3.5-ton central heat pump · QUIETCOMFORT DELUXE 23 VS HP

Heil H5H3V48*K*AAA

Excellent cooling efficiency and very good heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #4 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,230 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
38,500 BTU/h74% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 38,500 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, ACIQ
Outdoor unit modelH5H3V48*K*AAA
SeriesQUIETCOMFORT DELUXE 23 VS HP
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 19.5-23.0)
EER2Efficiency at 95°F outdoors10.0-12.5
Cooling capacity43,000-46,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-9.5
Capacity at 47°F48,000-53,500 BTU/h
Capacity at 17°F39,000-43,500 BTU/h
Capacity at 5°F35,600-38,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder74% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups539 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 539 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FCMA5B60L0D*+WALLCON · cold climate-23.012.59.535,600215931506
FCMA5B60L0D*+WALLCON · cold climate-23.012.59.535,600215931507
FCMA5B60L0D*+WALLCON · cold climate-23.012.59.535,600215931508
FCMA5B60L0D*+WALLCON · cold climate-23.012.59.535,600216635232
FCMA5B48L0C*+WALLCON · cold climate-22.012.09.536,000215934616
FCMA5B48L0C*+WALLCON · cold climate-22.012.09.536,000215934617
FCMA5B48L0C*+WALLCON · cold climate-22.012.09.536,000215934618
FCMA5B48L0C*+WALLCON · cold climate-22.012.09.536,000216635543
EA*5X61M21A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934186
EA*5X61M21A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934187
EA*5X61M21A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934188
EA*5X61M21A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934226
EA*5X61M21A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934228
EA*5X61M21A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934227
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,200215934106
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,200215934107
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,200215934108
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,200215934116
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,200215934118
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,200215934117
EA*5X61M21A*+WALLCON · cold climate*80CSU0401712B*21.511.59.536,800215941046
EA*5X61M21A*+WALLCON · cold climate*80CSU0401712B*21.511.59.536,800215941047
EA*5X61M21A*+WALLCON · cold climate*80CSU0401712B*21.511.59.536,800215941048
EA*5X61M24A*+WALLCON · cold climate*97CTN1002122A*21.511.09.536,800215941116
EA*5X61M24A*+WALLCON · cold climate*97CTN1002122A*21.511.09.536,800215941117
EA*5X61M24A*+WALLCON · cold climate*97CTN1002122A*21.511.09.536,800215941118
EA*5X61M24A*+WALLCON · cold climate*97CTN1202422A*21.511.59.536,600215941127
EA*5X61M24A*+WALLCON · cold climate*97CTN1202422A*21.511.59.536,600215941126
EA*5X61M24A*+WALLCON · cold climate*97CTN1202422A*21.511.59.536,600215941128
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,200216635493
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,200216635492
EA*5X61M21A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600216635500
EA*5X61M21A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600216635504
EA*5X61M21A*+WALLCON · cold climate*80CSU0401712B*21.511.59.536,800216636186
EA*5X61M24A*+WALLCON · cold climate*97CTN1002122A*21.511.09.536,800216636193
EA*5X61M24A*+WALLCON · cold climate*97CTN1202422A*21.511.59.536,600216636194
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*21.511.59.536,800215934416
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*21.511.59.536,800215934417
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*21.511.59.536,800215934418
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*21.511.09.536,600215934406
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*21.511.09.536,600215934407
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*21.511.09.536,600215934408
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*21.511.09.536,600215934386
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*21.511.09.536,600215934387
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*21.511.09.536,600215934388
EA*5X61M24A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934356
EA*5X61M24A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934357
EA*5X61M24A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934358
EA*5X61M21A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,800215934196
EA*5X61M21A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,800215934197
EA*5X61M21A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,800215934198
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,600215934336
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,600215934337
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,600215934338
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*21.511.59.536,600215934326
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*21.511.59.536,600215934327
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*21.511.59.536,600215934328
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934316
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934318
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934317
Yearly running cost in 10 large cities$929-$3,078

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Heil H5H3V48*K*AAA?
The Heil H5H3V48*K*AAA is rated at up to 23.0 SEER2 and 12.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 539 certified matchups SEER2 ranges from 19.5-23.0.
Is the Heil H5H3V48*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 38,500 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Heil H5H3V48*K*AAA cost to run per year?
At its rated efficiency it costs about $929-$3,078 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,227 in Phoenix and $2,635 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Heil H5H3V48*K*AAA?
ENERGY STAR lists 539 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, FCMA5B48L0C*+WALLCON, EA*5X61M21A*+WALLCON.
What refrigerant does the Heil H5H3V48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,260/yrYou save $1,117/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H3V48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,260
Current system, per year
$2,378
You save per year
$1,117
Payback
15.2 years
Net after 10 years
-$5,829

Cooling $689Heating $572Electricity used: 7,878 kWhSaved vs. a minimum-efficiency heat pump: $571

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.