLennox
Outdoor unit modelEL18KSLV-060-230A
SeriesElite EL18KSLV Series
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 29, 2024
Last certifiedSeptember 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.3 (range 15.2-18.3)
EER2Efficiency at 95°F outdoors9.6-11.7
Cooling capacity42,500-55,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.6
Capacity at 47°F47,000-56,500 BTU/h
Capacity at 17°F38,000-45,000 BTU/h
Capacity at 5°F39,000-45,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.95
ENERGY STAR cold climateYes
Heating output as it gets colder82% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40[C,U]T-49C-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups353 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 353 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CK40[C,U]T-49C-**+TDR · cold climateEL297UH090XV48C*18.311.09.039,000217449976
CBK45UHVT-048-230- · cold climate-18.011.79.542,000216581390
CBK48MVT-042-230- · cold climate-18.011.09.542,500216618918
CBK47UHET-048-230- · cold climate-18.010.59.543,000216705374
CBK43UHET-042-DV- · cold climate-17.910.79.645,000218636323
CBK43UHET-048-DV- · cold climate-17.910.89.444,500218636324
CK40HT-42C-**+TDR · cold climateEL297UH090XV48C*17.810.09.039,500217450000
CK40[C,U]T-48C-**+TDR · cold climateEL297UH090XV48C*17.810.09.039,500217449958
CK40[C,U]T-49C-**+TDR · cold climateSL280UH090XV60C*17.711.09.039,000217449982
CK40[C,U]T-49C-**+TDR · cold climateSL280UH090V60C*17.711.09.039,000217449981
CK40[C,U]T-49C-**+TDR · cold climateSL280UH110V60C*17.711.09.039,000217189910
CK40[C,U]T-49C-**+TDR · cold climateSL280UH110XV60C*17.711.09.039,000217449983
CBK45UHVT-042-230- · cold climate-17.611.09.043,000216618916
CBK45UHET-042-230- · cold climate-17.610.59.043,000216618915
CK40HT-42B-**+TDR · cold climateML180UH070V48B*17.610.09.439,000217449994
CK40[C,U]T-49C-**+TDR · cold climateML193UH110XE48C*17.611.09.039,000217449979
CBK47UHET-042-230- · cold climate-17.511.09.442,500216705373
CBK45UHET-048-230- · cold climate-17.511.09.043,000216618917
CBK48MVT-048-230- · cold climate-17.510.59.043,000216618919
CK40[C,U]T-49C-**+TDR · cold climateML180UH110V60C*17.511.09.039,000217449985
CK40[C,U]T-49C-**+TDR · cold climateSL280UH080NV60C*17.511.09.039,000217189911
CK40[C,U]T-49C-**+TDR · cold climateSL280UH100NV60C*17.511.09.039,000217189912
CK40HT-48B-**+TDR · cold climateML180UH070V48B*17.510.09.039,500217450018
CK40[C,U]T-48B-**+TDR · cold climateML180UH070V48B*17.510.09.039,500217449952
CK40[C,U]T-49C-**+TDR · cold climateSLP99UH110XV60C*17.411.09.039,000217189918
CK40[C,U]T-60C-**+TDR · cold climateEL297UH090XV48C*17.410.48.841,000218672220
CK40[C,U]T-49C-**+TDR · cold climateEL297UH110XV48C*17.411.09.039,500217449977
CK40[C,U]T-49C-**+TDR · cold climateEL196UH090XE48C*17.411.09.039,500217449974
CK40[C,U]T-60C-**+TDR · cold climateML180UH110V60C*17.410.08.540,000217450065
CK40[C,U]T-49C-**+TDR · cold climateML193UH090XE48C*17.311.09.039,500217449978
CK40[C,U]T-49C-**+TDR · cold climateSL297UH080NV60C*17.311.09.039,500216769605
CK40DT-48C-**+TDR · cold climateML196DF090XE48C*17.310.09.039,000217189953
CK40DT-48C-**+TDR · cold climateML193DF090XE48C*17.310.09.039,000217450043
CK40[C,U]T-49C-**+TDR · cold climateEL297UH110XV60C*17.210.09.039,500216769606
CK40[C,U]T-49C-**+TDR · cold climateML180UH110E60C*17.210.09.039,500217189917
