3.5-ton central heat pump · INFINITY 24 HP with GREENSPEED INTELLIGENCE
Carrier 25VNA448A*031
Excellent cooling efficiency and average heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.
Ranks #7 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,262 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.0 Cooling efficiency over a seasonExcellent · beats 97%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 11.5 Cooling efficiency on a 95°F dayBelow average · beats 31%
- Heat at 5°F
- 36,400 BTU/h78% of its 47°F outputVery good · beats 83%
A good fit if…
- You want low cooling bills - its SEER2 beats 97% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 36,400 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Carrier |
| Also sold as | Bryant |
| Outdoor unit model | 25VNA448A*031 |
| Series | INFINITY 24 HP with GREENSPEED INTELLIGENCE |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | February 15, 2021 |
| Last certified | April 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.0 (range 20.5-21.0) |
| EER2Efficiency at 95°F outdoors | 11.5 |
| Cooling capacity | 43,500-44,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0 |
| Capacity at 47°F | 46,500 BTU/h |
| Capacity at 17°F | 43,500 BTU/h |
| Capacity at 5°F | 36,200-36,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.26 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CAP**4824AL*+UI at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CAP**4824AL*+UI · cold climate | 58CU*A100C21**20 | 21.0 | 11.5 | 9.0 | 36,400 | 206788945 |
| CAP**4824AL*+UI · cold climate | 59MN7C100C21**22 | 21.0 | 11.5 | 9.0 | 36,200 | 213770275 |
| CAP**4824AL*+UI · cold climate | 59TN6C100C21**22 | 21.0 | 11.5 | 9.0 | 36,200 | 213770279 |
| CAP**4821AL*+UI · cold climate | 59MN7C100C21**22 | 20.5 | 11.5 | 9.0 | 36,400 | 213770265 |
| CAP**4821AL*+UI · cold climate | 59TN6C100C21**22 | 20.5 | 11.5 | 9.0 | 36,400 | 213770267 |
| CAP**4824AL*+UI · cold climate | 59MN7C120C24**22 | 20.5 | 11.5 | 9.0 | 36,400 | 213770277 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Carrier 25VNA448A*031: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Bryant 284ANV048*0**B
Yearly running cost in 10 large cities
- Phoenix, AZ$1,281/yr
- Miami, FL$981/yr
- Houston, TX$1,151/yr
- Atlanta, GA$1,262/yr
- Los Angeles, CA$1,250/yr
- New York, NY$3,137/yr
- Chicago, IL$2,570/yr
- Denver, CO$2,155/yr
- Seattle, WA$1,339/yr
- Minneapolis, MN$2,675/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Carrier 25VNA448A*031?
- The Carrier 25VNA448A*031 is rated at up to 21.0 SEER2 and 11.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 20.5-21.0.
- Is the Carrier 25VNA448A*031 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 36,400 BTU/h at 5°F with a COP of 2.26, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
- How much does the Carrier 25VNA448A*031 cost to run per year?
- At its rated efficiency it costs about $981-$3,137 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,281 in Phoenix and $2,675 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Carrier 25VNA448A*031 the same as the Bryant 284ANV048*0**B?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Carrier 25VNA448A*031?
- ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use CAP**4824AL*+UI, CAP**4821AL*+UI.
- What refrigerant does the Carrier 25VNA448A*031 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Tempstar T5H3V48*K*AAA · cold climate23.0 SEER2 · 9.5 HSPF2
- Trane 5TWV0X48A1 · cold climate20.8 SEER2 · 10.0 HSPF2
- Tempstar B5H3V48*K*AAA · cold climate23.0 SEER2 · 9.5 HSPF2
- Lennox SL22KLV-048-230A · cold climate20.5 SEER2 · 9.8 HSPF2
- Heil H5H3V48*K*AAA · cold climate23.0 SEER2 · 9.5 HSPF2
- ECOER EODA19H-4860AA · cold climate19.5 SEER2 · 9.5 HSPF2
- Comfortmaker C5H3V48*K*AAA · cold climate23.0 SEER2 · 9.5 HSPF2
- York YZV48B2119.5 SEER2 · 8.5 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 30, 2026. How we use the data.