HVAC Rated

3.5-ton central heat pump · Evolution 23 VS Heat Pump

Bryant 293VAN048**AA

Excellent cooling efficiency and very good heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #1 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,230 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
37,400 BTU/h74% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 37,400 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandBryant
Outdoor unit model293VAN048**AA
SeriesEvolution 23 VS Heat Pump
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 20.0-23.0)
EER2Efficiency at 95°F outdoors10.0-12.5
Cooling capacity43,000-46,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.0-9.5
Capacity at 47°F48,000-48,500 BTU/h
Capacity at 17°F39,000-40,500 BTU/h
Capacity at 5°F35,600-37,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder74% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FE5BNBD60L*+UI at the standard test temperatures, in BTU/h:

Certified matchups78 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 78 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FE5BNBD60L*+UI · cold climate-23.012.59.535,600215931505
FE5BN(B,X)C48L*+UI · cold climate-22.012.09.536,000215934615
CAA**6121AM*+UI · cold climate83*CB36040C17***21.511.59.536,800215941045
CAA**6121AM*+UI · cold climate88*TB60090C21***21.511.59.036,600215934185
CAA**6121AM*+UI · cold climate935CB66100C21***21.511.59.036,600215934225
CAA**6024AM*+UI · cold climate88*TB60110C21***21.511.09.036,200215934105
CAA**6024AM*+UI · cold climate88*TB66135C24***21.511.59.036,200215934115
CAA**6124AM*+UI · cold climate987TA66100C21***21.511.09.036,800215941115
CAA**6124AM*+UI · cold climate987TA66120C24***21.511.59.036,600215941125
CAA**6124AM*+UI · cold climate986TD66120C24***21.511.59.036,800215934415
CAA**6124AM*+UI · cold climate986TD66100C21***21.511.09.036,600215934405
CAA**6124AM*+UI · cold climate987MC66100C21***21.511.09.036,600215934385
CAA**6124AM*+UI · cold climate935CB66100C21***21.511.59.036,600215934355
CAA**6124AM*+UI · cold climate88*TB66135C24***21.511.59.036,600215934335
CAA**6121AM*+UI · cold climate88*TB60110C21***21.511.09.036,800215934195
CAA**6124AM*+UI · cold climate88*TB60110C21***21.511.59.036,600215934325
CAA**6124AM*+UI · cold climate88*TB60090C21***21.511.59.036,600215934315
CAA**6121AM*+UI · cold climate83*CA60100C21***21.011.09.537,000215934135
CAA**6121AM*+UI · cold climate987MC60080C21***21.011.09.537,000215934255
CAA**6121AM*+UI · cold climate987MC66100C21***21.011.09.536,800215934265
CAA**6124AM*+UI · cold climate83*CA60100C21***21.011.09.536,800215934295
CAA**6024AM*+UI · cold climate83*CA60100C21***21.011.09.536,400215934085
CAA**4821AM*+UI · cold climate83*CB36040C17***21.011.09.536,400215940945
CAA**4821AM*+UI · cold climate83*CB48060C17***21.011.09.536,600215940955
CAA**6024AM*+UI · cold climate935CB60080C21***21.011.09.036,600215934125
CAA**6121AM*+UI · cold climate935CB60080C21***21.011.09.037,000215934215
CAA**6121AM*+UI · cold climate986TD66100C21***21.011.09.036,800215934285
CAA**4821AM*+UI · cold climate935CB66100C21***21.011.09.036,200215934035
CAA**4821AM*+UI · cold climate88*TB60090C21***21.011.09.036,200215934005
CAA**4821AM*+UI · cold climate88*TB60110C21***21.011.09.036,400215934015
CAA**6024AM*+UI · cold climate88*TB60070C21***21.011.09.036,600215934095
CAA**6024AM*+UI · cold climate986TD60080C21***21.011.09.036,600215940995
CAA**6024AM*+UI · cold climate987TA60080C21***21.011.09.036,600215941005
CAA**6024AM*+UI · cold climate987TA66100C21***21.011.09.036,400215941015
CAA**6024AM*+UI · cold climate987TA66120C24***21.011.09.036,400215941025
CAA**6121AM*+UI · cold climate986TD60080C21***21.011.09.037,000215941035
CAA**6121AM*+UI · cold climate83*CB48060C17***21.011.59.037,000215941055
CAA**6121AM*+UI · cold climate987TA60080C21***21.011.09.037,000215941075
CAA**6121AM*+UI · cold climate987TA66100C21***21.011.09.036,800215941085
CAA**6124AM*+UI · cold climate986TD60080C21***21.011.09.037,000215941095
CAA**6124AM*+UI · cold climate987TA60080C21***21.011.09.037,000215941105
CAA**4821AM*+UI · cold climate987TA66100C21***21.010.59.036,400215940985
CAA**6124AM*+UI · cold climate987MC66120C24***21.011.09.036,800215934395
CAA**6124AM*+UI · cold climate88*TB60070C21***21.011.09.037,000215934305
CAA**6124AM*+UI · cold climate987MC60080C21***21.011.09.036,800215934375
CAA**6124AM*+UI · cold climate935CB60080C21***21.011.09.036,800215934345
CAA**6121AM*+UI · cold climate88*TB60070C21***21.011.09.037,000215934165
CAA**4821AM*+UI · cold climate83*CA60100C21***20.510.59.536,600215933975
CAA**6124AM*+UI · cold climate987MC60060C21***20.510.59.537,400215934365
CAA**4821AM*+UI · cold climate987MC60080C21***20.510.59.536,600215934065
CAA**4821AM*+UI · cold climate987TA60080C21***20.510.59.536,600215940975
CAA**4821AM*+UI · cold climate986TD60080C21***20.510.59.536,600215940935
CAA**6121AM*+UI · cold climate987MC60060C21***20.510.09.437,400215934235
CSAH*4812AM*+UI · cold climate88*TB66135C24***20.511.09.036,400215934475
CSAH*4812AM*+UI · cold climate88*TB60090C21***20.511.09.036,400215934455
CSAH*4812AM*+UI · cold climate88*TB60110C21***20.511.09.036,400215934465
CSAH*6012AM*+UI · cold climate83*CA60100C21***20.511.09.036,600215934545
CSAH*6012AM*+UI · cold climate935CB66100C21***20.511.59.036,400215934585
CAA**4821AM*+UI · cold climate935CB60080C21***20.510.59.036,600215934025
CAA**4821AM*+UI · cold climate88*TB60070C21***20.510.59.036,600215933995
Yearly running cost in 10 large cities$929-$3,078

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Bryant 293VAN048**AA?
The Bryant 293VAN048**AA is rated at up to 23.0 SEER2 and 12.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 78 certified matchups SEER2 ranges from 20.0-23.0.
Is the Bryant 293VAN048**AA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 37,400 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Bryant 293VAN048**AA cost to run per year?
At its rated efficiency it costs about $929-$3,078 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,227 in Phoenix and $2,635 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Bryant 293VAN048**AA?
ENERGY STAR lists 78 certified combinations for this outdoor unit. The highest-rated ones use FE5BNBD60L*+UI, FE5BN(B,X)C48L*+UI, CAA**6121AM*+UI.
What refrigerant does the Bryant 293VAN048**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,260/yrYou save $1,117/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant 293VAN048**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,260
Current system, per year
$2,378
You save per year
$1,117
Payback
15.2 years
Net after 10 years
-$5,829

Cooling $689Heating $572Electricity used: 7,878 kWhSaved vs. a minimum-efficiency heat pump: $571

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.