HVAC Rated

3.5-ton central heat pump · LX SERIES

York HH860E2S11

Very good cooling and heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #18 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,258 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
40,500 BTU/h75% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 40,500 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandYork
Also sold asColeman, Luxaire, Fraser-Johnston, CHAMPION HEATING AND COOLING, Johnson Controls, Kenmore
Outdoor unit modelHH860E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceApril 1, 2025
Last certifiedSeptember 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 15.2-19.0)
EER2Efficiency at 95°F outdoors10.0-12.0
Cooling capacity43,500-54,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.5
Capacity at 47°F43,500-56,000 BTU/h
Capacity at 17°F31,800-39,000 BTU/h
Capacity at 5°F32,000-40,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTF60D5CGS1+JMVT20DC2N1 at the standard test temperatures, in BTU/h:

Certified matchups3,576 indoor units

The same outdoor unit scores differently with each indoor unit. The 60 highest-rated of 3,576 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
CTF60D5CGS1+JMVT20DC2N1 · cold climate19.012.09.533,800214395639
CTF60D5CGS1+JMET18DS2N1 · cold climate19.012.09.533,800214395742
CTF60D5CGS1+JMC20D2SN1 · cold climate19.012.09.534,000214395745
CTM60C5CGS1+JMVT17CC2N1 · cold climate19.012.09.533,800214395757
CTF60D5CGS1+JME18D2SN1 · cold climate19.012.09.533,800214396151
CTF60D5CGS1+JME18D2SN1 · cold climate19.012.09.533,800214397030
CTF60D5CGS1+JME18D2SN1 · cold climate19.012.09.533,800214397031
CTF60D5CGS1+JME18D2SN1 · cold climate19.012.09.533,800214397032
CTF60D5CGS1+JME18D2SN1 · cold climate19.012.09.533,800214397033
CTF60D5CGS1+JME18D2SN1 · cold climate19.012.09.533,800214397034
CTF60D5CGS1+JMVT20DC2N1 · cold climate19.012.09.533,800214397429
CTF60D5CGS1+JMVT20DC2N1 · cold climate19.012.09.533,800214397430
CTF60D5CGS1+JMVT20DC2N1 · cold climate19.012.09.533,800214397431
CTF60D5CGS1+JMVT20DC2N1 · cold climate19.012.09.533,800214397432
CTF60D5CGS1+JMVT20DC2N1 · cold climate19.012.09.533,800214397433
CTF60D5CGS1+JMET18DS2N1 · cold climate19.012.09.533,800214397839
CTF60D5CGS1+JMET18DS2N1 · cold climate19.012.09.533,800214397841
CTF60D5CGS1+JMET18DS2N1 · cold climate19.012.09.533,800214397840
CTF60D5CGS1+JMET18DS2N1 · cold climate19.012.09.533,800214397843
CTF60D5CGS1+JMET18DS2N1 · cold climate19.012.09.533,800214397842
CTF60D5CGS1+JMC20D2SN1 · cold climate19.012.09.534,000214397854
CTF60D5CGS1+JMC20D2SN1 · cold climate19.012.09.534,000214397855
CTF60D5CGS1+JMC20D2SN1 · cold climate19.012.09.534,000214397856
CTF60D5CGS1+JMC20D2SN1 · cold climate19.012.09.534,000214397857
CTF60D5CGS1+JMC20D2SN1 · cold climate19.012.09.534,000214397858
CTM60C5CGS1+JMVT17CC2N1 · cold climate19.012.09.533,800214397908
CTM60C5CGS1+JMVT17CC2N1 · cold climate19.012.09.533,800214397909
CTM60C5CGS1+JMVT17CC2N1 · cold climate19.012.09.533,800214397910
CTM60C5CGS1+JMVT17CC2N1 · cold climate19.012.09.533,800214397911
CTM60C5CGS1+JMVT17CC2N1 · cold climate19.012.09.533,800214397912
CTM60C5CGS1+JMET16CS2N1 · cold climate19.011.79.534,000214421500
CTM60C5CGS1+JMET16CS2N1 · cold climate19.011.79.534,000214421531
