HVAC Rated

4-ton central heat pump · SAV Series

Innovair SHV48H2BA

Average cooling efficiency and very good heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #136 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,375 a year to run in a mixed climate like Atlanta.

SEER2
17.5 Cooling efficiency over a season
Average · beats 58%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
48,000 BTU/h100% of its 47°F output
Below average · beats 39%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 48,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandInnovair
Also sold asNOVAIR
Outdoor unit modelSHV48H2BA
SeriesSAV Series
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceDecember 18, 2019
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.5 (range 15.2-17.5)
EER2Efficiency at 95°F outdoors9.8-12.0
Cooling capacity45,000-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.5
Capacity at 47°F46,000-50,000 BTU/h
Capacity at 17°F33,000-39,500 BTU/h
Capacity at 5°F41,000-48,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with SAV48BDU at the standard test temperatures, in BTU/h:

Certified matchups4 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
SAV48BDU · cold climate-17.512.09.548,000217966393
SAV48BDA · cold climate-16.510.59.546,000215408665
MMC60H2128B · cold climate-15.210.08.842,000216684126
MMC60H2128B · cold climateC120-M-V15.29.88.541,000217618135
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Innovair SHV48H2BA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,286-$3,240

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Innovair SHV48H2BA?
The Innovair SHV48H2BA is rated at up to 17.5 SEER2 and 12.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 15.2-17.5.
Is the Innovair SHV48H2BA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 48,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Innovair SHV48H2BA cost to run per year?
At its rated efficiency it costs about $1,286-$3,240 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,558 in Phoenix and $2,686 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Innovair SHV48H2BA the same as the NOVAIR LEA48CEN36-O?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Innovair SHV48H2BA?
ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use SAV48BDU, SAV48BDA, MMC60H2128B.
What refrigerant does the Innovair SHV48H2BA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,531/yrYou save $944/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Innovair SHV48H2BA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,531
Current system, per year
$2,475
You save per year
$944
Payback
19.1 years
Net after 10 years
-$8,564

Cooling $965Heating $566Electricity used: 9,571 kWhSaved vs. a minimum-efficiency heat pump: $367

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.