HVAC Rated

4-ton central heat pump · PLATINUM 17

American Standard 4A6V7X48A1

Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #159 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,391 a year to run in a mixed climate like Atlanta.

SEER2
17.1 Cooling efficiency over a season
Average · beats 53%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
28,800 BTU/h58% of its 47°F output
Below average · beats 20%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 129 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandAmerican Standard
Outdoor unit model4A6V7X48A1
SeriesPLATINUM 17
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceApril 25, 2024
Last certifiedJuly 9, 2025
Cooling
SEER2Seasonal efficiency, higher is better17.1 (range 17.0-17.1)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity44,000-47,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-8.5
Capacity at 47°F40,000-48,000 BTU/h
Capacity at 17°F35,200-37,600 BTU/h
Capacity at 5°F27,400-28,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.70-1.90
ENERGY STAR cold climateNo
Heating output as it gets colder58% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TAMXB0C60V51 at the standard test temperatures, in BTU/h:

Certified matchups129 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 129 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TAMXB0C60V51-17.112.08.527,800212391555
TAMXB0C48V41-17.111.78.528,000212391376
TAMXB0C42V41-17.111.78.527,800212391554
4PX*CD60BS3S9V2C100D5PSB+LRP17.111.78.528,400213826606
4PX*CD60BS3S9V2C100D4VSB+LRP17.111.78.528,400213826608
4PX*CD60BS3S9V2C100D4VSA+LRP17.111.78.528,400213826610
4PX*CD60BS3S9V2C100D5PSC+LRP17.111.78.528,400213826612
4PX*CU42BS3L8V1C100U5VSB+LRP17.111.78.528,800213826614
4PX*CU48BS3L8V1C100U5VSB+LRP17.111.78.528,800213826616
4PX*CU48BS3*UHMC100CCV4+LRP17.111.78.528,600213826618
4PX*CU48BS3*UHMC100ACV4+LRP17.111.78.528,600213826620
4PX*CU60BS3*UHMC100ACV4+LRP17.112.08.528,200213826622
4PX*CU60BS3*UHMC100CCV4+LRP17.112.08.528,200213826624
4PX*CU60BS3L8V1C100U5VSB+LRP17.112.08.528,400213826626
4TXCD010DS3S9V2C100U5PSC+LRP17.111.78.527,600213826722
4PX*DU48BS3L8V1C100U5VSB+LRP17.111.78.527,800213826644
4PX*DU48BS3*UHMC100CCV4+LRP17.111.78.527,800213826646
4PX*DU48BS3S9V2C100U5PSC+LRP17.111.78.528,000213826648
4PX*DU48BS3S9V2C100U5PSB+LRP17.111.78.528,000213826650
4PX*DU48BS3*UHMC100ACV4+LRP17.111.78.527,800213826652
4PX*DU60BS3S9V2C080U5PSC+LRP17.111.78.527,600213826654
4PX*DU60BS3S9V2C080U5PSB+LRP17.111.78.527,600213826656
4PX*DU60BS3*UHMD120CCV5+LRP17.112.08.528,200213826660
4TXCD010DS3S9V2C080U5PSB+LRP17.111.78.527,600213826724
4PX*DU60BS3L8V1C100U5VSB+LRP17.112.08.527,400213826658
4PX*DU60BS3*UHMD120ACV5+LRP17.112.08.528,200213826662
4TXCD010DS3S9V2C080U5PSC+LRP17.111.78.527,600213826726
4TXCD010DS3S9V2C100U4VSA+LRP17.111.78.527,400213826728
4TXCD010DS3S9V2C100U4VSB+LRP17.111.78.527,400213826730
4TXCD010DS3S9V2C100U5PSB+LRP17.111.78.527,600213826732
4TXCD010DS3*UHMC100ACV4+LRP17.112.08.527,400213826734
4TXCC009DS3S9V2C100U4VSA+LRP17.111.78.528,400213826692
4TXCC009DS3S9V2C080U5PSB+LRP17.111.78.528,600213826696
4TXCC009DS3S9V2C080U5PSC+LRP17.111.78.528,600213826694
4TXCC009DS3S9V2C100U5PSB+LRP17.111.78.528,600213826698
4TXCD008DS3S9V2C100U5PSC+LRP17.111.78.528,000213826700
4TXCD008DS3L8V1C100U5VSB+LRP17.111.78.527,800213826704
4TXCD008DS3S9V2C100U5PSB+LRP17.111.78.528,000213826702
4TXCD008DS3*UHMD120CCV5+LRP17.111.78.528,600213826706
4TXCD008DS3*UHMD120ACV5+LRP17.111.78.528,600213826708
4TXCD008DS3*UHMC100CCV4+LRP17.111.78.527,800213826710
4PX*CU60BS3S9V2C080U5PSC+LRP17.111.78.528,600213826630
4PX*CU60BS3S9V2C080U5PSB+LRP17.111.78.528,600213826628
4PX*CU60BS3S9V2C100U5PSB+LRP17.111.78.528,600213826636
4PX*CU60BS3S9V2C100U4VSA+LRP17.111.78.528,400213826632
4PX*CU60BS3S9V2C100U4VSB+LRP17.111.78.528,400213826634
4PX*DU48BS3*UHMD120ACV5+LRP17.111.78.528,600213826640
4PX*CU60BS3S9V2C100U5PSC+LRP17.111.78.528,600213826638
4PX*DU48BS3*UHMD120CCV5+LRP17.111.78.528,600213826642
4PX*DU60BS3*UHMC100ACV4+LRP17.112.08.527,400213826666
4PX*DU60BS3*UHMC100CCV4+LRP17.112.08.527,400213826664
4PX*DU60BS3S9V2C100U5PSC+LRP17.111.78.527,600213826668
4PX*DU60BS3S9V2C100U4VSA+LRP17.111.78.527,400213826670
4TXCC007DS3*UHMC100CCV4+LRP17.111.78.528,600213826678
4TXCC007DS3L8V1C100U5VSB+LRP17.111.78.528,800213826676
4PX*DU60BS3S9V2C100U4VSB+LRP17.111.78.527,400213826672
4PX*DU60BS3S9V2C100U5PSB+LRP17.111.78.527,600213826674
4TXCC007DS3*UHMC100ACV4+LRP17.111.78.528,600213826680
4TXCC009DS3*UHMC100ACV4+LRP17.112.08.528,200213826684
4TXCC009DS3*UHMC100CCV4+LRP17.112.08.528,200213826682
Yearly running cost in 10 large cities$1,276-$3,298

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the American Standard 4A6V7X48A1?
The American Standard 4A6V7X48A1 is rated at up to 17.1 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 129 certified matchups SEER2 ranges from 17.0-17.1.
Is the American Standard 4A6V7X48A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the American Standard 4A6V7X48A1 cost to run per year?
At its rated efficiency it costs about $1,276-$3,298 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,557 in Phoenix and $2,743 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the American Standard 4A6V7X48A1?
ENERGY STAR lists 129 certified combinations for this outdoor unit. The highest-rated ones use TAMXB0C60V51, TAMXB0C48V41, TAMXB0C42V41.
What refrigerant does the American Standard 4A6V7X48A1 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,537/yrYou save $820/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump American Standard 4A6V7X48A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,537
Current system, per year
$2,357
You save per year
$820
Payback
21.3 years
Net after 10 years
-$9,302

Cooling $957Heating $580Electricity used: 9,606 kWhSaved vs. a minimum-efficiency heat pump: $265

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 9, 2025. How we use the data.