4-ton central heat pump · ATOM X
Midea MDV-V60WMN10T
Excellent cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #18 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,409 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.5 Cooling efficiency over a seasonExcellent · beats 91%
- HSPF2
- 10.1 Heating efficiency over a seasonExcellent · beats 90%
- EER2
- 9.5 Cooling efficiency on a 95°F dayBelow average · beats 5%
- Heat at 5°F
- 45,000 BTU/h70% of its 47°F outputBelow average · beats 27%
A good fit if…
- You want low cooling bills - its SEER2 beats 91% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 45,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 90% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Midea |
| Outdoor unit model | MDV-V60WMN10T |
| Series | ATOM X |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 15, 2024 |
| Last certified | April 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.5 (range 16.0-19.5) |
| EER2Efficiency at 95°F outdoors | 9.0-10.1 |
| Cooling capacity | 52,000-60,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.9-10.1 |
| Capacity at 47°F | 54,000-60,000 BTU/h |
| Capacity at 17°F | 38,000-42,000 BTU/h |
| Capacity at 5°F | 42,000-45,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.95 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| - MIDEA · cold climate | - | 19.5 | 9.5 | 10.1 | 42,000 | 216021081 |
| - MIDEA · cold climate | - | 18.3 | 9.5 | 9.7 | 42,000 | 216021082 |
| MIH54VMN10 · cold climate | - | 17.0 | 10.1 | 9.3 | 45,000 | 216441719 |
| - MIDEA · cold climate | - | 17.0 | 9.0 | 9.2 | 42,000 | 216021062 |
| MVME60C2MN10TB · cold climate | - | 16.0 | 10.0 | 9.3 | 45,000 | 216051346 |
| MCPM4860CN10TH · cold climate | MGV96U100C5C | 16.0 | 10.0 | 8.9 | 45,000 | 216054431 |
| MCPM4860DN10TH · cold climate | MGV96U100D5C | 16.0 | 10.0 | 8.9 | 45,000 | 216046596 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,548/yr
- Miami, FL$1,253/yr
- Houston, TX$1,388/yr
- Atlanta, GA$1,409/yr
- Los Angeles, CA$1,372/yr
- New York, NY$3,372/yr
- Chicago, IL$2,739/yr
- Denver, CO$2,278/yr
- Seattle, WA$1,400/yr
- Minneapolis, MN$2,820/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Midea MDV-V60WMN10T?
- The Midea MDV-V60WMN10T is rated at up to 19.5 SEER2 and 9.5 EER2 for cooling and up to 10.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 7 certified matchups SEER2 ranges from 16.0-19.5.
- Is the Midea MDV-V60WMN10T good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 45,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Midea MDV-V60WMN10T cost to run per year?
- At its rated efficiency it costs about $1,253-$3,372 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,548 in Phoenix and $2,820 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Midea MDV-V60WMN10T?
- ENERGY STAR lists 7 certified combinations for this outdoor unit. The highest-rated ones use MIH54VMN10, MVME60C2MN10TB, MCPM4860CN10TH.
- What refrigerant does the Midea MDV-V60WMN10T use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Bosch BOHA-60MTB-M18S · cold climate19.5 SEER2 · 10.1 HSPF2
- SAMYOU VUH60-VA6BA(0) · cold climate19.6 SEER2 · 10.8 HSPF2
- ACIQ B5H0V48*K*AAA · cold climate19.5 SEER2 · 9.5 HSPF2
- Trane 4TWV0X48A120.0 SEER2 · 8.7 HSPF2
- ACIQ H5H0V48*K*AAA · cold climate19.5 SEER2 · 9.5 HSPF2
- TOSOT TU60W-GDU20.0 SEER2 · 9.5 HSPF2
- Carrier 27VNA048A*030 · cold climate19.5 SEER2 · 9.5 HSPF2
- GREE WLUD48W2/NHG-D(U)20.0 SEER2 · 9.5 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 17, 2026. How we use the data.