HVAC Rated

4-ton central heat pump · ATOM X

Midea MDV-V60WMN10T

Excellent cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #18 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,409 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
10.1 Heating efficiency over a season
Excellent · beats 90%
EER2
9.5 Cooling efficiency on a 95°F day
Below average · beats 5%
Heat at 5°F
45,000 BTU/h70% of its 47°F output
Below average · beats 27%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 45,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 90% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandMidea
Outdoor unit modelMDV-V60WMN10T
SeriesATOM X
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 15, 2024
Last certifiedApril 17, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 16.0-19.5)
EER2Efficiency at 95°F outdoors9.0-10.1
Cooling capacity52,000-60,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.9-10.1
Capacity at 47°F54,000-60,000 BTU/h
Capacity at 17°F38,000-42,000 BTU/h
Capacity at 5°F42,000-45,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.95
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups7 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
- MIDEA · cold climate-19.59.510.142,000216021081
- MIDEA · cold climate-18.39.59.742,000216021082
MIH54VMN10 · cold climate-17.010.19.345,000216441719
- MIDEA · cold climate-17.09.09.242,000216021062
MVME60C2MN10TB · cold climate-16.010.09.345,000216051346
MCPM4860CN10TH · cold climateMGV96U100C5C16.010.08.945,000216054431
MCPM4860DN10TH · cold climateMGV96U100D5C16.010.08.945,000216046596
Yearly running cost in 10 large cities$1,253-$3,372

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Midea MDV-V60WMN10T?
The Midea MDV-V60WMN10T is rated at up to 19.5 SEER2 and 9.5 EER2 for cooling and up to 10.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 7 certified matchups SEER2 ranges from 16.0-19.5.
Is the Midea MDV-V60WMN10T good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 45,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Midea MDV-V60WMN10T cost to run per year?
At its rated efficiency it costs about $1,253-$3,372 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,548 in Phoenix and $2,820 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Midea MDV-V60WMN10T?
ENERGY STAR lists 7 certified combinations for this outdoor unit. The highest-rated ones use MIH54VMN10, MVME60C2MN10TB, MCPM4860CN10TH.
What refrigerant does the Midea MDV-V60WMN10T use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,537/yrYou save $1,176/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Midea MDV-V60WMN10T
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,537
Current system, per year
$2,714
You save per year
$1,176
Payback
16.6 years
Net after 10 years
-$7,735

Cooling $939Heating $599Electricity used: 9,609 kWhSaved vs. a minimum-efficiency heat pump: $549

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 17, 2026. How we use the data.