CTM60C5CGS1+JMET16CS2N1 · cold climate19.011.79.534,000214421532
CTM60C5CGS1+JMET16CS2N1 · cold climate19.011.79.534,000214421534
CTM60C5CGS1+JMET16CS2N1 · cold climate19.011.79.534,000214421533
CTM60C5CGS1+JMET16CS2N1 · cold climate19.011.79.534,000214421535
CTU60D5XGS1+JMET18DS2N1+TXV · cold climate19.012.09.533,800214807646
CTU60D5XGS1+JMVT20DC2N1+TXV · cold climate19.012.09.533,800214807639
CTU60D5XGS1+JMC20D2SN1+TXV · cold climate19.012.09.534,000214807640
CTU60D5XGS1+JME18D2SN1+TXV · cold climate19.012.09.533,800214807642
CTU60D5XGS1+JMET18DS2N1+TXV · cold climate19.012.09.533,800214809020
CTU60D5XGS1+JMET18DS2N1+TXV · cold climate19.012.09.533,800214809021
CTU60D5XGS1+JMET18DS2N1+TXV · cold climate19.012.09.533,800214809022
CTU60D5XGS1+JMET18DS2N1+TXV · cold climate19.012.09.533,800214809023
CTU60D5XGS1+JMET18DS2N1+TXV · cold climate19.012.09.533,800214809024
CTU60D5XGS1+JMVT20DC2N1+TXV · cold climate19.012.09.533,800214809147
CTU60D5XGS1+JMVT20DC2N1+TXV · cold climate19.012.09.533,800214809148
CTU60D5XGS1+JMVT20DC2N1+TXV · cold climate19.012.09.533,800214809149
CTU60D5XGS1+JMVT20DC2N1+TXV · cold climate19.012.09.533,800214809150
CTU60D5XGS1+JMVT20DC2N1+TXV · cold climate19.012.09.533,800214809151
CTU60D5XGS1+JMC20D2SN1+TXV · cold climate19.012.09.534,000214809152
CTU60D5XGS1+JMC20D2SN1+TXV · cold climate19.012.09.534,000214809153
CTU60D5XGS1+JMC20D2SN1+TXV · cold climate19.012.09.534,000214809154
CTU60D5XGS1+JMC20D2SN1+TXV · cold climate19.012.09.534,000214809155
CTU60D5XGS1+JMC20D2SN1+TXV · cold climate19.012.09.534,000214809156
CTU60D5XGS1+JME18D2SN1+TXV · cold climate19.012.09.533,800214809162
CTU60D5XGS1+JME18D2SN1+TXV · cold climate19.012.09.533,800214809163
CTU60D5XGS1+JME18D2SN1+TXV · cold climate19.012.09.533,800214809164
CTU60D5XGS1+JME18D2SN1+TXV · cold climate19.012.09.533,800214809165
CTU60D5XGS1+JME18D2SN1+TXV · cold climate19.012.09.533,800214809166
Yearly running cost in 10 large cities$1,114-$3,016

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York HH860E2S11?
The York HH860E2S11 is rated at up to 19.0 SEER2 and 12.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3576 certified matchups SEER2 ranges from 15.2-19.0.
Is the York HH860E2S11 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 40,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the York HH860E2S11 cost to run per year?
At its rated efficiency it costs about $1,114-$3,016 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,378 in Phoenix and $2,524 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York HH860E2S11?
ENERGY STAR lists 3576 certified combinations for this outdoor unit. The highest-rated ones use CTF60D5CGS1+JMVT20DC2N1, CTF60D5CGS1+JMET18DS2N1, CTF60D5CGS1+JMC20D2SN1.
What refrigerant does the York HH860E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,370/yrYou save $958/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York HH860E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,370
Current system, per year
$2,328
You save per year
$958
Payback
17.7 years
Net after 10 years
-$7,416

Cooling $834Heating $536Electricity used: 8,563 kWhSaved vs. a minimum-efficiency heat pump: $417

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.