American Standard 4A6V0X60A1

Excellent cooling efficiency and below average heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #25 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,547 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
40,000 BTU/h73% of its 47°F output
Below average · beats 9%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 40,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 86 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandAmerican Standard
Outdoor unit model4A6V0X60A1
SeriesPLATINUM 20
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2023
Last certifiedJuly 24, 2025
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 19.0-19.5)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity52,500-54,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F50,000-53,500 BTU/h
Capacity at 17°F48,000-51,000 BTU/h
Capacity at 5°F37,000-40,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.60-1.84
ENERGY STAR cold climateYes
Heating output as it gets colder73% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TEM8B0C60V51+TDR at the standard test temperatures, in BTU/h:

Certified matchups86 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 86 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TEM8B0C60V51+TDR-19.512.08.537,000207820993
TEM8A0C48V41+TDR-19.512.08.537,000207709026
4PX*DU60BS3+P0V0D000M50SC+RP-19.512.08.239,000207805675
4TXCD010DS3+P0V0D000M50SC+RP-19.512.08.239,000207805681
4PX*CU60BS3+P0V0C000M50SD+RP-19.512.08.239,000212629894
4PX*DD60BS3+P0V0D000M50SD+RP-19.512.08.239,500212629898
4TXCD008DS3+P0V0D000M50SD+RP-19.512.08.239,500212629910
4TXCC009DS3+P0V0C000M50SD+RP-19.512.08.239,000212629906
4PX*DU60BS3+P0V0D000M50SD+RP-19.512.08.239,000212621478
4TXCD010DS3+P0V0D000M50SD+RP-19.512.08.239,000212621480
4PX*DU60BS3S9V2D120U5VSB+RP19.512.08.239,500214638870
4TXCD010DS3S9V2D120U5VSB+RP19.512.08.239,500214638874
4PX*DU60BS3S9V2D120U5PSC+RP19.512.08.238,500214639560
4TXCD010DS3S9V2D120U5PSC+RP19.512.08.238,500214639574
4PX*DU60BS3S9V2D120U5VSA+RP19.512.08.239,500207590162
4TXCD010DS3S9V2D120U5VSA+RP19.512.08.239,500207590164
4PX*CU60BS3+P0V0C000M50SC+RP-19.512.08.239,000207805672
4TXCD008DS3+P0V0D000M50SC+RP-19.512.08.239,500207805679
4PX*DD60BS3+P0V0D000M50SC+RP-19.512.08.239,500207805673
4TXCC009DS3+P0V0C000M50SC+RP-19.512.08.239,000207805678
4TXCD010DS3S9V2D120U5PSB+RP19.512.08.239,500208185424
4PX*DU60BS3S9V2D120U5PSB+RP19.512.08.239,500210653077
4TXCD008DS3S9V2D120U5VSA+RP19.511.78.140,000210653083
4TXCD008DS3S9V2D120U5PSB+RP19.511.78.140,000210653082
4PX*CD60BS3+P0V0C000M50SC+RP-19.512.08.039,500207805670
4TXCD010DS3S8V2D120M5PDA19.011.78.239,500211081440
4PX*DU60BS3S8V2D120M5PDA19.011.78.239,500211081436
4PX*CU60BS3 · cold climateS8V2C100M5PDA19.011.78.240,000211081434
4TXCC009DS3 · cold climateS8V2C100M5PDA19.011.78.240,000211081438
4TXCD010DS3S8V2D120M5PCA19.011.78.239,500210692079
4PX*CU60BS3 · cold climateS8V2C100M5PCA19.011.78.240,000210692073
4PX*DU60BS3S8V2D120M5PCA19.011.78.239,500210692076
4TXCC009DS3 · cold climateS8V2C100M5PCA19.011.78.240,000210692077
4PX*CU60BS3L8V1C100U5VSB+RP19.011.78.239,500212629896
4TXCC009DS3L8V1C100U5VSB+RP19.011.78.239,500212629908
TAMXB0C60V51-19.012.08.239,500210929580
4PX*CU60BS3S9V2C080U5PSC+RP19.011.78.239,500214639548
4TXCC009DS3S9V2C100U5PSC+RP19.011.78.239,500214639564
4TXCC009DS3S9V2C080U5PSC+RP19.011.78.239,500214639566
4TXCD010DS3 · cold climate*UHMD120CCV519.011.78.239,000214250708
4PX*DU60BS3 · cold climateS8V2D120M5PCB19.011.78.239,500214253214
4PX*DU60BS3 · cold climateS8V2D120M5PDB19.011.78.239,500214253212
4TXCD010DS3 · cold climateS8V2D120M5PCB19.011.78.239,500214253220
4TXCD010DS3 · cold climateS8V2D120M5PDB19.011.78.239,500214253222
TEM6A0C48H41+TDR+RP-19.011.78.238,500215429061
4PX*CU60BS3L8V1C100U5VSA+RP19.011.78.239,500207590612
4TXCC009DS3L8V1C100U5VSA+RP19.011.78.239,500207590613
4TXCC009DS3S9V2C100U5PSB+RP19.011.78.239,500208185423
4TXCC009DS3S9V2C080U5PSB+RP19.011.78.239,500208185422
4TXCD010DS3S9V2C080U5VSB+RP19.011.88.239,500215825754
4PX*CU60BS3S9V2C080U5VSB+RP19.011.78.239,500215825740
4PX*CU60BS3S9V2C100U5VSB+RP19.011.88.239,500215825742
4PX*DU60BS3S9V2C080U5VSB+RP19.011.88.239,500215825746
4PX*DU60BS3S9V2C100U5VSB+RP19.011.98.239,500215825748
4TXCC009DS3S9V2C100U5VSB+RP19.011.88.239,500215825750
4TXCC009DS3S9V2C080U5VSB+RP19.011.78.239,500215825752
4TXCD010DS3S9V2C100U5VSB+RP19.011.98.239,500215825756
4PX*CU60BS3S9V2C100U5PSB+RP19.011.78.239,500210653073
4PX*CU60BS3S9V2C080U5PSB+RP19.011.78.239,500210653074
4PX*DU60BS3L8V1C100U5VSB+RP19.012.08.138,000212629900
Yearly running cost in 10 large cities$1,306-$3,760

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the American Standard 4A6V0X60A1?
The American Standard 4A6V0X60A1 is rated at up to 19.5 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 86 certified matchups SEER2 ranges from 19.0-19.5.
Is the American Standard 4A6V0X60A1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 40,000 BTU/h at 5°F with a COP of 1.84, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the American Standard 4A6V0X60A1 cost to run per year?
At its rated efficiency it costs about $1,306-$3,760 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,647 in Phoenix and $3,171 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the American Standard 4A6V0X60A1?
ENERGY STAR lists 86 certified combinations for this outdoor unit. The highest-rated ones use TEM8B0C60V51+TDR, TEM8A0C48V41+TDR, 4PX*DU60BS3+P0V0D000M50SC+RP.
What refrigerant does the American Standard 4A6V0X60A1 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,653/yrYou save $1,090/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump American Standard 4A6V0X60A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,653
Current system, per year
$2,743
You save per year
$1,090
Payback
18.8 years
Net after 10 years
-$9,599

Cooling $975Heating $679Electricity used: 10,333 kWhSaved vs. a minimum-efficiency heat pump: $445

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 24, 2025. How we use the data.