CK40[C,U]T-49C-**+TDR · cold climateML180UH090E60C*17.211.09.039,500217189916
CK40[C,U]T-49C-**+TDR · cold climateML180UH110XE60C*17.210.09.039,500217449984
CK40[C,U]T-49C-**+TDR · cold climateEL297UH090XE48C*17.211.09.039,000217449975
CK40[C,U]T-49C-**+TDR · cold climateML297UH110XV60C*17.210.09.039,500218730769
CK40DT-48C-**+TDR · cold climateML180DF110E60C*17.211.09.039,000217189954
CK40DT-48C-**+TDR · cold climateSL280DF110V60C*17.210.09.039,500217450045
CK40[C,U]T-49C-**+TDR · cold climateML296UH110XV60C*17.210.09.039,500217449990
CK40HT-48C-**+TDR · cold climateEL297UH090XV48C*17.210.09.039,500217450024
CK40[C,U]T-60C-**+TDR · cold climateML180UH090E60C*17.210.08.540,500217189962
CK40[C,U]T-60C-**+TDR · cold climateML180UH110E60C*17.210.08.540,500217189963
CK40[C,U]T-60C-**+TDR · cold climateML180UH110XE60C*17.210.08.540,500217450064
CK40[C,U]T-49C-**+TDR · cold climateEL297UH090XV60C*17.110.09.039,500216769607
CK40DT-48C-**+TDR · cold climateSLP99DF090XV48C*17.110.09.039,500217189952
CK40[C,U]T-49C-**+TDR · cold climateSLP99UH090XV60C*17.110.09.039,500217189919
CK40DT-48C-**+TDR · cold climateEL297DF090XE48C*17.110.09.039,000217450042
CK40[C,U]T-49C-**+TDR · cold climateML297UH090XV60C*17.110.09.039,500218730770
CK40[C,U]T-48C-**+TDR · cold climateSL280UH110V60C*17.110.08.539,500217189897
CK40[C,U]T-48C-**+TDR · cold climateSL280UH090XV60C*17.110.08.539,500217449964
CK40[C,U]T-48C-**+TDR · cold climateSL280UH110XV60C*17.110.08.539,500217449965
CK40[C,U]T-60C-**+TDR · cold climateSL280UH090V60C*17.110.08.540,000217450061
CK40[C,U]T-60C-**+TDR · cold climateSL280UH090XV60C*17.110.08.540,000217450062
CK40[C,U]T-48C-**+TDR · cold climateSL280UH090V60C*17.110.08.539,500217449963
CK40[C,U]T-49C-**+TDR · cold climateEL195UH080NE48C*17.111.09.039,500217189908
CK40DT-48C-**+TDR · cold climateSL280DF090V60C*17.110.09.039,500217450044
CK40DT-60D-**+TDR · cold climateML180DF110E60C*17.110.08.540,000217189982
Yearly running cost in 10 large cities$1,156-$3,145

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox EL18KSLV-060-230A?
The Lennox EL18KSLV-060-230A is rated at up to 18.3 SEER2 and 11.0 EER2 for cooling and up to 9.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 353 certified matchups SEER2 ranges from 15.2-18.3.
Is the Lennox EL18KSLV-060-230A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 45,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Lennox EL18KSLV-060-230A cost to run per year?
At its rated efficiency it costs about $1,156-$3,145 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,433 in Phoenix and $2,633 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox EL18KSLV-060-230A?
ENERGY STAR lists 353 certified combinations for this outdoor unit. The highest-rated ones use CK40[C,U]T-49C-**+TDR, CBK45UHVT-048-230-, CBK48MVT-042-230-.
What refrigerant does the Lennox EL18KSLV-060-230A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,426/yrYou save $944/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox EL18KSLV-060-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,426
Current system, per year
$2,369
You save per year
$944
Payback
18.0 years
Net after 10 years
-$7,562

Cooling $866Heating $560Electricity used: 8,910 kWhSaved vs. a minimum-efficiency heat pump: $399

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 3, 2026. How we use the data.