HVAC Rated

3.5-ton central heat pump · LX SERIES

York HH860E2S12

Average cooling efficiency and below average heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #25 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,362 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
40,000 BTU/h71% of its 47°F output
Excellent · beats 90%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 40,000 BTU/h at 5°F.
  • You want a choice of indoor units - 2,201 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandYork
Also sold asLuxaire, Coleman, Fraser-Johnston, CHAMPION HEATING AND COOLING, Kenmore
Outdoor unit modelHH860E2S12
SeriesLX SERIES
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 4, 2026
Last certifiedSeptember 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity43,500-54,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-8.5
Capacity at 47°F44,000-53,500 BTU/h
Capacity at 17°F40,000-45,500 BTU/h
Capacity at 5°F33,600-40,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.32
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with JHC60C5CH2SS1 at the standard test temperatures, in BTU/h:

Certified matchups2,201 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 2,201 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
JHC60C5CH2SS1-18.011.08.138,000218598222
JHC60C5CH2SS1-18.011.08.138,000218598242
JHC60C5CH2SS1-18.011.08.138,000218598239
JHC60C5CH2SS1-18.011.08.138,000218598236
JHC60C5CH2SS1-18.011.08.138,000218598228
JHC60C5CH2SS1-18.011.08.138,000218598226
JSE60D5CJ2SS1-18.011.08.139,000218641571
JHC60D5CJ2SS1-18.011.08.139,000218641570
JSC60D5CJ2SS1-18.011.08.139,000218641569
JSE60D5CJ2SS1-18.011.08.139,000218642630
JSE60D5CJ2SS1-18.011.08.139,000218642629
JSE60D5CJ2SS1-18.011.08.139,000218642627
JSE60D5CJ2SS1-18.011.08.139,000218642626
JHC60D5CJ2SS1-18.011.08.139,000218642625
JHC60D5CJ2SS1-18.011.08.139,000218642623
JHC60D5CJ2SS1-18.011.08.139,000218642621
JHC60D5CJ2SS1-18.011.08.139,000218642619
JSC60D5CJ2SS1-18.011.08.139,000218642618
JSC60D5CJ2SS1-18.011.08.139,000218642616
JSC60D5CJ2SS1-18.011.08.139,000218642615
JSC60D5CJ2SS1-18.011.08.139,000218642613
JSE60D5CJ2SS1-18.011.08.139,000218642479
JHC60D5CJ2SS1-18.011.08.139,000218642476
JSC60D5CJ2SS1-18.011.08.139,000218642473
JHC48C5CG2SS1 · cold climate-17.512.08.534,000218598223
JHC48C5CG2SS1 · cold climate-17.512.08.534,000218598243
JHC48C5CG2SS1 · cold climate-17.512.08.534,000218598240
JHC48C5CG2SS1 · cold climate-17.512.08.534,000218598231
JHC48C5CG2SS1 · cold climate-17.512.08.534,000218598229
JHC48C5CG2SS1 · cold climate-17.512.08.534,000218598227
CTF60D5CGS2+JME18D2SN2 · cold climate-17.512.08.536,000218641493
JSC48C5CG2SS1 · cold climate-17.512.08.534,000218641444
CTF60D5CGS2+JME18D2SN2 · cold climate-17.512.08.536,000218642261
CTF60D5CGS2+JME18D2SN2 · cold climate-17.512.08.536,000218642148
CTF60D5CGS2+JME18D2SN2 · cold climate-17.512.08.536,000218642146
CTF60D5CGS2+JME18D2SN2 · cold climate-17.512.08.536,000218642145
CTF60D5CGS2+JME18D2SN2 · cold climate-17.512.08.536,000218642143
JSC48C5CG2SS1 · cold climate-17.512.08.534,000218642118
JSC48C5CG2SS1 · cold climate-17.512.08.534,000218641941
JSC48C5CG2SS1 · cold climate-17.512.08.534,000218641940
JSC48C5CG2SS1 · cold climate-17.512.08.534,000218641939
JSC48C5CG2SS1 · cold climate-17.512.08.534,000218641938
CTF60D5CJS2Y81E130D20LMPS117.511.08.139,000218641582
CTF60D5CJS2Y81E130D20SMPS117.511.08.139,000218641581
CTM60D5CJS2+JMC20D2SN1-17.511.08.138,500218641576
CTF60D5CJS2+JME18D2SN2-17.511.08.138,500218641575
CTM60D5CJS2+JME18D2SN2-17.511.08.138,500218641574
CTF60D5CJS2+JMC20D2SN1-17.511.08.138,500218641573
JHE60D5CJ2SS2-17.511.08.139,000218641572
CTM60C5CGS2Y82E100C20LMPS117.512.08.134,800218641565
CTF60D5CGS2Y81E130D20LMPS117.512.08.135,200218641562
CTF60D5CGS2Y81E130D20SMPS117.512.08.135,200218641561
CTU60C5XGS2+TXVY81E080C16LMPS117.512.08.134,200218641560
CTU60C5XGS2+TXVY81E080C16SMPS117.512.08.134,200218641559
CTF60C5CGS2Y81E080C16LMPS117.512.08.134,200218641558
CTF60C5CGS2Y81E080C16SMPS117.512.08.134,200218641557
CTM60C5CGS2Y81E080C20LMPS117.512.08.134,600218641556
CTM60C5CGS2Y81E080C20SMPS117.512.08.134,600218641555
JHE48D5CG2SS2-17.512.08.134,400218641554
CTU60C5XGS2+TXVY92E100C16SMPS117.511.78.135,000218641548
Yearly running cost in 10 large cities$1,165-$3,298

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York HH860E2S12?
The York HH860E2S12 is rated at up to 18.0 SEER2 and 11.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2201 certified matchups SEER2 ranges from 15.2-18.0.
Is the York HH860E2S12 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 40,000 BTU/h at 5°F with a COP of 2.32, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
How much does the York HH860E2S12 cost to run per year?
At its rated efficiency it costs about $1,165-$3,298 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,461 in Phoenix and $2,775 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York HH860E2S12?
ENERGY STAR lists 2201 certified combinations for this outdoor unit. The highest-rated ones use JHC60C5CH2SS1, JSE60D5CJ2SS1, JHC60D5CJ2SS1.
What refrigerant does the York HH860E2S12 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,463/yrYou save $840/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York HH860E2S12
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,463
Current system, per year
$2,303
You save per year
$840
Payback
19.7 years
Net after 10 years
-$8,105

Cooling $870Heating $593Electricity used: 9,145 kWhSaved vs. a minimum-efficiency heat pump: $304

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.